We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To measure directly the rate of contamination, during routine patient examination, of gowns, gloves, and stethoscopes with vancomycin-resistant enterococci (VRE).
Setting:
A large, academic, tertiary-care hospital.
Patients:
Between January 1997 and December 1998, 49 patients colonized or infected with VRE were entered in the study.
Design:
After routine examination, the examiner's glove fingertips, gown (the umbilical region and the cuffs), and stethoscope diaphragm were pressed onto Columbia colistin-nalidixic acid (CNA) agar plates with 5% sheep blood plus vancomycin 6 ug/mL. The stethoscope diaphragm was sampled again after cleaning with a 70% isopropanol wipe.
Results:
VRE were isolated from at least 1 examiner site (gloves, gowns, or stethoscope) in 33 (67%) of 49 cases. Gloves were contaminated in 63%, gowns in 37%, and stethoscopes in 31%. All three items were positive for VRE in 24%. One case each had stethoscope and gown contamination without glove contamination. Only 1 (2%) of 49 stethoscopes was positive after wiping with an alcohol swab. Contamination at any site was more likely when the patient had a colostomy or ileostomy. Patients identified by rectal-swab culture alone were as likely to contaminate their examiners as were those identified by clinical specimens.
Conclusions:
Our study revealed a high rate of examiner contamination with VRE. The similar risk of contamination identified by surveillance and clinical cases reinforces concerns that patients not known to be colonized with VRE could serve as sources for dissemination. Wiping with alcohol is effective in decontaminating stethoscopes.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.