Hostname: page-component-77c89778f8-9q27g Total loading time: 0 Render date: 2024-07-21T04:22:44.795Z Has data issue: false hasContentIssue false

Never fail to surveil! Transcatheter closure of recurrent atrial septal defect secondary to patch degradation in a young boy

Published online by Cambridge University Press:  30 June 2022

Sriram Veeraraghavan*
Affiliation:
Department of Cardiology, SRM Medical College Hospital and Research Centre, SRM Nagar, Potheri, Chengalpattu 603203, TN, India
Bharath Raj Kidambi
Affiliation:
Department of Cardiology, SRM Medical College Hospital and Research Centre, SRM Nagar, Potheri, Chengalpattu 603203, TN, India
Narendhiran Pandurangan
Affiliation:
Department of Cardiology, SRM Medical College Hospital and Research Centre, SRM Nagar, Potheri, Chengalpattu 603203, TN, India
*
Author for correspondence: Dr. Sriram Veeraraghavan, MD DM, Associate Professor, Department of Cardiology, SRM Medical College Hospital and Research Centre, SRM Nagar, Potheri, Chengalpattu 603203, TN, India. Tel: +91- 8105970705; Fax: 044-27455106. E-mails: srivats.007.2003@gmail.com, sriramv@srmist.edu.in, srm_mchrc@univ.ac.in

Abstract

We report a case of a 16-year-old boy with symptomatic recurrent atrial septal defect due to patch degradation of an autologous pericardial patch, done 10 years back. He successfully underwent transcatheter closure of the recurrent defect after meticulous assessment of patch rims for stability.

Type
Brief Report
Copyright
© The Author(s), 2022. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Geva, T, Martins, JD, Wald, RM. Atrial septal defects. Lancet 2014; 383: 19211932.CrossRefGoogle ScholarPubMed
Meijboom, F, Hess, J, Szatmari, A, et al. Long-term follow-up (9 to 20 years) after surgical closure of atrial septal defect at a young age. Am J Cardiol 1993; 72: 14311434.CrossRefGoogle ScholarPubMed
Valdes-Cruz, LM, Pieroni, DR, Jones, M, et al. Recurrent shunting in the early postoperative period after closure of atrial septal defect: echocardiographic comparison of patch materials. J Thorac Cardiovasc Surg 1982; 84: 7376.CrossRefGoogle Scholar
Okwulehie, V, Dharmapuram, AK, Swain, SK, Ramdoss, N, Sundararaghavan, S, Kona, SM. Experience with autologous pericardial patch closure of ventricular septal defect. Indian J Thorac Cardiovasc Surg 2006 Oct; 22: 212214.CrossRefGoogle Scholar
Liava'a, M, Kalfa, D. Surgical closure of atrial septal defects. J Thorac Dis 2018; 10, Suppl 24: S2931S2939. DOI 10.21037/jtd.2018.07.116.CrossRefGoogle ScholarPubMed
Atik, FA, Afiune, JY, Caneo, LF. Autologous pericardium patch aneurysm after ventricular septal defect closure and arterial switch operation: case reports. J Cardiac Surg 2009 Jul; 24: 479480.CrossRefGoogle Scholar
Mohanty, S, Kumar, DP. Percutaneous closure of atrial septal defect after surgical patch degradation. J Indian Coll Cardiol 2019; 9: 45.CrossRefGoogle Scholar
Deng, X, Yao, T, Wang, Y, et al. Transcatheter closure of a recurrent shunt with posteroinferior deficient rim after surgical closure of an ASD: a case report. BMC Cardiovasc Disord 2020 Jul 22; 20.CrossRefGoogle Scholar
Demir, B, Tureli, HO, Kutlu, G, Karakaya, O. Percutaneous closure of a postoperative recurrent atrial septal defect with the Occlutech Figulla Occluder device. Arch Turk Soc Cardiol 2012; 40: 5558.CrossRefGoogle Scholar
Chessa, M, Butera, G, Giamberti, A, Bini, RM, Carminati, M. Transcatheter closure of recurrent atrial septal defects after surgical closure. J Interv Cardiol. 2002; 15: 187189.CrossRefGoogle Scholar