Hostname: page-component-564cf476b6-2fphr Total loading time: 0.259 Render date: 2021-06-20T08:07:04.351Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true }

Interfaces of Molecular Recognition Sites and Biosensors; Novel Bio-Sensing Materials

Published online by Cambridge University Press:  09 June 2015

Kyung M. Choi
Affiliation:
University of California at Irvine, Irvine CA 92697, U. S. A.
Get access

Abstract

We introduce a sensing element, “Molecularly Imprinted Polymer (MIP),” which created by “Molecular Imprinted Technique.” However, the sensitivity of MIP’s based bio-sensors limits for practical applications due to the low sensitivity. To achieve a high sensitivity of MIP’s based sensors, the synthesis of “high affinity receptor or binding sites,” such as “monoclonal particles” is a key objective. In previous studies, affinity distribution plots indicated that “high affinity binding sites” were obtained when the number of binding sites per particle decreased. It means that smaller particles are expected to have higher affinity binding sites compared to larger particles. The result motivated us to produce small-sized MIP’s particles for the achievement of higher sensitivity. Microfluidic Synthesis has taken a great attention to synthesize small particles. However, the microfluidic synthesis gave us a difficulty, especially collections of MIP’s particles from the surface of PDMS-based microchannels due to a sticking problem. Thus, we employed a new approach, which can collect MIP’s particles without any sticking problem from the surface of the reactor. It is a photopatterned MIP’s system generated on the glass surface. We prepared a photomask with micro-sized patterns and then fabricate MIP’s particles on a glass surface by photopolymerization. Uniform MIP’s patterns were printed on the glass surface. The interface between the glass surface and the MIP’s pattern was observed by SEM. Micro-sized MIP’s particles were collected from the glass surface by scratching off the photocured MIP’s patterns.

Type
Articles
Copyright
Copyright © Materials Research Society 2015 

Access options

Get access to the full version of this content by using one of the access options below.

References

Conrad, P. G., Nishimura, P. T., Aherne, D., Schwartz, B. J., Wu, D., Fang, N., Zhang, X., Roberts, J. M., and Shea, K. J., Adv. Mater. 15, 1541 (2003).CrossRef
Choi, K. M. and Rogers, J. A., J. Am. Chem. Soc. 125, 4060 (2003).CrossRef
Choi, K. M., Phys, J.. Chem. B. 109, 21525 (2005).CrossRef
Choi, K. M., Research Letters in Materials Science 2008, 458158 (2008).CrossRef
Shea, K. J., Lee, A. P., and Mingdi, Y., PMSE Preprints 90, 160 (2004).
Jensen, K. and Lee, A. P., Lab. Chip. 4, 31N (2004).CrossRef
Reyes, D. R., Lossifidis, D., Auroux, P.A., and Manz, A., Anal. Chem. 74, 2623 (2002).CrossRef
Tan, Y. C., Fisher, J. S., Lee., A. I. V., Cristini, V, and Lee, A. P., Lab. Chip. 4, 292 (2004).CrossRef
Zheng, B., Tice, J. D., and Ismagilov, R. F., Anal. Chem. 76, 4977 (2004).CrossRef
Edel, J. B., Fortt, R., DeMello, J. C., and DeMello, A. J., Chem. Commun. 10, 1136 (2002).CrossRef
Shestopalov, I., Tice, J. D., and Ismagilov, R. F., Lab. Chip. 4, 316 (2004).CrossRef
Hung, L.-H., Tseng, W.-Y., Choi, K. M., Tan, Y.-C., Shea, K. J., and Lee, A. P., Proc. MicroTAS 2004 2, 539 (2004).
Okushima, S., Nisisako, T., Torii, T., and Higuchi, T., Proc. MicroTAS 2004 1, 258 (2004).

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Interfaces of Molecular Recognition Sites and Biosensors; Novel Bio-Sensing Materials
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Interfaces of Molecular Recognition Sites and Biosensors; Novel Bio-Sensing Materials
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Interfaces of Molecular Recognition Sites and Biosensors; Novel Bio-Sensing Materials
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *