Applications of Dual-Energy X-ray Computed Tomography to Structural Ceramics*

Published online by Cambridge University Press:  06 March 2019

W. A. Ellingson
Affiliation:
Materials and Components Technology Division Argonne National Laboratory Argonne, Illinois 60439
M. W. Vannier
Affiliation:
Materials and Components Technology Division Argonne National Laboratory Argonne, Illinois 60439
Get access

Abstract

Advanced structural ceramics (Si3N4, SiC, A12O3, ZrO2) are rapidly being developed with sufficient fracture toughness to be considered for engineering applications such as internal combustion engine components, rotating turbine engine components, and heat recovery systems. X-ray computed tomography (CT) is a promising nondestructive evaluation method for these ceramics, but beam hardening presents a serious problem in the interpretation of CT images generated with polychromatic X-ray sources by creating artifacts . Dual-energy X-ray techniques have the potential to eliminate these problems. In addition, in theory, dual energy allows generation of quasimonochromatic equivalent images, which should allow verification of theoretically determined optimum energies. In using dual-energy methods, the high-and low-energy images are nonlinearly transformed to generate two energy-independent images characterizing the integrated Compton/photoelectric attenuation components. Characteristic linear combinations of these two "basis" images can serve to identify unknown materials and generate synthesized monoenergetic images.

The dual-energy method has been used to study structural ceramics as well as liquids that are close to ceramic materials in atomic number and mass density. The work was done on a Siemens DR-H CT machine with 85- and 125-kVp energy levels. Test samples included Si3N4 cylinders ranging from 10 to 50 mm in diameter, liquid Freon TF, and densified SiC.

Type
X. X-Ray Tomography, Imaging, and Topography
Copyright
Copyright © International Centre for Diffraction Data 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

**

Mallinckrodt Institute of Radiology/Washington University, St. Louis, MO.

*

Work supported by the U.S. Department of Energy, Assistant Secretary for Conservation and Renewable Energy, Office of Transportation Systems, as part of the Ceramic Technology for Advanced Heat Engines Project of the Advanced Materials Development Program (Contract ACK-85234).

References

1. Brooks, R.A. , DiChiro, G. , “Principles of Computer Assisted Tomography (CAT) in Radiographic and Radioisotopic Imaging,” Phys. Med, Biol. 21 689732 (1976).Google Scholar
2. Brooks, R.A. , DiChiro, G. , “Theory of Image Reconstruction in Computed Tomography,” Radiology 117, 561572 (1975).Google Scholar
3. Reimers, P. , Gilboy, W.B. , Goebbels, J. , “Recent Developments in the Industrial Application of Computerized Tomography with Ionizing Radiation,” NDT Int. 17, 197207 (1984).Google Scholar
4. Reimers, P. , Goebbels, J. , “New Possibilites of Nondestructive Evaluation by X-Ray Computed Tomography,” Mater. Eval. 41, 732737 (1983).Google Scholar
5. Persson, S. , Ostman, E. , The Use of Computed Tomography in Nondestructive Testing of Polymeric Materials, Aluminum and Concrete, SKEGA AB, Ersmark, Sweden, 1985.Google Scholar
6. Segal, E. , Notea, A. , Segal, Y. , “Dimensional Information Through Industrial Computerized Tomography,” Mater. Eval. 40, 12681279 (1982).Google Scholar
7. Gilboy, W.B. , Foster, J. , “Industrial Applications of Computerized Tomography with X- and Gamma-Radiation,” in Research Techniques in Nondestructive Testing, ed. Sharpe, R. S., Vol. 6, Academie Press, New York, 1982, pp. 255287.Google Scholar
8. Flannery, B.P. , Deckman, H.W. , Roberge, W.G. , D'Amico, K.L. , “Three-dimensionai Microtomography,” Science 237, 13891544 (1987).Google Scholar
9. Kinney, J.H. , Johnson, Bunse, Q.C., V. , Nichols, M.C. , Saroyan, R.A. , Nusshart, R. , Paul, R. , Brase, J.H. , “Three-dimensional X-Ray Computed Tomography in Materials Science,” Mater. Res. Soc. Bull. XIII (1), 1317 (1988).Google Scholar
10. Segal, E. , Ellingson, W.A. , Segal, Y. , Zmora, I. , “A Linearization Beam-Hardening Correction Method for X-Ray Computed Tomographie Imaging of Structural Ceramics,” in Review of Progress in Quantitative NDE (Proc. Conf. , Univ. of California, San Diego, August 3-8, 1986), ed, Thompson, D.O. and Chimenti, D. E., Vol. 6A, Plenum Press, New York, 1987, pp. 411-417.Google Scholar
11. Segal, E. , Eilingson, W.A. , “Beam-Hardening Correction Methods for Polychromatic X-Ray CT Scanners Used to Characterize Structural Ceramics,” in Nondestructive Characterization of Materials II (Proc. 2nd Intl. Symp. , Montreal. Canada, July 21-23, 1986), ed. Bussiere, J. F. et al. , Plenum Press, New York, 1987, pp. 169-173.Google Scholar
12. Sawicka, B.D. , Ellingson, W.A. , Photon CT Scanning of Advanced Ceramic Materials, Atomic Energy of Canada, Ltd. , Chalk River Nuclear Laboratory, Report AECL-9384, 1987.Google Scholar
13. Ellingson, W.A. , Segal, E. , Vannier, M.W. , X-Ray Computed Tomography for Structural Ceramic Applications: Beam Hardening Corrections, Argonne National Laboratory, Report ANL-87-24, May 1987.Google Scholar
14. Congress, U.S., Office of Technology Assessment, New Structural Materials Technologies: Opportunities for the Use of Advanced Ceramics and Composites - A Technical Memorandum, OTA-TH-E-32, U. S, Government Printing Office, Washington, DC, September 1986.Google Scholar
15. Kalender, W.A. , Perman, W.H. , Vetter, J.R. , Klotz, E. , “Evaluation of a Prototype Oual-Energy Computed Tomographie Apparatus: I. Phantom Studies,” Med. Phys. 13, 334339 (1986).Google Scholar
16. Lehmann, L.A. , Alvarez, R.E. , Macovski, A. , Brody, W.R. , Pelc, N.J. , Riederer, S.J. , Hall, A.L. , “Generalized Image Combination in Dual kVp Digital Radiography,” Med, Phys. 8, 659667 (1981).Google Scholar
17. Alvarez, R.E. , Macovski, A. , “Energy-Selective Reconstructions in X-Ray Computerized Tomography,” Phys. Med. Biol. 21, 733744 (1976).Google Scholar
18. Allemand, R. , “Basic Technological Aspects and Optimization Problems in X-Ray Computed Tomography,” in International Advanced Course on Physics and Engineering of Medical Imaging, Maratea, Italy, 1984, p. 11.Google Scholar