Abstract

Additive elements are now included in manufacturing specifications for greases. Texaco uses X-ray fluorescence at lubricants manufacturing locations; however, analyses of greases in the neat form are difficult due to problems with uniform and repeatable filling of sample cups and outgassing of greases during measurements. This preparation procedure allows quantitative determinations of additive elements in a variety of greases using a single analytical program. Having a single method for all greases is important at busy manufacturing locations.

The preparation method involves dilution of samples in a binder powder. This approach eliminates outgassing and overcomes differences among greases such as type of soap, presence of MoS2 and graphite, and varying oil content. The powder absorbs oil and creates a uniform particle structure. Thorough mixing and careful cup packing yield repeatable measurements. The method allows the use of liquid oil standards for calibration, eliminating the need to obtain analyzed greases. Accurate calibrations have been created for both wavelength-dispersive and energy-dispersive spectrometers.

Type
IV. On-Line, Industrial and Other Applications of XRS
Copyright
Copyright © International Centre for Diffraction Data 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Hirate, H., Ameniya, T., Date, K., Bunseki Kagaku, 16(2), 99, 1967.Google Scholar
2. Fujita, M., Yamauchi, T., Kobayashi, S., Sekiyu Gakkai Shi, 11(3), 180, 1968.Google Scholar
3. Fujita, M., Yamauchi, T., Kobayashi, S., Sekiyu Gakkai Shi, 12(3), 192, 1969.Google Scholar
4. Fujita, M., Yamauchi, T., Junkatsu, 17(3), 175, 1972.Google Scholar
5. Psenick, O., Nafta (Zagreb), 39(2), 97, 1988.Google Scholar
6. Jain, M. C., Appa Rao, H. V. R., Res. Ind., 28(2), 133, 1983.Google Scholar
7. Kashiki, M. U. S. Patent No. 3705770, 1972.Google Scholar
8. Suzuki, Y., Junkatsu, 14(9), 479, 1969.Google Scholar
9. Sesulka, V., Kolihova, D., Lang, I., Ropa Uhlie, 18(8), 417, 1976.Google Scholar
10. Sychra, V., Lang, I., Sebor, G., Progress in Analytical Atomic Spectroscopy, 4(4), 341, 1981.Google Scholar
11. Kaegler, S. H., Compend. - Dtsch. Ges. Mineraloelwiss. Kohlechem., 75-76, 503, 1975.Google Scholar
12.Chemplex® X-Ray Spectrochemical Sample Preparation Equipment and Accessories Catalog, 1990.Google Scholar
13.The Shepherd Chemical Company, 4900 Beech Street, Cincinnati, OH 45212.Google Scholar
14. deJongh, W. K., X-ray Spectrometry, 2, 151, 1973.Google Scholar