We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure coreplatform@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The National Healthcare Safety Network surgical site infections risk models for hip (HPRO) and knee (KPRO) replacement are intended for case-mix adjustment when reporting surgical site infection rates across institutions, but they are not validated in external data sets
Objective.
To evaluate the validity of HPRO and KPRO risk models and improvement in risk prediction with inclusion of information on morbid obesity and diabetes mellitus.
Design.
Retrospective cohort study.
Patients.
A single-center cohort of 21,941 hip and knee replacement procedures performed between 2002 and 2009.
Methods.
Discriminative ability was assessed using the concordance statistic (C statistic). Calibration was assessed using the Hosmer-Lemeshow goodness-of-fit tests.
Results.
The discrimination of HPRO was good, with a C statistic of 0.695 for surgical site infections and 0.749 for prosthetic joint infections. The discrimination of KPRO was worse than that of HPRO, with a C statistic of 0.592 for surgical site infections and 0.675 for prosthetic joint infections. Adding morbid obesity and diabetes mellitus to the HPRO and KPRO risk models modestly improved discrimination. There was no significant evidence of miscalibration based on the Hosmer-Lemeshow tests, but calibration of HPRO models appeared to be better than that of the KPRO models.
Conclusions.
HPRO performed better than the KPRO in predicting surgical site infections after hip and knee replacements. Both fared well in predicting prosthetic joint infections.
Infect Control Hosp Epidemiol 2014;35(11):1323–1329