Hostname: page-component-76fb5796d-45l2p Total loading time: 0 Render date: 2024-04-26T21:44:29.748Z Has data issue: false hasContentIssue false

Analytical and numerical analysis of a solar thermoelectric system cooled by an active system

Published online by Cambridge University Press:  14 January 2018

Francisco Montero*
Affiliation:
Micro and Nano fluids laboratory and Laboratory of solar and thermal energy conversion technologies, Department of Mechanical Engineering, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna4860, Macul, Santiago, Chile.
Mario Di Capua
Affiliation:
Micro and Nano fluids laboratory and Laboratory of solar and thermal energy conversion technologies, Department of Mechanical Engineering, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna4860, Macul, Santiago, Chile.
Amador Guzmán
Affiliation:
Micro and Nano fluids laboratory and Laboratory of solar and thermal energy conversion technologies, Department of Mechanical Engineering, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna4860, Macul, Santiago, Chile.
*
*(Email: fjmontero@uc.cl)
Get access

Abstract

A solar thermoelectric generator (STEG) system composed of an optical concentrator system (OPS), a Bismuth Telluride thermoelectric module (TEG), and a cold plate-based cooling system (CPCS) was numerically simulated, to measure the efficiency of electric generation of a commercial thermoelectric module under controlled temperatures. The OPS is composed by a Fresnel lens that allows a temperature of around 200 °C, the OPS works with a solar irradiance of 1000 W/m2 (AM 1.5 Reference) and an optical concentration of 60. The OPS is coupled to the hot side of the TEG that consists of a commercially available thermoelectric module. The CPCS maintains a temperature of around 50 °C on the cold side of the TEG. To evaluate the configuration, a computational fluid dynamic (CFD) analysis was carried out to evaluated the thermal performance of the CPCS and the temperature achieved on the upper surface of the cooling device. Based on the numerical results generated by the CFD analysis, an analytical TEG efficiency of around 5% was achieved when a temperature difference, between the hot and cold sides of the commercial TE module, of 150 °C was maintained. We perform an analysis using the Hogan and Shih model that uses the thermoelectric material properties exposed by Chen et al.

Type
Articles
Copyright
Copyright © Materials Research Society 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Goldsmid, H. J., Br. J. Appl. Phys. 11, 209 (1960).Google Scholar
Amatya, R. and Ram, R. J., J. Electron. Mater. 39, 1735 (2010).Google Scholar
Kraemer, D., McEnaney, K., Chiesa, M., and Chen, G., Sol. Energy. 86, 1338 (2012).Google Scholar
Rowe, D. M., Thermoelectrics handbook: Macro to Nano, 1st ed. (Taylor & Francis, Boca Raton, 2005) p. 1014.Google Scholar
McEnaney, K., Kraemer, D., Ren, Z., and Chen, G., J. Appl. Phys. 110, 7 (2011).Google Scholar
Chen, W. H., Wang, C. C., Hung, C. I., Yang, C. C., and Juang, R. C., Energy. 64, 287 (2014).CrossRefGoogle Scholar
Sundarraj, Pradeepkumar. RSCAdvances. 4, 46860 (2014).Google Scholar
Kraemer, Daniel, Energy. 153 (2016).Google Scholar
Chen, G., Journal of Applied Physics. 109, 104908 (2011).Google Scholar
Incropera, F., Liquid Cooling of Electronic Devices by Single-Phase Convection, (Wiley, London, 1999) p. 205.Google Scholar