Hostname: page-component-cd9895bd7-dk4vv Total loading time: 0 Render date: 2024-12-30T16:15:22.729Z Has data issue: false hasContentIssue false

Energy in buildings—Policy, materials and solutions

Published online by Cambridge University Press:  30 October 2017

Matthias M. Koebel*
Affiliation:
Building Energy Materials and Components Laboratory, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
Jannis Wernery
Affiliation:
Building Energy Materials and Components Laboratory, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
Wim J. Malfait
Affiliation:
Building Energy Materials and Components Laboratory, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland
*
a)Address all correspondence to Matthias M. Koebel at matthias.koebel@empa.ch

Abstract

This manuscript provides a bird’s eye view on energy in buildings. We discuss how energy policy leads to building standards that affect innovation in the building sector. We review current and future materials and solutions for the building envelope (insulation and glazing), renewable energy generation and energy storage, and demonstrate how the integration of buildings into district networks mitigates problems arising from a building’s, and its users’, dynamic behavior.

Buildings account for ∼40% of global energy demands, and the increased adoption of innovative solutions for buildings represents an enormous potential to reduce energy demands and greenhouse gas emissions. Here, we critically review the current and future materials and solutions for the construction sector. We describe how policy affects innovative businesses and the adoption of new products and solutions. We investigate how the building envelope and user behavior determine building energy demands. Compared to conventional solutions, superinsulation materials (vacuum insulation panels, silica aerogel) can achieve the same thermal performance with drastically thinner insulation. With low-emissivity coatings and appropriate filler gasses, double and triple glazing reduces thermal losses by an order of magnitude. Vacuum and aerogel glazing reduce these even further. Switchable glazing solutions maximize solar gains during wintertime and minimize illumination demands whilst avoiding overheating in summer. Upon integration of renewable energy systems, buildings become both producers and consumers of energy. Combined with the dynamic user behavior, temporal variations in energy production require thermal and electrical storage and the integration of buildings into smart grids and energy district networks. The combination of these measures can reduce the energy consumption of the building’s stock by a factor of three.

Type
Review
Copyright
Copyright © Materials Research Society 2017 

DISCUSSION POINTS

  • Can policy convince stakeholders, building owners, and users to improve building energy efficiency?

  • How do current building materials and technologies complement each other toward building energy efficiency?

  • Which new materials and solutions are likely to have a strong impact in the building sector?

Background and global context

Society is facing drastic environmental and geopolitical impacts from climate change. There is evidence for significant acceleration of global warming, and experts warn of a point of no return calling for CO2 emissions to be stabilized. To turn the world’s energy infrastructure and systems around in time before the most detrimental climate change effects can no longer be undone, Reference Parmesan and Yohe1 passionate policy makers must meet innovative engineers and entrepreneurs because the implementation of innovative solutions relies heavily on both the economic and the political landscape.

First off, climate change must be perceived as a problem to create the necessary political pressure needed for policy changes. But who makes the public opinion of global warming? At the end of the 1980s, the greenhouse effect made frontline news following a testimony at a U.S. senate climate hearing. Reference Christianson2 Despite the broad consensus of international experts on climate change, Reference Easterling, Meehl, Parmesan, Changnon, Karl and Mearns3,Reference Menzel, Sparks, Estrella, Koch, Aasa, Ahas, Alm-Kübler, Bissolli, Braslavská and Briede4 there was a strong, well-organized opposition (think-tanks, scientists with contrary positions) which began to question the mere existence of climate change, effectively stopping all efforts of the US government to impose CO2 emission regulations for a decade. Reference McCright and Dunlap5 Many of these activities were directly supported by the fossil fuel industry, which has a strong interest in playing down the effects of climate change. With the current political climate in the US, the same debate has again become a topic of great actuality and consequence, and scientist and experts worldwide have an obligation to take an active counter position in this postfactual age. Given today’s very visible consequences of climate change, e.g., weather extremes Reference Coumou and Rahmstorf6 and arctic record temperatures in 2016, most people have by now accepted that climate change is real and that it poses a significant risk to the continuation of life as we know it, but different groups of people worry in different ways about the possible consequences (nature and landscape, devastation, resource availability, diseases). For example, most Americans still think the consequences will primarily concern people from other continents or wildlife in general. Reference Leiserowitz7 Another study on the public perception in Europe shows that Northern Europeans are less concerned than Southern Europeans, commensurate with an increase in the expected comfort or discomfort (desired warmer weather versus too hot climate) resulting from global warming. When zooming in to a more local resolution, issues linked to effects on daily life seem to dominate, namely land erosion, flooding, and inability to qualify for insurance coverage etc. Reference Lorenzoni and Pidgeon8

