SG-APSIC1149: Continuous quality improvement project: Changing from sterile to clean perineal care sets at Maharaj Nakorn Chiang Mai Hospital

Published online by Cambridge University Press:  16 March 2023

Prapaipan Wongkreua
Affiliation:
Maharaj Nakorn Chiang Mai Hospital, Chiang Mai, Thailand
Narumon Lerskornsan
Affiliation:
Maharaj Nakorn Chiang Mai Hospital, Chiang Mai, Thailand

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Objectives: The central sterile supply department (CSSD) provides sterile perineal care sets (SPC sets) for use with patients. However, the SPC sets exceed the standard, and the sterilization process incurs high cost. Therefore, a CSSD nursing team set out to find ways to save costs by providing clean perineal care sets (CPC sets) instead of sterile sets. We examined the rate of catheter-associated urinary tract infection (CAUTI) after using CPC sets, measured the satisfaction of the nursing staff who use the CPC sets, evaluated the decrease in the cost to the hospital. Methods: The CSSD nursing team presented some evidence of the benefits of using the CPC sets to the infection control subcommittee and asked for their approval to use CPC sets instead of SPC sets. After approval by the subcommittee, the CSSD nursing staff began to use CPC sets for patients. The incidence of CAUTI was monitored, and a satisfaction survey of the nurses who used the CPC sets was performed. We compared the costs between the SPC set and the CPC set to determine the cost savings. Results: The CAUTI rate did not change after using CPC sets. The nurses who used the CPC sets indicated no difference in satisfaction between the SPC and CPC sets, and the cost of the CPC set was cheaper than the SPC set (27 Baht per set). Conclusions: In a quality improvement effort, using the CPC set was safe for patients. The users were satisfied with the CPC set and trusted the safety of the instruments. Moreover, using the less expensive CPC sets saved the hospital >700,000 Baht per year.

Type
Sterilization and Disinfection
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America