Hostname: page-component-76fb5796d-qxdb6 Total loading time: 0 Render date: 2024-04-26T08:38:37.773Z Has data issue: false hasContentIssue false

Concentration Measurements of Chlorine Atoms in A Plasma Reactor

Published online by Cambridge University Press:  28 February 2011

Joda Wormhoudt
Affiliation:
Aerodyne Research, Inc., 45 Manning Road, Billerica, MA 01821
Alan C. Stanton
Affiliation:
Aerodyne Research, Inc., 45 Manning Road, Billerica, MA 01821
Albert D. Richards
Affiliation:
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Herbert H. Sawin
Affiliation:
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Get access

Abstract

Infrared absorption spectroscopy has been used to measure atomic chlorine concentrations over a range of plasma conditions in both Cl2 and CF3Cl discharges.These measurements were made utilizing the spin-orbit transitions in the ground state of atomic chlorine near 882 cm−1.The concentration studies were performed by passing light from a diode laser through a multi-pass (White) cell set in two opposed windows of a parallel plate plasma etching reactor.The plasma work was preceded by a laboratory measurement of the infrared absorption line strengths of the 2P1/22P3/2 transition.This measurement was done in a known concentration of atomic chlorine produced in a low pressure discharge flow system by the reaction of Cl2 or HCl with excess fluorine atoms.These measurements resulted in an integrated line strength of 4.14 (±0.89) × 10−21 cm2-molecule−1-cm−1 for the strongest hyperfine component of the transition at 882.3626 cm−1.

Measured atomic chlorine concentrations in Cl2 discharges varied between 0.2 and 8.0 × 1014 atoms/cm3, representing atomic chlorine fractions on the order of a few percent.The measured atomic chlorine concentrations increased approximately linearly with increasing power and pressure, and increased with increasing frequency above approximately 1 MHz.Below 1 MHz, the atomic chlorine concentration was relatively independent of frequency.

Type
Articles
Copyright
Copyright © Materials Research Society 1986

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Stanton, A.C., Chem.Phys.Lett. 122, 385 (1985).Google Scholar
2. Maki, A., Wells, J.S., Peterson, F.R., Olsen, W.B., Fayt, A., and Sattler, J.P., J.Chem.Phys.Ref.Data (to be published).Google Scholar
3. Stanton, A.C., Wormhoudt, J.C., and Duff, J.W., in Spectral Line Shapes, edited by Burnett, K. (Walter deGryter, New York, 1983) Vol.2, p.515.Google Scholar
4. Dagenad, M., Johns, J.W.C., and McKellar, A.R.W., Can.J.Phys. 54, 1438 (1976).Google Scholar
5. Phillips, D.M., J.Phys.D 8, 507 (1975).Google Scholar
6. Porter, R.A. and Harshbarge, W.R., J.Electrochem.Soc. 126 (3), 460 (1979).CrossRefGoogle Scholar
7. Harshbarger, W.R., Solid State Technol. 4, 126 (1982).Google Scholar
8. Oshima, M., Jpn.J.Appl.Phys. 17 (6), 1157 (1978).Google Scholar
9. Davis, G.P. and Gottscho, R.A., J.Appl.Phys. 54 (6), 3080 (1983).Google Scholar