Second, we must turn our attention toward mitigation, and more specifically toward the role of policy and regulation changes. Reference Haines, Smith, Anderson, Epstein, McMichael, Roberts, Wilkinson, Woodcock and Woods9 Generally, policy influences the real world in two ways, namely, (i) by providing a long-term roadmap and strategy that sets the overall goals of a society and (ii) to implement norms and standards needed to put the said strategy into action. In reality, political and industrial stakeholders are often closely related through political processes and mutual interests. Such concentration of power and mutual influencing can lead to serious adverse effects, e.g., “non-believers” and political stalemate situations leading to delayed action. The United States plays a central role in the discussion about climate change mitigation because of (i) its strong economic position and (ii) the role model character for second and third world countries in their quest for economic growth and success. This second point has a considerable influence on the energy policy of developing countries. In that sense, unfortunately, the strong economic focus of the US does not always send out the right signals to second and third world countries. Europe has been taking the climate change issue more seriously, most likely due to a stronger ecologist and left-wing influence in the political and public opinion and less direct influence of the petroleum industry in the government’s decision making processes. The effect is seen by example of (i) the relatively early policy measures taken by the EU government (Table 1), (ii) the wide adaptation of climate targets by its membership countries, Reference Biesbroek, Swart, Carter, Cowan, Henrichs, Mela, Morecroft and Rey10,Reference Tompkins, Adger, Boyd, Nicholson-Cole, Weatherhead and Arnell11 and (iii) the promising results in the form of CO2 savings, a substantial increase in renewable energy production, etc. (Table 2).

Table 1. Climate change programs at global, regional and national levels.

Table 2. Primary energy consumption for the years 1995/2005/2015 based on the Enerdata Statistical Yearbook. 13

The climate change programs in Table 1 target to limit global warming to acceptable levels. The opinion of leading experts is that the anthropogenic emissions-based temperature increase has to be kept below 2 °C if a self-accelerating “runoff” scenario is to be avoided. Reference Meinshausen, Meinshausen, Hare, Raper, Frieler, Knutti, Frame and Allen12 This means limiting cumulative global CO2 emissions in the 2000–2050 period to 1000 Gtons or 1440 Gtons to yield a 50 and 25% probability, respectively, to stay within the 2 °C limit.

Since the advent of the Kyoto Protocol, most industrialized countries have attempted to reduce their CO2 emissions and oil consumption and to increase the fraction of electricity harvested from renewable sources. Again, we see the role model example of European countries like Sweden, Germany, and Spain (Table 2). On average, 2015 CO2 emissions from these countries are roughly 15% lower than in 1995. Because of the late participation and ineffectual commitment of the American continent, both North and South America are still significantly lagging behind on their Kyoto protocol targets. Total energy consumption has gone up by roughly 20–30% in North America and by a factor of two in Brazil. The increased energy consumption of Brazil tracks the strong economic growth over the last decade. CO2 emissions in North America are nearing stabilization, although some of this “success” must be attributed to the subprime economic crisis and its ensuing recession. The effect of the 2008 economic crisis on emissions also affects the emissions of the EU and Japan. Asia, as the world’s commodities production factory, is experiencing a massive energy infrastructure ramp-up with rising energy consumption and greenhouse gas emissions, with the exception of Japan. Nevertheless, it must be noted that China takes its pollution problems very seriously and is making massive investments in electrical energy, vehicles, and transportation as well as production from renewable sources. Reference He, Xu, Pang, Tian and Wu14 In Russia, energy consumption is still increasing, but CO2 output is stabilizing. In the Middle East, fossil fuel-based electrification of infrastructures has led to an almost doubling of emissions since 1995.

Policy as a link between political leaders and innovative businesses

To better understand the different adoption rates of climate action programs such as the Kyoto protocol in different parts of the World, one must realize the balance of power between short-term economic profit taking and long-term socioeconomic interest. From an economic point of view, a rebuild of the energy sector requires tremendous investments and risks taken along the entire value chain, by investors, distributors, and, importantly, early adopter consumers. This is particularly important for the building and construction sector, which is inherently conservative because of the long service life and large up-front investments. Policy can help drive the transition forward, but often also has unintended consequences. In Germany, the federal parliament has set the tone for over two decades with a renewable energy policy, often against reluctant governments and the vehement opposition from the nuclear and coal industry. Reference Jacobsson and Lauber15 The sustained support for renewable energy, including massive subsidies for wind and solar electricity in the form of feed-in tariff incentives, has increased the share of renewables in Germany’s electricity mix by a factor of more than five between 1995 and 2015, leading to a substantial reduction in CO2 emissions (Table 2). In addition, the emergence of a mass market has drastically reduced the cost of PV. The record-breaking adoption of wind and PV technology in Germany contrasts with the situation in Japan, where the concentration on nuclear energy led to a decline of the Japanese PV market. Reference Chowdhury, Sumita, Islam and Bedja16 On the downside, Germany’s top-down focus on short-term consumer cost rather than total cost and market formation, Reference Lauber and Jacobsson17 left the market too dependent on subsidies, leading to a solar industry bubble. In addition to top-down policy measures, bottom-up innovation by businesses that couple risk with technological feasibility, can transform the energy market. For example, the success of Tesla Motors, driven by technological improvements on key bottle necks (range and charging times) and an innovative but risky direct-to-consumer business model, has changed the perception of the practicality and viability of electric vehicles not only from the general public but also from traditional car manufacturers.

