Hostname: page-component-848d4c4894-xfwgj Total loading time: 0 Render date: 2024-07-07T10:08:26.141Z Has data issue: false hasContentIssue false

The Measurement of Triaxial Residual Stress in Polymer-Coated Aluminum Circuitry in Microchip Modules

Published online by Cambridge University Press:  06 March 2019

Cyrus E. Crowder
Affiliation:
Analytical Sciences, 1897G Bldg; Central Research Materials Science and Testing, 1702 Bldg; Central Research Electronics, 1712 Bldg The Dow Chemical Company, Midland, MI 48667
Michael J. Radler
Affiliation:
Analytical Sciences, 1897G Bldg; Central Research Materials Science and Testing, 1702 Bldg; Central Research Electronics, 1712 Bldg The Dow Chemical Company, Midland, MI 48667
Paul Townsend
Affiliation:
Analytical Sciences, 1897G Bldg; Central Research Materials Science and Testing, 1702 Bldg; Central Research Electronics, 1712 Bldg The Dow Chemical Company, Midland, MI 48667
Get access

Extract

The development of high density interconnection (HDI) technology in multichip modules (MCM's) will establish a new level in the hierarchy of electronic systems. The modules use organic insulating layers which, because of their low dielectric permittivity and loss, enable circuits with maximum density and speed. However, differences in the coefficients of thermal expansion (CTE's) for the insulating layers, the interconnects, and the substrates, produce residual stresses in the various components during processing. These stresses must be understood to engineer reliable designs for MCM's.

Type
V. X-Ray Characterization of Thin Films
Copyright
Copyright © International Centre for Diffraction Data 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Noyan, I. C. and Cohen, J. B., in: “Residual Stress-Measurement by Diffraction and Interpretation”, Springer-Verlag, New York, 1987, Chapter 5.Google Scholar
2. Smith, D, K. and Smith, K. L., “POWD12 - A FORTRAN-77 Program for Calculating X-ray Powder Diffraction Patterns” -1986, The Pennsylvania State University, 239 Deike Building, University Park, PA.Google Scholar
3.Siemens Analytical X-ray Instruments, Inc., 6300 Enterprise Lane, Madison, WI, U.S.A., TEX-11/ODF-11 Software, June 1988.Google Scholar
4. Hauk, V. M., Oudelhoven, R. W. M., and Vaessen, G. H. J., Met, Trans. A, 13A:1239(1982).Google Scholar
5.Siemens Analytical X-ray Instruments, Inc., 6300 Enterprise Lane, Madison, WI, U.S.A., STRESS-AT Software, 1990.Google Scholar