We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure coreplatform@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The American Heart Association (AHA; Dallas, Texas USA) and European Resuscitation Council (Niel, Belgium) cardiac arrest (CA) guidelines recommend the intraosseous (IO) route when intravenous (IV) access cannot be obtained. Vasopressin has been used as an alternative to epinephrine to treat ventricular fibrillation (VF).
Hypothesis/Problem
Limited data exist on the pharmacokinetics and resuscitative effects of vasopressin administered by the humeral IO (HIO) route for treatment of VF. The purpose of this study was to evaluate the effects of HIO and IV vasopressin, on the occurrence, odds, and time of return of spontaneous circulation (ROSC) and pharmacokinetic measures in a swine model of VF.
Methods
Twenty-seven Yorkshire-cross swine (60 to 80 kg) were assigned randomly to three groups: HIO (n=9), IV (n=9), and a control group (n=9). Ventricular fibrillation was induced and untreated for two minutes. Chest compressions began at two minutes post-arrest and vasopressin (40 U) administered at four minutes post-arrest. Serial blood specimens were collected for four minutes, then the swine were resuscitated until ROSC or 29 post-arrest minutes elapsed.
Results
Fisher’s Exact test determined ROSC was significantly higher in the HIO 5/7 (71.5%) and IV 8/11 (72.7%) groups compared to the control 0/9 (0.0%; P=.001). Odds ratios of ROSC indicated no significant difference between the treatment groups (P=.68) but significant differences between the HIO and control, and the IV and control groups (P=.03 and .01, respectively). Analysis of Variance (ANOVA) indicated the mean time to ROSC for HIO and IV was 621.20 seconds (SD=204.21 seconds) and 554.50 seconds (SD=213.96 seconds), respectively, with no significant difference between the groups (U=11; P=.22). Multivariate Analysis of Variance (MANOVA) revealed the maximum plasma concentration (Cmax) and time to maximum concentration (Tmax) of vasopressin in the HIO and IV groups was 71753.9 pg/mL (SD=26744.58 pg/mL) and 61853.7 pg/mL (SD=22745.04 pg/mL); 111.42 seconds (SD=51.3 seconds) and 114.55 seconds (SD=55.02 seconds), respectively. Repeated measures ANOVA indicated no significant difference in plasma vasopressin concentrations between the treatment groups over four minutes (P=.48).
Conclusions
The HIO route delivered vasopressin effectively in a swine model of VF. Occurrence, time, and odds of ROSC, as well as pharmacokinetic measurements of HIO vasopressin, were comparable to IV.
BurgertJM, JohnsonAD, Garcia-BlancoJ, FultonLV, LoughrenMJ. The Resuscitative and Pharmacokinetic Effects of Humeral Intraosseous Vasopressin in a Swine Model of Ventricular Fibrillation. Prehosp Disaster Med. 2017;32(3):305–310.
Obtaining intravenous (IV) access in patients in hemorrhagic shock is often difficult and prolonged. Failed IV attempts delay life-saving treatment. Intraosseous (IO) access may often be obtained faster than IV access. Albumin (5%) is an option for prehospital volume expansion because of the absence of interference with coagulation and platelet function.
Hypothesis/Problem
There are limited data comparing the performance of IO and IV administered 5% albumin. The aims of this study were to compare the effects of tibial IO (TIO) and IV administration of 500 mL of 5% albumin on infusion time and hemodynamic measurements of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and stroke volume (SV) in a swine model of hemorrhagic shock.
Methods
Sixteen male swine were divided into two groups: TIO and IV. All subjects were anesthetized and a Class III hemorrhage was achieved by exsanguination of 31% of estimated blood volume (EBV) from a femoral artery catheter. Following exsanguination, 500 mL of 5% albumin was administered under pressurized infusion (300 mmHg) by the TIO or IV route and infusion time was recorded. Hemodynamic measurements of HR, MAP, CO, and SV were collected before and after exsanguination and every 20 seconds for 180 seconds during 5% albumin infusion.
Results
An independent t-test determined that IV 5% albumin infusion was significantly faster compared to IO (P=.01). Mean infusion time for TIO was seven minutes 35 seconds (SD=two minutes 44 seconds) compared to four minutes 32 seconds (SD=one minute 08 seconds) in the IV group. Multivariate Analysis of Variance was performed on hemodynamic data collected during the 5% albumin infusion. Analyses indicated there were no significant differences between the TIO and IV groups relative to MAP, CO, HR, or SV (P>.05).
Conclusion
While significantly longer to infuse 5% albumin by the TIO route, the longer TIO infusion time may be negated as IO devices can be placed more quickly compared to repeated IV attempts. The lack of significant difference between the TIO and IV routes relative to hemodynamic measures indicate the TIO route is a viable route for the infusion of 5% albumin in a swine model of Class III hemorrhage.