Hostname: page-component-77c89778f8-cnmwb Total loading time: 0 Render date: 2024-07-19T07:29:40.010Z Has data issue: false hasContentIssue false

Optical Gas Sensor Using Cobalt Oxide Thin Film Prepared by Pulsed Laser Ablation

Published online by Cambridge University Press:  01 February 2011

Hyun-Jeong Nam
Affiliation:
hj-nam@aist.go.jp, National Institute of Advanced Industrial Science and Technology (AIST), Nanoarchitectonics Research Center (NARC), Central 5, 1-1-1 Higashi,, Tsukuba, Ibaraki, 305-8565, Japan, +81-29-861-6333, +81-29-861-6355
Takeshi Sasaki
Affiliation:
takeshi.sasaki@aist.go.jp, National Institute of Advanced Industrial Science and Technology (AIST), Nanoarchitectonics Research Center (NARC), Japan
Naoto Koshizaki
Affiliation:
koshizaki.naoto@aist.go.jp, National Institute of Advanced Industrial Science and Technology (AIST), Nanoarchitectonics Research Center (NARC), Japan
Get access

Abstract

Gas sensors based on optical absorption changes in thin films are of interest for detection of various gases such as CO, NO, H2. Optical gas sensors have several advantages over conventional electronic gas sensors, including the potential for higher sensitivity, reduced signal noise, and compatibility with combustible gases. Pulsed laser deposition (PLD) is an excellent method to prepare thin films with controllable thickness, composition and microstructures. Recently, our group reported that films of cobalt oxide prepared by PLD exhibit remarkably high sensitivity), showing an absorbance change in CO gas 70 times greater than those prepared by sputtering methods). Here we examine the effect of film microstructure and composition on CO gas sensing properties in order to identify the origin of the high sensitivity. Cobalt oxide films were prepared by PLD from a CoO target in an inert argon gas at various pressures. Films prepared near vacuum were smooth and continuous while the porosity and grain size increased linearly with pressure. In addition the pressure affected the composition and the thickness of the films. Data on the detection of CO gas suggests a direct relationship between sensitivity to CO gas and the effective surface area of films. We will discuss how the ablation plume can be used to tune the surface area for optimal sensitivity, and will demonstrate origin of the high detection sensitivity based on the structural changes with detecting gas.

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Martucci, A., Buso, D., Guglielmi, M., Zbroniec, L., Koshizaki, N., and Post, M., J. Sol-Gel Sci. Tech. 32, 243246 (2004).Google Scholar
2. Ando, M., Kobayashi, T., and Haruta, M., Catal. Today 36, 135141(1997).Google Scholar
3. Cantalini, C., Post, M., Buso, D., Guglielmi, M., and Martucci, A., Sens. Actuators B 108, 184192 (2005).Google Scholar
4. Koshizaki, N., Yasumoto, K., and Sasaki, T., Sens. Actuators B 66, 122124 (2000).Google Scholar
5. Zbroniec, L., Sasaki, T., and Koshizaki, N., Technical Digest of the 10thInternational Meeting on Chemical Sensors, Tsukuba, Japan (2004) p.358359.Google Scholar
6. Jin, Z., Zhou, H.J., Jin, Z.L., Savinell, R. F., and Liu, C.C., Sens. Actuators B 52, 188194 (1998).Google Scholar
7. Aké, C. Sánchez, Sobral, H., Muniz, M. Villagrán, Escobar-Alarcón, L., and Camps, E., Opti. Lasers Eng. 39, 581588 (2003).Google Scholar
8. Szörényi, T. and Geretovszky, Zs., Thin Solid Films 453–454, 431435 (2004).Google Scholar
9. Chrisey, D. B. and Hubler, G. K., Pulsed Laser Deposition (Wiley, New York, 1994).Google Scholar
10. Zeng, X., Koshizaki, N., Sasaki, T., Appl. Phys. A 69, S253–S255 (1999).Google Scholar
11. Syarif, D. G., Miyashita, A., Yamaki, T., Sumita, T., Choi, Y.-S., and Itoh, H., Appl. Surf. Sci. 193, 287292 (2002).Google Scholar
12. Afonso, C. N., Gonzalo, J., Serna, R., Sande, J. C. G. de, Ricolleau, C., Grigis, C., Gandais, M., Hole, D. E., and Townsend, P. D., Appl. Phys. A 69, S201–S207 (1999).Google Scholar
13. Boccuzzi, F., Chiorino, A., Tsubota, S., and Haruta, M., Sens. Actuators B 24–25, 540543 (1995).Google Scholar
14. Ando, M., Kobayashi, T., and Haruta, M., Sens. Actuators B 32, 157160 (1996).Google Scholar
15. Wang, C.B., Lin, H.K., and Tang, C.W., Catal. Lett. 94, 6974 (2004).Google Scholar
16. Oku, M., and Sato, Y., Appl. Surf. Sci. 55, 3741 (1992).Google Scholar
17. Jiménez, V. M., Fernández, A., Espinós, J. P., and González-Elipe, A. R., J. Electron Spectrosc. Relat. Phenom. 71, 6171 (1995).Google Scholar
18. Armelao, L., Barreca, D., Gross, S., and Tondello, E., J. Phys. IV France 11, Pr3437 (2001).Google Scholar
19. Varkey, A. J. and Fort, A. F., Sol. Energy Mater. Sol. Cells 31, 277282 (1993).Google Scholar
20. Monk, P. M. S., Chester, S. L., Higham, D. S., and Partridge, R. D., Electrochim. Acta 39, 22772284 (1994).Google Scholar