We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure coreplatform@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To characterize the presence and magnitude of viruses in the air and on surfaces in the rooms of hospitalized patients with respiratory viral infections, and to explore the association between care activities and viral contamination.
Design:
Prospective observational study.
Setting:
Acute-care academic hospital.
Participants:
In total, 52 adult patients with a positive respiratory viral infection test within 3 days of observation participated. Healthcare workers (HCWs) were recruited in staff meetings and at the time of patient care, and 23 wore personal air-sampling devices.
Methods:
Viruses were measured in the air at a fixed location and in the personal breathing zone of HCWs. Predetermined environmental surfaces were sampled using premoistened Copan swabs at the beginning and at the end of the 3-hour observation period. Preamplification and quantitative real-time PCR methods were used to quantify viral pathogens.
Results:
Overall, 43% of stationary and 22% of personal air samples were positive for virus. Positive stationary air samples were associated with ≥5 HCW encounters during the observation period (odds ratio [OR], 5.3; 95% confidence interval [CI], 1.2–37.8). Viruses were frequently detected on all of the surfaces sampled. Virus concentrations on the IV pole hanger and telephone were positively correlated with the number of contacts made by HCWs on those surfaces. The distributions of influenza, rhinoviruses, and other viruses in the environment were similar.
Conclusions:
Healthcare workers are at risk of contracting respiratory virus infections when delivering routine care for patients infected with the viruses, and they are at risk of disseminating virus because they touch virus-contaminated fomites.
To characterize the magnitude of virus contamination on personal protective equipment (PPE), skin, and clothing of healthcare workers (HCWs) who cared for patients having acute viral infections.
Design:
Prospective observational study.
Setting:
Acute-care academic hospital.
Participants:
A total of 59 HCWs agreed to have their PPE, clothing, and/or skin swabbed for virus measurement.
Methods:
The PPE worn by HCW participants, including glove, face mask, gown, and personal stethoscope, were swabbed with Copan swabs. After PPE doffing, bodies and clothing of HCWs were sampled with Copan swabs: hand, face, and scrubs. Preamplification and quantitative polymerase chain reaction (qPCR) methods were used to quantify viral RNA copies in the swab samples.
Results:
Overall, 31% of glove samples, 21% of gown samples, and 12% of face mask samples were positive for virus. Among the body and clothing sites, 21% of bare hand samples, 11% of scrub samples, and 7% of face samples were positive for virus. Virus concentrations on PPE were not statistically significantly different than concentrations on skin and clothing under PPE. Virus concentrations on the personal stethoscopes and on the gowns were positively correlated with the number of torso contacts (P < .05). Virus concentrations on face masks were positively correlated with the number of face mask contacts and patient contacts (P < .05).
Conclusions:
Healthcare workers are routinely contaminated with respiratory viruses after patient care, indicating the need to ensure that HCWs complete hand hygiene and use other PPE to prevent dissemination of virus to other areas of the hospital. Modifying self-contact behaviors may decrease the presence of virus on HCWs.