Hostname: page-component-848d4c4894-jbqgn Total loading time: 0 Render date: 2024-06-30T02:43:20.286Z Has data issue: false hasContentIssue false

New laboratory techniques using heterodyne receivers

Published online by Cambridge University Press:  12 October 2020

Nadine Wehres
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Kirill Borisov
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Katharina von Schoeler
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Patrick Pütz
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Cornelia Honingh
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Frank Lewen
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Stephan Schlemmer
Affiliation:
I. Physics Institute, University of Cologne, Zülpicher Strasse 77, 50937 Köln, Germany email: wehres@ph1.uni-koeln.de
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Two laboratory emission spectrometers have been designed and described previously. Here, we present a follow-up study with special focus on absolute intensity calibration of the new SURFER-spectrometer (SUbmillimeter Receiver For Emission spectroscopy of Rotational transitions), operational between 300 and 400 GHz and coincident with ALMA (Atacama Large Millimeter/submillimeter Array) Band 7.

Furthermore, we present a feasibility study to extend the detection frequencies up to 2 THz. First results have been obtained using the SOFIA (Stratospheric Observatory for IR Astronomy) upGREAT laboratory setup which is located at the University of Cologne. Pure rotational spectra of the complex molecule vinyl cyanide have been obtained and are used to give an estimate on the sensitivity to record ro-vibrational transitions of molecules with astrophysical importance at 2 THz.

Type
Contributed Papers
Copyright
© International Astronomical Union 2020

References

Bernath, P. F. 2005 Spectra of Atoms and Molecules, Second Edition, pp. 275278 Google Scholar
Borgers, T. R. & Strauss, H. L. 1966, J. Chem. Phys., 45, 947 CrossRefGoogle Scholar
Frisch, M. J. et al. 2009, Gaussian 09, Gaussian, Inc., Wallingford CT Google Scholar
Kisiel, Z., Pszczółkowski, L., Drouin, B. J., et al. 2012, J. Mol. Spectrosc., 280, 134 CrossRefGoogle Scholar
Malloci, G., Joblin, C., & Mulas, G. 2007, Chem. Phys., 332, 353 CrossRefGoogle Scholar
Müller, H. S. P., Schlöder, F., Stutzki, J., et al. 2005, J. Mol. Struct., 742, 215 Google Scholar
Risacher, C., Gusten, R., Stutzki, J., et al. 2016, IEEE Trans. THz Sci. Technol., 6, 199 CrossRefGoogle Scholar
Tanarro, I., Alemán, B., de Vicente, P., et al. 2018, A&A, 609, A15 Google Scholar
Wehres, N., Heyne, B., Lewen, F., Hermanns, M., Schmidt, B., Endres, C., Graf, U. U., Higgins, D. R., Schlemmer, S. et al. 2018a, Astrochemistry VII: Through the Cosmos from Galaxies to Planets, Proc. IAUS 332Google Scholar
Wehres, N., Maßen, J., Borisov, K., Schmidt, B., Lewen, F., Graf, U. U., Honingh, C. E., Higgins, D. R., Schlemmer, S. et al. 2018b, PCCP, 20, 5530CrossRefGoogle Scholar
Western, C. M. 2017, J. Quant. Spec. Rad. Trans., 186, 221 CrossRefGoogle Scholar