Hostname: page-component-7bb8b95d7b-fmk2r Total loading time: 0 Render date: 2024-09-12T08:59:02.747Z Has data issue: false hasContentIssue false

Uses of ultrasonic cleaners in paleontological laboratories

Published online by Cambridge University Press:  26 July 2017

John Pojeta Jr.
Affiliation:
U.S. Geological Survey, Reston, Virginia 22092
Marija Balanc
Affiliation:
U.S. Geological Survey, Reston, Virginia 22092
Get access

Extract

Ultrasonic cleaning is a fast and usually safe method for cleaning many hard objects that are not glued together, and it is thus useful in paleontological laboratories. It is relatively ineffective for cleaning soft materials such as rubber, cloth, and fibers. Ultrasonic cleaning machines use sound waves, or mechanical vibrations, that are above the human hearing range, and operate at frequences up to 55,000 cycles per second. The sound waves are generated by a transducer (Figure 1), which changes high frequency electrical energy to mechanical energy. This mechanical energy, or vibration, is then coupled into the liquid in the cleaning tank. The vibrations cause alternating high and low pressure waves in the liquid. This action forms millions of microscopic bubbles, which expand during low pressure waves and form small cavities. During the high pressure waves, these cavities collapse, or implode, creating a mechanical scrubbinglike action, which loosens dirt on all surfaces in contact with the cleaning solution. This action can take place up to 55,000 times a second, making it seem as though the dirt is being blasted from the surface and cavities of the object being cleaned. Ultrasonic cleaning is effective wherever capillary action will take the solution. Complete cleaning usually requires from 30 seconds to two minutes (Anonymous, 1983).

Type
Techniques for Megafossils
Copyright
Copyright © 1989 Paleontological Society 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

ANONYMOUS. 1983. Instruction Manual, Bransonic Ultrasonic Cleaner, 13 p. Branson Cleaning Equipment Co. Shelton, Connecticut.Google Scholar
Gipson, M. Jr. 1963. Ultrasonic Disaggregation of Shale. Journal of Sedimentary Petrology, 33:955958.Google Scholar
Gray, J. 1965. Extraction techniques, p. 530586. In Kummel, B., and Raup, D. (eds.), Handbook of Paleontological Techniques. W.H. Freeman and Company, San Francisco.Google Scholar
Sohn, I.G. 1959. Early Tertiary ostracodes from west Pakistan. Memoir of the Geological Survey of Pakistan. Palaeontologia Pakistanica, 3(1):91 (Actual date of publication 1970).Google Scholar
Sohn, I.G. 1960. Cleaning ostracode valves with ultrasonic vibrations. Geological Society of America, Bulletin, 71(12):1982.Google Scholar
Sohn, I.G. 1961. Techniques for preparation and study of fossil ostracodes, p. Q64–70. In Moore, R.C. (ed.), Treatise on Invertebrate Paleontology, Pt. Q, Arthropoda 3, Crustacea, Ostracoda. Geological Society of America and University of Kansas Press, Lawrence.Google Scholar
Sohn, I.G., Berdan, J.M., and Peck, R.E. 1965. Ostracods, p. 7589. In Kummel, B., and Raup, D. (eds.), Handbook of Paleontological Techniques. W.H. Freeman and Company, San Francisco Google Scholar