Measurement of cerebral perfusion with arterial spin labeling: Part 1. Methods

  • THOMAS T. LIU (a1) and GREGORY G. BROWN (a2) (a3)

Abstract

Arterial spin labeling (ASL) is a magnetic resonance imaging (MRI) method that provides a highly repeatable quantitative measure of cerebral blood flow (CBF). As compared to the more commonly used blood oxygenation level dependent (BOLD) contrast-based methods, ASL techniques measure a more biologically specific correlate of neural activity, with the potential for more accurate estimation of the location and magnitude of neural function. Recent advances in acquisition and analysis methods have improved the somewhat limited sensitivity of ASL to perfusion changes associated with neural activity. In addition, ASL perfusion measures are insensitive to the low-frequency fluctuations commonly observed in BOLD experiments and can make use of imaging sequences that are less sensitive than BOLD contrast to signal loss caused by magnetic susceptibility effects. ASL measures of perfusion can aid in the interpretation of the BOLD signal change and, when combined with BOLD, can measure the change in oxygen utilization accompanying changes in behavioral state. Whether used alone to probe neural activity or in combination with BOLD techniques, ASL methods are contributing to the field's understanding of healthy and disordered brain function. (JINS, 2007, 13, 517–525.)

Copyright

Corresponding author

Correspondence and reprint requests to: Thomas T. Liu, Ph.D., Center for Functional Magnetic Resonance Imaging, University of California San Diego, 9500 Gilman Drive, MC 0677, La Jolla, CA, 92037-0677. E-mail: ttliu@ucsd.edu

