Hostname: page-component-848d4c4894-2xdlg Total loading time: 0 Render date: 2024-06-22T00:54:17.811Z Has data issue: false hasContentIssue false

Page Sized a-Si:H 2-Dimensional Imaging Arrays

Published online by Cambridge University Press:  01 January 1993

R.A. Street
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
R. Weisfield
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
S. Nelson
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
P. Nylen
Affiliation:
University of Stockholm, Sweden
X.D. Wu
Affiliation:
Xerox Palo Alto Research Center, Palo Alto, CA 94304
Get access

Abstract

The first page-sized a-Si:H sensor array intended for use as a contact imager is described. The array collects light very efficiently, making it well suited to high speed document input and medical x-ray imaging (by the addition of a phosphor). The array structure, control electronics and imaging properties are discussed. Data is presented from a 13" diagonal array with 512⋗560 pixels of size 0.45 mm, although the technology is capable of higher resolution. The image is read-out using 8 ICs containing 64 voltage sensitive amplifiers. The intrinsic dynamic range of the imaging array is about 105, but is limited to <1000 by the read-out amplifiers. The minimum read-out time of about 25 msec allows real time imaging.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Thompson, M.J., MRS Symp. Proc., 70, 613 (1986).Google Scholar
2. Weisfield, R. L., MRS Symp Proc., 258, 1105, 1992.Google Scholar
3. Tuan, H.C., J. Non-cryst. Solids 115,132(1989).Google Scholar
4. Yamano, M. and Takesada, H., J. Non-cryst. Solids 77&78, 1383 (1985).Google Scholar
5. Street, R. A., Nelson, S., Antonuk, L. and Perez-Mendez, V., MRS Symp. Proc. 192, 441 (1990).Google Scholar
6. Powell, M. J., French, I. D., Hughes, J. R., Bird, N. C., Davies, O. S., Glasse, C. and Curran, J. E., MRS Symp Proc., 258, 1127,(1992).Google Scholar
7. Street, R.A., MRS Bulletin, vol 18, No. 11, 70(1992).Google Scholar
8. Antonuk, L. E., Boudry, J., Huang, W., Morton, E. J., Yorkston, J., McShan, D., Longo, M. J. and Street, R. A., Medical Physics 19(6) in press.Google Scholar
9. Street, R. A., Fujieda, I., Weisfield, R. L., Nelson, S., Nylen, P., MRS Symp. Proc. 258, 1145, 1992.Google Scholar
10. Fujieda, I., Street, R. A., Weisfield, R. L., Nelson, S., Nylen, P., Perez-Mendez, V. and Cho, G., Jap. J. Appl. Phys., 32, 198 (1993).Google Scholar
11. Street, R.A., Weisfield, R. L., Nelson, S. and Chang, R., Proc. IS&T/SPIE Symposium on Electronic Imaging Science and Technology, in press.Google Scholar