We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure coreplatform@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To describe two cases of nosocomial legionellosis and discuss the epidemiology of this infection.
Design:
Potable water was collected from multiple sites. Patient and environmental isolates were characterized by the Legionella slide agglutination test and monoclonal antibody subtyping. Concordance among isolates was confirmed by pulsed-field gel electrophoresis (PFGE).
Setting:
A 713-bed university-affiliated hospital.
Results:
There was widespread contamination of potable water with Legionella pneumophila during a period of major construction; cooling towers were without growth of Legionella. One patient's isolate was the same by PFGE as the environmental isolate collected from the water faucet in his room. Control measures included superheating water used in all patient care areas to 75°C for 72 hours and flushing superheated water through faucets and showers; cleaning shower heads with a sonicator washer; and raising the hot water storage tank temperature from 43°C to 52°C. After these interventions, repeat environmental cultures over the next 6 months were without growth of Legionella, and no further cases of nosocomial legionnaires' disease were documented. An association between legionnaires' disease and construction is postulated. Heightened surveillance and preventive measures may be warranted during periods of excavation on hospital grounds or when potable water supplies are otherwise shut down and later repressurized.