6 - The factors affecting X-ray intensities

Published online by Cambridge University Press:  11 January 2010

Michael M. Woolfson
Affiliation:
University of York
Get access

Summary

Diffraction from a rotating crystal

It has been seen that methods of recording X-ray intensities usually involve a crystal rotating in the incident X-ray beam. We shall now look at the problem of determining the total energy in a particular diffracted beam produced during one pass of the crystal through a diffracting position. In order to do this we must make some assumptions about the geometry of the diffraction process; the configuration we shall take is that the crystal is rotating about some axis with a constant angular velocity ω and that the incident and diffracted beams are both perpendicular to the axis of rotation.

Let us first look at the situation when we have a stationary crystal in a diffracting position. Associated with the crystal, and fixed relative to it, there is a reciprocal space within which is defined the Fourier transform, Fx(s), of the electron density of the crystal. For a theoretically perfect crystal of infinite extent the value of Fx(s) would be zero everywhere except at the nodes of a δ-function reciprocal lattice, the weight associated with the point (hkl) being (l/V)Fhkl. However, if the crystal is imperfect in some way there may be non-zero Fx(s) well away from the reciprocal-lattice points and for a finite crystal there will be a small region of appreciable Fx(s) around each of the reciprocal-lattice points. The imperfect-crystal case we shall not consider here but we shall be concerned with the size of the crystal, for this is a factor which must be present in every diffraction experiment.

Consider a crystal completely bathed in an incident beam of intensity Io.

Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×