References

Hide All

REFERENCES

Aguirre, G.K., Detre, J.A., & Wang, J. (2005). Perfusion fMRI for functional neuroimaging. International Review of Neurobiology, 66, 213236.
Aguirre, G.K., Detre, J.A., Zarahn, E., & Alsop, D.C. (2002). Experimental design and the relative sensitivity of BOLD and perfusion fMRI. NeuroImage, 15, 488500.
Alsop, D.C. (2005). Perfusion imaging of the brain: Contribution to clinical MRI. In R.R. Edelman, J.R. Hesselink, M.B. Zlatkin, & J.V. Cures III (Eds.), Clinical magnetic resonance imaging (3rd ed.), Vol. 1 (pp. 333357). Philadelphia: Saunders Elsevier.
Buxton, R.B. (2002). Introduction to functional Magnetic Resonance Imaging. Cambridge, UK: Cambridge University Press.
Buxton, R.B., Frank, L.R., Wong, E.C., Siewert, B., Warach, S., & Edelman, R.R. (1998a). A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magnetic Resonance in Medicine, 40, 383396.
Buxton, R.B., Wong, E.C., & Frank, L.R. (1998b). Dynamics of blood flow and oxygenation changes during brain activation: The balloon model. Magnetic Resonance in Medicine, 39, 855864.
Calamante, F., Thomas, D.L., Pell, G.S., Wiersma, J., & Turner, R. (1999). Measuring cerebral blood flow using magnetic resonance imaging techniques. Journal of Cerebral Blood Flow and Metabolism, 19, 701735.
Dale, A.M. & Buckner, R.L. (1997). Selective averaging of rapidly presented individual trials using fMRI. Human Brain Mapping, 5, 329340.
Davis, T.L., Kwong, K.K., Weisskoff, R.M., & Rosen, B.R. (1998). Calibrated functional MRI: Mapping the dynamics of oxidative metabolism. Proceedings of the National Academy of Science USA, 95, 18341839.
D'Esposito, M., Deouell, L.Y., & Gazzaley, A. (2003). Alterations in the BOLD fMRI signal with ageing and disease: A challenge for neuroimaging. Nature Reviews Neuroscience, 4, 863872.
Detre, J.A., Leigh, J.S., Williams, D.S., & Koretsky, A.P. (1992). Perfusion imaging. Magnetic Resonance in Medicine, 23, 3745.
Duhamel, G. & Alsop, D.C. (2004). Single-shot susceptibility insensitive whole brain 3D fMRI with ASL. Paper presented at the 12th ISMRM Scientific Meeting, Kyoto, Japan.
Duyn, J.H., Tan, C.X., van Gelderen, P., & Yongbi, M.N. (2001). High-sensitivity single-shot perfusion-weighted fMRI. Magnetic Resonance in Medicine, 46, 8894.
Edelman, R.R., Siewert, B., Darby, D.G., Thangaraj, V., Nobre, A.C., Mesulam, M.M., & Warach, S. (1994). Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology, 192, 513520.
Fernandez-Seara, M.A., Wang, J., Wang, Z., Rao, H., Guenther, M., Feinberg, D.A., & Detre, J.A. (2005). Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3T. Paper presented at the 13th ISMRM Scientific Meeting, Miami Beach, Florida, USA.
Garcia, D.M., Bazelaire, C.D., & Alsop, D. (2005). Pseudo-continuous flow drive adiabatic inversion for arterial spin labeling. Paper presented at the 13th ISMRM Scientific Meeting, Miami Beach, Florida, USA.
Guyton, A.C. (1977). Basic human physiology: Normal function and mechanisms of disease (2nd ed.). Philadelphia: W. B. Saunders Company.
Hernandez-Garcia, L., Lee, G.R., Vazquez, A.L., Yip, C.Y., & Noll, D.C. (2005). Quantification of perfusion fMRI using a numerical model of arterial spin labeling that accounts for dynamic transit time effects. Magnetic Resonance in Medicine, 54, 955964.
Hoge, R.D., Atkinson, J., Gill, B., Crelier, G.R., Marrett, S., & Pike, G.B. (1999). Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex. Proceedings of the National Academy of Science USA, 96, 94039408.
Hyder, F. (2004). Neuroimaging with calibrated FMRI. Stroke, 35 (Suppl. 1), 26352641.
Kim, S.-G. & Duong, T.Q. (2002). Mapping cortical columnar structures using fMRI. Physiology & Behavior, 77, 641644.
Kim, S.-G. & Tsekos, N.V. (1997). Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging. Magnetic Resonance in Medicine, 37, 425435.
Kwong, K.K., Chesler, D.A., Weisskoff, R.M., Donahue, K.M., Davis, T.L., Ostergaard, L., Campbell, T.A., & Rosen, B.R. (1995). MR perfusion studies with T1-weighted echo planar imaging. Magnetic Resonance in Medicine, 34, 87887.
Liu, T.T. & Wong, E.C. (2005). A signal processing model for arterial spin labeling functional MRI. NeuroImage, 24, 207215.
Liu, T.T., Wong, E.C., Frank, L.R., & Buxton, R.B. (2002). Analysis and design of perfusion-based event-related fMRI experiments. NeuroImage, 16, 269282.
Lu, H., Golay, X., Pekar, J.J., & Van Zijl, P.C. (2004). Sustained poststimulus elevation in cerebral oxygen utilization after vascular recovery. Journal of Cerebral Blood Flow and Metabolism, 24, 764770.
Luh, W.M., Wong, E.C., Bandettini, P.A., Ward, B.D., & Hyde, J.S. (2000). Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation with T(1)-based tissue identification. Magnetic Resonance in Medicine, 44, 137143.
Kemeny, S., Ye, F.Q., Birn, R., & Braun, A.R. (2005). Comparison of continuous overt speech fMRI using BOLD and arterial spin labeling. Human Brain Mapping, 24, 173183.
