Hostname: page-component-848d4c4894-4rdrl Total loading time: 0 Render date: 2024-06-24T02:43:39.955Z Has data issue: false hasContentIssue false

Improved Near Surface Heavy Impurity Detection by a Novel Charged Particle Energy Filter Technique

Published online by Cambridge University Press:  21 February 2011

K. Ishibashi
Affiliation:
Dept of Physics and Astronomy, University of North Carolina, Chapel Hill, NC 27599-3255 Kobe Steel Ltd., Electronics Research Lab., Nishi-Ku, Kobe 651-22, Japan.
B.K. Patnaik
Affiliation:
Dept of Physics and Astronomy, University of North Carolina, Chapel Hill, NC 27599-3255
N. R. Parikh
Affiliation:
Dept of Physics and Astronomy, University of North Carolina, Chapel Hill, NC 27599-3255
H. Tateno
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6048
J.D. Hunn
Affiliation:
Kobe Steel Ltd., Electronics Research Lab., Nishi-Ku, Kobe 651-22, Japan.
Get access

Abstract

As the typical feature size of silicon integrated circuits, such as in VLSI technology, has become smaller, the surface cleanliness of silicon wafers has become more important. Hence, detection of trace impurities introduced during the processing steps is essential. A novel technique, consisting of a “Charged Particle Energy Filter (CPEF)” used in the path of the scattered helium ions in the conventional Rutherford Backscattering geometry, is proposed and its merits and limitations are discussed. In this technique, an electric field is applied across a pair of plates placed before the detector so that backscattered particles of only a selected energy range go through slits to strike the detector. This can be used to filter out particles from the lighter substrate atoms and thus reduce pulse pileup in the region of the impurity signal. The feasibility of this scheme was studied with silicon wafers implanted with 1×1014 and 1×1013 14pe/cm2 at energy of 35 keV, and a 0.5 MeV He+ analysis beam. It was found that the backscattered ion signals from the Si atoms can be reduced by more than three orders of magnitude. This suggests the detection limit for contaminants can be improved by at least two orders of magnitude compared to the conventional Rutherford Backscattering technique. This technique can be incorporated in 200–300 kV ion implanters for monitoring of surface contaminants in samples prior to implantation.

Type
Research Article
Copyright
Copyright © Materials Research Society 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Brundle, C.R., Evans, C. A. Jr., and Wilson, S. (Editors), ‘Encyclopedia of Materials Characterization’ (Butterworth-Heinemann)Google Scholar
2 Gunzler, R., Schule, V., Seeliger, G., Weiser, M., Bohringer, K., Kalbitzer, S. and Kemmer, J., Nucl. Instr. and Meth. B35, 522529 (1988)Google Scholar
3 Knapp, J.A. and Banks, J.C., MRS proceeding of symposium A, Fall 1994 Google Scholar
4 Ross, G.G. and Leblane, L., Nucl. Instr. and Meth. B62, 484492 (1992)Google Scholar