Hostname: page-component-848d4c4894-pjpqr Total loading time: 0 Render date: 2024-06-26T12:39:16.098Z Has data issue: false hasContentIssue false

Advances in High Resolution Cryo-EM Studies: the Quartenary Structure of the 70S E.Coli Ribosome Revealed at 11.5Å Resolution.

Published online by Cambridge University Press:  02 July 2020

P. Penczek
Affiliation:
Wadsworth Center, Empire State Plaza, Albany, NY, 12201-0509.
Ch.M.T. Spahn
Affiliation:
Wadsworth Center, Empire State Plaza, Albany, NY, 12201-0509. Department of Biomedical Sciences, State University of New York at Albany, NY, 12201-0509.
R.K. Agrawal
Affiliation:
Howard Hughes Medical Institute at Health Research Inc., Wadsworth Center, State University of New York at Albany, NY, 12201-0509.
I.S. Gabashvili
Affiliation:
Department of Biomedical Sciences, State University of New York at Albany, NY, 12201-0509.
R.A. Grassucci
Affiliation:
Department of Biomedical Sciences, State University of New York at Albany, NY, 12201-0509.
J. Frank
Affiliation:
Wadsworth Center, Empire State Plaza, Albany, NY, 12201-0509.
Get access

Extract

Three-dimensional cryo-electron microscopy (EM) of macromolecular assemblies with low or nonexistent symmetry in single-particle form is now recognized as a powerful, legitimate method of structure research. The progress in the resolution achieved has always been related to the introduction of new image processing methods and to improvements in understanding of the overall strategy of single particle analysis. The new techniques either were adopted from methods developed in other fields, or were specifically designed to deal with extremely low Signal-to-Noise Ratio (SNR) data in EM. In the former category we can place multivariate statistical analysis, clustering techniques, correlation techniques, and tomographic methods, in the latter alignment methods, three-dimensional (3D) projection alignment, contrast transfer function (CTF) correction methods, and common-lines based orientational search. In addition, there have been steady improvements of the quality of the data by seeking better electron microscopy conditions (usage of higher microscope voltage and of microscopes equipped with a field emission gun).

Type
Electron Cryomicroscopy of Macromolecules
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Gabashvili, I.S. et al. Solution structure of the E.coli 70S ribosome at 11,5Å resolution. Cell, in press.Google Scholar