Meier, P. & Zierler, K.L. (1954). On the theory of the indicator-dilution method for measurement of blood flow and volume. Journal of Applied Physiology, 6, 731744.
Miller, K.L., Luh, W.M., Liu, T.T., Martinez, A., Obata, T., Wong, E.C., Frank, L.R., & Buxton, R.B. (2001). Nonlinear temporal dynamics of the cerebral blood flow response. Human Brain Mapping, 13, 112.
Mumford, J.A., Hernandez-Garcia, L., Lee, G.R., & Nichols, T.A. (2006). Estimation efficiency and statistical power in arterial spin labeling fMRI. NeuroImage, 33, 103114.
Obata, T., Liu, T.T., Miller, K.L., Luh, W.M., Wong, E.C., Frank, L.R., & Buxton, R.B. (2004). Discrepancies between BOLD and flow dynamics in primary and supplementary motor areas: Application of the balloon model to the interpretation of BOLD transients. NeuroImage, 21, 144153.
Ogawa, S., Lee, T.-M., Stepnoski, R., Chen, W., Zhu, X.-H., & Ugurbil, K. (2000). An approach to probe some neural systems interaction by functional MRI at neural time scale down to milliseconds. Proceedings of the National Academy of Science. USA, 97, 1102611031.
Parkes, L.M. (2005). Quantification of cerebral perfusion using arterial spin labeling: Two-compartment models. Journal of Magnetic Resonance Imaging, 22, 732736.
Parkes, LM. & Tofts, P.S. (2002). Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability. Magnetic Resonance in Medicine, 48, 2741.
Restom, K., Behzadi, Y., & Liu, T.T. (2006). Physiological noise reduction for arterial spin labeling functional MRI. NeuroImage, 31, 11041115.
Roy, C.S. & Sherrington, C.S. (1890). On the regulation of the blood-supply of the brain. The Journal of Physiology, 11, 85108.
St. Lawrence, K.S., Frank, J.A., Bandettini, P.A., & Ye, F.Q. (2005). Noise reduction in multi-slice arterial spin tagging imaging. Magnetic Resonance in Medicine, 53, 735738.
Tjandra, T., Brooks, J.C., Figueiredo, P., Wise, R., Matthews, P.M., & Tracey, I. (2005). Quantitative assessment of the reproducibility of functional activation measured with BOLD and MR perfusion imaging: Implications for clinical trial design. NeuroImage, 27, 393401.
Wang, J., Aguirre, G.K., Kimberg, D.Y., Roc, A.C., Li, L., & Detre, J.A. (2003). Arterial spin labeling perfusion fMRI with very low task frequency. Magnetic Resonance in Medicine, 49, 796802.
Wang, J., Rao, H., Wetmore, G.S., Furlan, P.M., Korczykowski, M., Dinges, D.F., & Detre, J.A. (2005). Perfusion functional MRI reveals cerebral blood flow pattern under psychological stress. Proceedings of the National Academy of Sciences, USA, 102, 1780417809.
Warner, D.S., Kassell, N.F., & Boarini, D.J. (1987). Microsphere cerebral blood flow determination. In J.H. Wood (Ed.), Cerebral blood flow: Physiologic and clinical aspects (pp. 288298). New York: McGraw-Hill Company.
Williams, D.S., Detre, J.A., Leigh, J.S., & Koretsky, A.P. (1992). Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proceedings of the National Academy of Science USA, 89, 212216.
Wintermark, M., Sesay, M., Barbier, E., Borbely, K., Dillon, W.P., Eastwood, J.D., Glenn, T.C., Grandin, C.B., Pedraza, S., Soustiel, J.F., Nariai, T., Zaharchuk, G., Caille, J.M., Dousset, V., & Yonas, H. (2005). Comparative overview of brain perfusion imaging techniques. Journal of Neuroradiology, 32, 294314.
Wong, E.C., Buxton, R.B., & Frank, L.R. (1997). Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR in Biomedicine, 10, 237249.
Wong, E.C., Buxton, R.B., & Frank, L.R. (1998a). Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magnetic Resonance in Medicine, 39, 702708.
Wong, E.C., Buxton, R.B., & Frank, L.R. (1998b). A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magnetic Resonance in Medicine, 40, 348355.
Wong, E.C., Cronin, M., Wu, W.C., Inglis, B., Frank, L.R., & Liu, T.T. (2006). Velocity-selective arterial spin labeling. Magnetic Resonance in Medicine, 55, 13341341.
Wong, E.C., Liu, T.T., Frank, L.R., & Buxton, R.B. (2001). Close tag, short TR continuous ASL for functional brain mapping: High temporal resolution ASL with a BOLD sized signal at 1.5T. Paper presented at the Ninth Meeting, International Society for Magnetic Resonance in Medicine, Glasgow, Scotland, UK.
Wong, E.C., Luh, W.M., & Liu, T.T. (2000). Turbo ASL: Arterial spin labeling with higher SNR and temporal resolution. Magnetic Resonance in Medicine, 44, 511515.
Woolrich, M.W., Chiarelli, P., Gallichan, D., Perthen, J., & Liu, T.T. (2006). Inferring blood volume, blood flow, and blood oxygenation changes from functional ASL data. Magnetic Resonance in Medicine, 56, 891906.
Ye, F.Q., Matay, V.S., Jezzard, P., Frank, J.A., Weinberger, D.R., & McLaughlin, A.C. (1997). Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magnetic Resonance in Medicine, 37, 226235.

Keywords

Related content

Powered by UNSILO

Measurement of cerebral perfusion with arterial spin labeling: Part 1. Methods

  • THOMAS T. LIU (a1) and GREGORY G. BROWN (a2) (a3)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.