Study of the arc behavior in low-voltage circuit breaker by means of optical and magnetic measurements

Published online by Cambridge University Press:  22 December 2009

C. Brdys*
Affiliation:
Laboratoire d'Électrotechnique de Montluçon, Campus F. Mitterrand, Avenue Aristide Briand, 03100 Montluçon, France
D. Cajal
Affiliation:
Laboratoire d'Électrotechnique de Montluçon, Campus F. Mitterrand, Avenue Aristide Briand, 03100 Montluçon, France
J.-P. Toumazet
Affiliation:
Laboratoire d'Électrotechnique de Montluçon, Campus F. Mitterrand, Avenue Aristide Briand, 03100 Montluçon, France
F. Gary
Affiliation:
Laboratoire d'Électrotechnique de Montluçon, Campus F. Mitterrand, Avenue Aristide Briand, 03100 Montluçon, France
A. Laurent
Affiliation:
Laboratoire d'Électrotechnique de Montluçon, Campus F. Mitterrand, Avenue Aristide Briand, 03100 Montluçon, France
C. Arnoux
Affiliation:
Schneider Electric Industries, 37 quai Paul-Louis Merlin, 38050 Grenoble Cedex 9, France
Get access

Abstract

The presented study deals with the influence of the contacts materials on the evolution of the arc in low voltage circuit breakers. The commutation from the mobile contact onto the electrode is especially investigated in order to improve the breaking device performances. Hence, to preserve the qualities of the contact, the arc must leave this area as soon as possible. To undertake this study, several diagnostics are implemented. A measuring device is composed of magnetic induction sensors located outside the chamber. It allows the determination of the position and the volume of the arc during the breaking. Optical (ultra-speed camera) and electrical measurements are also performed with the technical support of Schneider Electric. Different current values (assumed peak current of 3 kA, 8 kA and 12 kA) and different natures of materials composing the electrical contacts have been tested. Copper contacts, different contacts on silver base obtained with different processes have been used. Experimental results show the influence of these various parameters on the arc volume and on the transfer of the arc towards the quenching chamber. Indeed, different dynamic behaviors are observed during the current transfer phase.

Keywords

Type
Research Article
Copyright
© EDP Sciences, 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Debellut, E., Gary, F., Cajal, D., Laurent, A., J. Phys. D Appl. Phys. 34, 11 (2001) CrossRef
Toumazet, J.P., Brdys, C., Laurent, A., Ponthenier, J.L., Meas. Sci. Technol. 16, 1525 (2005) CrossRef
D. Cajal, J.P. Toumazet, F. Gary, E. Debellut, C. Brdys, C. Arnoux, L. Moreau, A. Laurent, in Proc. 22nd Int. Conf. on Electrical Contacts (ICEC), Seattle, USA, 2004, p. 347
D. Cajal, C. Brdys, J.P. Toumazet, F. Gary, A. Laurent, C. Arnoux, in Proc. 24th Int. Conf. on Electrical Contacts (ICEC), Saint-Malo, France, 2008, p. 467
G. Demoment, J. Idier, J.-F. Giovannelli, A. Mohammad-Djafari, Problèmes inverses en traitement du signal et de l'image, in Traité Télécoms, Vol. TE 5 235 (Techniques de l'Ingénieur, Paris, 2001), pp. 1–25
Charbonnier, P., Blanc-Féraud, L., Aubert, G., Barlaud, M., IEEE Trans. Image Process. 6, 2 (1997) CrossRef