Cold Temperature Preparation of XTEM Specimens of Embedded Metallic Nanoparticles

  • Bernt Johannessen (a1), David J. Llewellyn (a1), Patrick Kluth (a1) and Mark C. Ridgway (a1)

Extract

Nanoparticles (1-10 nm in diameter) are particularly susceptible to disorder, amorphization, deformation and/or dissolution upon ion irradiation as compared to their bulk counterparts, which is a consequence of the enhanced surface area to volume ratio of the former (structural disorder is often observed to be preferentially located at the surface). Synchrotron-radiation-based analytical techniques are ideally suited for the elucidation of structural perturbations as compared to the bulk material. Such techniques are commonly complemented by cross-sectional transmission electron microscopy (XTEM). XTEM offers invaluable information with respect to shape and morphology of the nanoparticles.

For the present work, Cu nanoparticles were synthesized within a 2 μm amorphous SiO2 matrix on a 520 μm Si support by ion implantation and thermal annealing following a procedure described elsewhere. In order to study the influence that ion irradiation has on the nanoparticles, the sample was then irradiated with 1x1015 ions / cm2 high-energy (5 MeV) Sn+ ions.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Cold Temperature Preparation of XTEM Specimens of Embedded Metallic Nanoparticles
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Cold Temperature Preparation of XTEM Specimens of Embedded Metallic Nanoparticles
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Cold Temperature Preparation of XTEM Specimens of Embedded Metallic Nanoparticles
      Available formats
      ×

Copyright

Corresponding author

References

Hide All
[1] Sun, D. Y., Gong, X. G., Wang, X.-Q., Phys. Rev. B 63 (2001) 193412.
[2] Johannessen, B., Kluth, P., Glover, C. J., Azevedo, G. de M., Llewellyn, D. J., Foran, G. J., and Ridgway, M. C., J. Appl. Phys. 98 (2005) 024307.
[3] Moller, W. and Eckstein, W., Nucl. Instrum. Meth. B 2 (1984) 814.
[4] Johannessen, B., Kluth, P., Llewellyn, D. J., Foran, G. J., Cookson, D. J., and Ridgway, M. C., Appl. Phys. Lett. 90 (2007) in press.
[5] The authors thank the Australian Research Council (ARC) for financial support.

Related content

Powered by UNSILO

Cold Temperature Preparation of XTEM Specimens of Embedded Metallic Nanoparticles

  • Bernt Johannessen (a1), David J. Llewellyn (a1), Patrick Kluth (a1) and Mark C. Ridgway (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.