Hostname: page-component-8448b6f56d-gtxcr Total loading time: 0 Render date: 2024-04-24T05:01:23.508Z Has data issue: false hasContentIssue false

Kyushu University Beamline, BL06, at SAGA Light Source

Published online by Cambridge University Press:  18 January 2011

S. Yoshioka*
Affiliation:
Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
T. Ishioka
Affiliation:
Department of Molecular and Material Science, Kyushu University, 6-1 Kasuga Koen, Kasuga, Fukuoka, 816-8580, Japan
H. Okabe
Affiliation:
Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
A. Harata
Affiliation:
Department of Molecular and Material Science, Kyushu University, 6-1 Kasuga Koen, Kasuga, Fukuoka, 816-8580, Japan
Y. Sejima
Affiliation:
Center for Research and Advancement in Higher Education, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
K. Hara
Affiliation:
Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan
T. Okajima
Affiliation:
SAGA Light Source, 8-7 Yayoigaoka, Tosu, Saga, 841-0005, Japan
*
Email address for correspondence:syoshioka@nucl.kyushu-u.ac.jp
Get access

Abstract

Kyushu University has installed the hard X-ray beamline, BL06, at bending magnet source of SAGA Light Source in Japan. It is designed for X-ray absorption fine structure (XAFS) spectroscopy and small-angle X-ray scattering (SAXS) experiments. The X-ray energy covered by the beamline ranges from 2.1 to 23 keV using a Si(111) flat double-crystal monochromator. Two bent cylindrical-type focusing mirrors are used, each with a different focal point. They are set in the optics section and can be used independently. One of the mirrors has a focal distance of 6 m, which corresponds to the sample stage for XAFS experiments, while the second mirror focuses at 10 m, corresponding to the detector for the SAXS experiments. The photon flux measured by the ion chamber at mirror focal point is 1010 phs/s. The experimental hutch houses the detection equipment for both XAFS and SAXS. For XAFS studies, a set of ion chambers for transmission mode and a Lytle detector and a Si drift detector for fluorescence yield mode are available. For SAXS studies, the camera pass length can be chosen from 0.5 to 2.5 m with 0.5 m increments in between, and an image plate is operated as signal detector. The beamline will be opened for user operation around summer 2010.

Type
Poster paper
Copyright
Copyright © Diamond Light Source Ltd 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCE

Tomimasu, T., Koda, S., Iwasaki, Y., Takabayashi, Y., Yoshida, K. & Ohogaki, H. 2007 Current status of the SAGA light source commissioning. Synchrotron Radiat. Instrum. 1 and 2, 879 (222), 184187.Google Scholar