Hostname: page-component-848d4c4894-75dct Total loading time: 0 Render date: 2024-04-30T23:56:43.911Z Has data issue: false hasContentIssue false

PIV and MFC measurements in a continuous caster mould. New tools to penetrate the caster black box

Published online by Cambridge University Press:  25 October 2002

Get access

Abstract

When argon gas is injected into the caster moulds, the similarity between water models and actual casting conditions comes into question. This is why LTV decided to investigate new technologies. The paper presents these technologies and discusses the programme results. PIV is a powerful laser-based technology that was used on the LTV 0.4 and full-scale water models to determine water velocities. MFC sensors are magnetic sensors that were installed on the LTV Cleveland-East 2-strand slab caster to measure actual liquid steel velocities. In addition, nails boards, X-ray and SEM analyses were extensively used to determine molten slag layer thickness profiles during casting, gas bubbles/pinholes location and steel defect composition, respectively.

Type
Research Article
Copyright
© La Revue de Métallurgie, 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)