Hostname: page-component-77c89778f8-m42fx Total loading time: 0 Render date: 2024-07-18T16:28:11.147Z Has data issue: false hasContentIssue false

Technique of surface control with the Electrolyzed D.I.water for post CMP cleaning

Published online by Cambridge University Press:  17 March 2011

Mitsuhiko Shirakashi
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Kenya Itoh
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Ichiro Katakabe
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Masayuki Kamezawa
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Sachiko Kihara
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Manabu Tsujimura
Affiliation:
Precision Machinery Group, Ebara Corporation 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Takayuki Saitoh
Affiliation:
Center of Technology Development, Ebara Research CO., Ltd. 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Kaoru Yamada
Affiliation:
Center of Technology Development, Ebara Research CO., Ltd. 4-2-1, Honfujisawa, Fujisawa-shi 251-8502, Kanagawa, Japan
Naoto Miyashita
Affiliation:
Manufacturing Engineering Center, Toshiba Corporation Semiconductor Company 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8522, Kanagawa, Japan
Masako Kodera
Affiliation:
Manufacturing Engineering Center, Toshiba Corporation Semiconductor Company 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8522, Kanagawa, Japan
Yoshitaka Matsui
Affiliation:
Manufacturing Engineering Center, Toshiba Corporation Semiconductor Company 8, Shinsugita-cho, Isogo-ku, Yokohama 235-8522, Kanagawa, Japan
Get access

Abstract

Chemical mechanical planarization (CMP) has been widely used for planarization of ILD, STI, plug and wiring processes. In post metal CMP cleaning processes, there are still many problems to be solved. There are several surfaces of materials, such as wiring materials, barrier materials, dielectric materials etc., on the wafer that must be cleaned at the same time,. It is also important to clean these different surfaces without any chemical or mechanical damage. We have confirmed that the Electrolyzed D.I.water is effective in post CMP cleaning for controlling the surface condition during cleaning and leaving a robust surface after CMP. We describe the Electrolyzed D.I.water system and present some results on the cleaning capability and control of the metal surface for application to cleaning after a metal CMP process.

Type
Research Article
Copyright
Copyright © Materials Research Society 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Miyashita, N., Mase, Y., Takayasu, J., Minami, Y., Kodera, M., Abe, M., Izumi, T.: “Mechanism of a New Post CMP Cleaning for Trench Isolation Process”, Materials Research Society 1999 Spring Meeting, San Francisco, CA, April 1999.10.1557/PROC-566-253Google Scholar
[2] Briggs, D., Seah, M.P.: “Practical Surface Analysis by Auger and X-ray Photoelectron Spectroscopy”, John Wiley & Sons Ltd. Google Scholar
[3] The surface science society of Japan: “Method of X-ray Photoelectron Spectroscopy”, MaruzenGoogle Scholar