Hostname: page-component-848d4c4894-xfwgj Total loading time: 0 Render date: 2024-07-01T08:06:32.955Z Has data issue: false hasContentIssue false

Exclusion of Noninfectious Medical Waste From the Contaminated Waste Stream

Published online by Cambridge University Press:  02 January 2015

Abstract

The purpose of this study was to determine whether any waste was labeled incorrectly as infectious or contained material that could be recycled. Waste generated in preparation for surgery was separated and weighed. Of 530 lbs of operating room waste, 40 lbs were noninfectious, largely plastic and paper. The results of the present study suggest a segment of waste can be removed from the contaminated stream, potentially reducing hospital costs and improving our environment.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Rutala, WA, Weber, DJ. Infectious waste—mismatch between science and policy. N Engl J Med 1991;325:578581.CrossRefGoogle ScholarPubMed
2. Rutala, WA, Odette, RL, Samsa, GP. Management of infectious waste by United States hospitals. JAMA 1989;262:16351640.CrossRefGoogle Scholar
3. Harrell, GP, Catanzariti, C. Federal and state regulation of medical waste. J Leg Med 1994;15:188.CrossRefGoogle ScholarPubMed
4. Hyland, RG. Regulatory developments affecting medical waste disposal. 86th Annual Meeting and Exhibition, Air and Waste Management Association; 06 13-18,1993; Denver, CO. Paper no. 93-T-A-47.03.Google Scholar
5. US EPA, Office of Solid Wastes. Medical Waste Management in the United States: First Interim Report to Congress. Washington, DC; 05 1990. EPA/530-SW-90-051a.Google Scholar
6. Keene, JH. Medical waste: a minimal hazard. Infect Control Hospital Epidemiol 1991;12:682685.CrossRefGoogle ScholarPubMed
7. Bartholomew, P, Cycyota, M, Petrilli, L, Rosauer, D, Scharf, M, Giovaretto, S. Recycling post-consumer hospital wastes. 87th Annual Meeting and Exhibition, Air and Waste Management Association; 06 19-24, 1994; Cincinnati, OH. Abstract 94FA- 154.02.Google Scholar
8. DiGiacomo, JC, Odom, JW, Ritota, PC, Swan, KG. Cost containment in the operating room: use of reusable versus disposable clothing. Am Surg 1992;58:654656.Google ScholarPubMed
9. Bruning, LM. Disposables vs reusables in operating room practice, part II: weighing costs, risks and wastes. Nursing Management 1992;23:72I-72K, 72N, 72P.CrossRefGoogle Scholar
10. Carson, EK. The hazards of medical waste. Imprint 1994;41:8183.Google ScholarPubMed