Hostname: page-component-848d4c4894-xfwgj Total loading time: 0 Render date: 2024-06-24T18:09:17.288Z Has data issue: false hasContentIssue false

Treatment of flat and hollow substrates by a pure nitrogen flowing post discharge

Application to bacterial decontamination in low diameter tubes

Published online by Cambridge University Press:  19 December 2007

S. Villeger*
Affiliation:
PRHE Team, Laboratoire Plasma et Conversion d'Énergie (LAPLACE), UMR CNRS 5213, Université Paul Sabatier,118 Route de Narbonne, 31062 Toulouse Cedex 9, France
J. P. Sarrette
Affiliation:
PRHE Team, Laboratoire Plasma et Conversion d'Énergie (LAPLACE), UMR CNRS 5213, Université Paul Sabatier,118 Route de Narbonne, 31062 Toulouse Cedex 9, France
B. Rouffet
Affiliation:
PRHE Team, Laboratoire Plasma et Conversion d'Énergie (LAPLACE), UMR CNRS 5213, Université Paul Sabatier,118 Route de Narbonne, 31062 Toulouse Cedex 9, France
S. Cousty
Affiliation:
PRHE Team, Laboratoire Plasma et Conversion d'Énergie (LAPLACE), UMR CNRS 5213, Université Paul Sabatier,118 Route de Narbonne, 31062 Toulouse Cedex 9, France
A. Ricard
Affiliation:
PRHE Team, Laboratoire Plasma et Conversion d'Énergie (LAPLACE), UMR CNRS 5213, Université Paul Sabatier,118 Route de Narbonne, 31062 Toulouse Cedex 9, France
Get access

Abstract

Recently, the bactericidal efficiency of a low-pressure plasma process using a pure N2 flowing post discharge was demonstrated [Eur. Phys. J. Appl. Phys. 34, 143 (2006)]. In order to use this process for the decontamination of medical fiberscopes and endoscopes and more generally for the industrial decontamination of hollow bodies, the ability of the nitrogen atoms (which are believed to be the main decontamination agent) to flow in low diameter tubes (between 2 and 8 mm i.d.) without massive destruction is checked. The dependence of the N-atom concentration with the length, the internal diameter and the material of the tubes is studied and quantified. It is shown that the N-atom concentrations measured at the outlet of a polyamide tube of 6 m in length and of a 0.2 m long stainless steel tube are sufficient enough to provide high inactivation levels.

Keywords

Type
Research Article
Copyright
© EDP Sciences, 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Oseguera, J., Castillo, F., Gomez, A., Fraguela, A.., Thin Solid Films 515, 1197 (2006) CrossRef
Guymont, O., LeDuc, E., Pagnon, D., Pointu, A.M., Touzeau, M., Vialle, M., Mercey, B., Murray, H., Plasma Sources Sci. Technol. 1, 175 (1992) CrossRef
Normand, F., Marec, J., Leprince, P., Granier, A., Mater. Sci. Eng. A 139, 103 (1991) CrossRef
Moisan, M., Barbeau, J., Moreau, S., Pelletier, J., Tabrizian, M., L'.H. Yahia, Int. J. Pharmaceut. 226, 1 (2001) CrossRef
Villeger, S., Sarrette, J.P., Ricard, A., Plasma Process. Polym. 2, 709 (2005) CrossRef
Luu Du, D.c, J. Shum Cheong Sing, M.R. Mallaret, H. Soule, A. Arnaud, J. Croizé, J. Calop, Med. Mal. Infect. 26, 99 (1996)
Laroussi, M., IEEE Trans. Plasma Sci. 30, 1409 (2002) CrossRef
Cousty, S., Villeger, S., Sarrette, J.P., Ricard, A., Sixou, M., Eur. Phys. J. Appl. Phys. 34, 143 (2006) CrossRef
Boudam, M.K., Saoudi, B., Moisan, M., Ricard, A., J. Phys. D: Appl. Phys. 40, 1694 (2007) CrossRef
Blanchard, H., Sarrette, J.P., Villeger, S., Baudel, P., Ricard, A., Eur. Phys. J. Appl. Phys. 26, 221 (2004) CrossRef
O.E. Krivonosova, S.A. Losev, V.P. Nalivaiko, Yu.K. Mukoseev, O.P. Shatalov, in Reviews of Plasma Chemistry, edited by B.M. Smirnov (Consultants Bureau, New York and London, 1991), Vol. 1
T. Yamashita, J. Chem. Phys. 70, 4248 (1979)
Belmonte, T., Lefèvre, L., Czerwiec, T., Michel, H., Ricard, A., Thin Solid Films 341, 27 (1999) CrossRef
Adams, S.F., Miller, T.A., Plasma Sources Sci. Technol. 9, 248 (2000) CrossRef
Sarrette, J.P., Rouffet, B., Ricard, A., Plasma Process. Polym. 3, 120 (2006) CrossRef
Bockel, S., Diamy, A.M., Ricard, A., Surf. Coat. Technol. 74-5, 474 (1995) CrossRef