Hostname: page-component-5c569c448b-8lphq Total loading time: 0.213 Render date: 2022-07-01T23:40:21.102Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "useRatesEcommerce": false, "useNewApi": true } hasContentIssue true

RIR - Measurement and Use in Quantitative XRD

Published online by Cambridge University Press:  10 January 2013

Camden R. Hubbard
Affiliation:
Ceramics Division, National Bureau of Standards, Gaithersburg, Maryland 20899, U.S.A.
Robert L. Snyder
Affiliation:
New York State College of Ceramics, Alfred University, Alfred, New York 14802, U.S.A.
Rights & Permissions[Opens in a new window]

Abstract

HTML view is not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The Reference Intensity Ratio (RIR) is a general, instrument-independent constant for use in quantitative phase analysis by the X-ray powder diffraction internal standard method. When the reference standard is corundum, RIR is known as I/Ic; These constants are collected in the Powder Diffraction File (1987), can be calculated, and can be measured. Recommended methods for accurate measurement of RIR constants are presented, and methods of using these constants for quantitative analysis are discussed. The numerous, complex constants in Copeland and Bragg's method introduced to account for superimposed lines can be simply expressed in terms of RIR constants and relative intensities. This formalism also permits introduction of constraints and supplemental equations based on elemental analysis.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1988

References

Alexander, L. E. and Klug, H. P. (1948). Anal. Chem. 20, 886.CrossRefGoogle Scholar
Chung, F. H. (1975). Quantitative Interpretation of X-Ray Diffraction Patterns. III. Simultaneous Determination of a Set of Reference Intensities. J. Appl. Crystallogr. 8, 17.CrossRefGoogle Scholar
Clark, G. L. & Reynolds, D. H. (1936). Ind. Eng. Chem. Anal. Ed. 8, 36.CrossRefGoogle Scholar
Cline, J. (1988). An Experimental Verification of A. W. Brindley's Microabsorption Theory. In preparation.Google Scholar
Copeland, L. E. and Bragg, R. H. (1958). Anal. Chem. 30, 196.CrossRefGoogle Scholar
Hubbard, C. R., Evans, E. H. & Smith, D. K. (1976). The Reference Intensity Ratio, I/Ic, for Computer Simulated Patterns. J. Appl. Crystallogr. 9, 169.CrossRefGoogle Scholar
Hubbard, C. R. & Smith, D. K. (1977). In Adv. X-Ray Anal., ed. McMurdie, H. F., Barrett, C. S., Newkirk, J. B. & Ruud, C. O., 20, 63. New York: Plenum.Google Scholar
Klug, H. P. & Alexander, L. E. (1974). X-Ray Diffraction Procedures. 2nd ed. (a)549553, (b)365–368. New York: J. Wiley and Sons.Google Scholar
Lennox, D. H. (1957). Anal. Chem. 29, 767.Google Scholar
Navias, A. L. (1925). J. Am. Ceram. Soc. 8, 296.CrossRefGoogle Scholar
Powder Diffraction File (1987). Swarthmore, PA: International Centre for Diffraction Data.Google Scholar
Smith, S. T., Snyder, R. L. & Brownell, W. E. (1979). The Quantitative Analysis of Devonian Shales. In Adv. X-Ray Anal., ed. McCarthy, G. J., Barrett, C. S., Leyden, D. E., Newkirk, J. B. & Ruud, C. O., 22, 181. New York: Plenum.Google Scholar
Snyder, R. L., Hubbard, C. R. & Panagiotopoulos, N. C. (1981). AUTO: A Real Time Diffractometer Control System. NBSIR 81-2229. U. S. Dept. of Commerce, Natl. Bur. Stand. Gaithersburg, MD 20899.CrossRefGoogle Scholar
Snyder, R. L., Hubbard, C. R. & Panagiotopoulos, N. C. (1982). A Second Generation Automated Powder Diffraction Control System. In Adv. X-Ray Anal., ed. Russ, J. C., Barrett, C. S., Predecki, P. K. & Leyden, D. E., 25, 245. New York: Plenum.Google Scholar
Visser, J. W. & Wolff, P. M. de (1964). Absolute Intensities. Report 641.109, Technisch Physische Dienst, Delft, Netherlands.Google Scholar
You have Access
280
Cited by

Save article to Kindle

To save this article to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

RIR - Measurement and Use in Quantitative XRD
Available formats
×

Save article to Dropbox

To save this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Dropbox account. Find out more about saving content to Dropbox.

RIR - Measurement and Use in Quantitative XRD
Available formats
×

Save article to Google Drive

To save this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Google Drive account. Find out more about saving content to Google Drive.

RIR - Measurement and Use in Quantitative XRD
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *