Hostname: page-component-848d4c4894-tn8tq Total loading time: 0 Render date: 2024-06-28T01:08:47.862Z Has data issue: false hasContentIssue false

Electronic Detection and Quantification of ions in solution using an a-Si:H Field-effect Device

Published online by Cambridge University Press:  31 January 2011

João Costa
Affiliation:
jcosta@deetc.isel.ipl.pt, ISEL, DEETC, Lisbon, Portugal
Miguel Fernandes
Affiliation:
mfernandes@deetc.isel.ipl.pt, ISEL, Rua Conselheiro Emídio Navarro, 1, Lisbon, 1959-007, Portugal
Manuela Vieira
Affiliation:
mv@isel.pt, ISEL, DEETC, Lisbon, Portugal
G. Lavareda
Affiliation:
gal@fct.unl.pt, CTS, Lisbon, Portugal
C. N. Carvalho
Affiliation:
canc@ist.utl.pt, ICEMS, Lisbon, Portugal
Amin Karmali
Affiliation:
akarmali@deq.isel.ipl.pt, ISEL, Chemical Engineering and Biotechnology Research Center, Lisbon, Portugal
Get access

Abstract

Progress in microelectronics and semiconductor technology has enable new capabilities in the field of sensor construction, particularly of pH sensors based on field-effect transistors (FETs) as transducers of chemical signal. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use in the food industry. Interest in biosensors consisting of a semiconductor transducer and a functionalized surface with biomolecule receptors (BioFET) continues to grow as they hold the promise for highly selective, label-free, real-time sensing as an alternative to conventional optical detection techniques. We have been involved in the development of a biosensor where the enzymatic activity of recombinant amidase from Escherichia coli is coupled to a semiconductor transducer for the detection of toxic amides in food and industrial effluents. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the sensor displays the desired current-voltage characteristics. In addition we present an electrical model of the device, in agreement with the experimental data, that is sensitive to the pH of the solution.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] D'Amico, A. and Fortunato, G., Ambient sensors, in Semiconductors and Semimetals, vol. 21, Pankove, J. I., Ed. New York: Academic, 1984, pp. 209237.Google Scholar
[2] Gotoh, M. Oda, S. Shimizu, I. Seki, A. Tamiya, E. and Karube, I. Sensors and Actuators, 16, 1/2, pp. 5565, (1989). Google Scholar
[3] Liao, Hung-Kwei, Chou, Jung-Chuan, Chung, Wen-Yaw, Sun, Tai-Ping and Hsiung, Shen-Kan, Sensors and Actuators B, 50, 104109, (1998).Google Scholar
[4]Fjeldly, T. A. Ytterdal, T. and Shur, M. Introduction to Device Modeling and Circuit Simulation, John Wiley & Sons, New York, 1998.Google Scholar
[5] Martinoia, S. Massobrio, G. Lorenzelli, L. Sensors and Actuators B, 105, 1427, (2005).Google Scholar
[6] Yates, D.E. Levine, S. Healy, T.W. J. Chem. Soc. Farady Trans. 70, 18071818, (1974).Google Scholar
[7] Martinoia, S. Massobrio, G. Sensors and Actuators B, 62, 182189, (2000).Google Scholar
[8] Bousse, L. Rooij, N.F. de, Bergveld, P. Operation, IEEE Trans. Electron Devices ED, 30, 10, 12631270, (1983).Google Scholar
[9] Shur, M. and Hack, M. J. Appl. Phys. 55, 10, 3831, (1984).Google Scholar