Global building standards and policy

Buildings account for roughly 40% of the global energy demand, Reference Ürge-Vorsatz, Cabeza, Serrano, Barreneche and Petrichenko18 with changing energy demands due to climate change. Reference Roberts19 The other two main energy intensive sectors are transportation (∼25%) and industry (∼25%). The transportation sector, particularly the automotive business, has been continuously increasing efficiency of drivetrains over the past two decades so that additional new savings come at a comparably higher price. Industry and services also offer only limited potential for efficiency gains without compromising competitiveness of first world countries with stricter environmental laws. The potential for energy demand reduction in buildings is a popular research and discussion topic nowadays. Despite a general tightening of building energy codes around the world, Reference Pongiglione and Calderini20 the degree of implementation of various state-of-the-art technologies and solutions varies significantly from continent to continent and from country to country. When trying to assess the overall saving potential in buildings, the discussion must not always be led by a comparison of similar building types (residential, commercial, old, energy retrofitted, new) but also must be based on location and climate. Generally, buildings in northern climates have a higher overall energy demand and CO2 output because of the dominant heating demand which is most commonly powered by fossil fuel combustion. In warmer climates, the higher cooling loads are most often covered by chillers operating with electrical energy.

In an attempt to better understand the existing building stock in different parts of the world, we summarize the currently implemented state-of-the-art technical solutions and compare them to the respective energy savings potential. Table 3, shows a semiquantitative market analysis and suggested energy saving measures, based on various national policy studies. Reference LaFrance2132 Efficient building envelopes with double or triple glazing, insulated walls, and a high degree of air tightness are standard in Europe, less so on the American continent, and adopted to an even smaller extent in Asia and in the rest of the world. Particularly airtight building envelopes are standard for new construction in Europe but not really for the rest of the world. According to Haines et al., Reference Haines, Smith, Anderson, Epstein, McMichael, Roberts, Wilkinson, Woodcock and Woods9 potential energy and CO2 savings in the built environment on the order of 30% can be achieved by 2020 in a cost-effective manner with relatively minor intervention. The deep-retrofitting potential on a single building scale can be by far higher (65–80%) but with a high initial investment. Because many older buildings are built with older technology, e.g., poor windows and insulation standards, oil or coal heating systems, roughly 80% of buildings nowadays offer a sizable retrofitting potential.

Table 3. Currently implemented technologies and measures with the largest energy savings potential, modified from Ref. Reference Ürge-Vorsatz and Novikova33.

–Not implemented/no market.

*Initial market.

**Established market.

***Mature market.

DG: double glazing, TG: triple glazing.

Building envelope

The building envelope constitutes the separation between the interior and exterior of a building, i.e., between the conditioned and the unconditioned environment and has three main functions: (i) structure, (ii) control, and (iii) aesthetics. In many building styles, the envelope is a load-bearing part of the building and has to be designed accordingly. The building envelope controls the transfer of some or all of the following, depending on location, climate, and culture: heat, light, air, water, sound, fire, and inhabitants (safety), and the appropriate regulation of all of these factors is necessary to achieve a comfortable indoor environment. With respect to the energy usage of the building, the first three of those control functions, i.e., heat, light, and air, are the most relevant. Finally, the building envelope needs to satisfy aesthetic demands with respect to both external and internal surfaces. In the last few years, a fourth function of the building envelope has emerged, namely, (iv) the production of renewable energy through solar panels.

Historical evolution of the building envelope

The building envelope has always served the three main functions of structure, control, and aesthetics, but the construction techniques and materials have changed over the centuries. A good overview on the historical evolution of energy-efficient buildings is given by Ionescu et al. Reference Ionescu, Baracu, Vlad, Necula and Badea34 The earliest known, earth-sheltered, green-roofed buildings from 5000 B.C. were found in a Neolithic village on the Orkney Islands, Scotland, and similar dwellings existed in other areas with a cold climate. Reference Bozsaky35 In warm regions, already in 4000 B.C., the Persians used “wind towers” to lead cool air from underground water canals over the “building envelope”. Reference A’zami36 About 3100 B.C., ancient Egyptian builders used the insulating properties and heat capacity of thick brick walls to keep their buildings cool. They also made use of cavity walls for insulation—an approach that was later adopted by the ancient Greeks around 500 B.C. In Greece, the orientation of houses, the “Socratic house”, usually was toward the South to gain solar energy. About a hundred years later, in 400 B.C., the Romans started to use wall heating, the so-called “hypocausts”. Reference Ionescu, Baracu, Vlad, Necula and Badea34 Natural materials like reed, eelgrass, straw, etc., were used in many subsequent building styles to thermally separate the interior from the exterior. Thus, the main functional aspects of the envelope, namely, insulation, thermal mass, ventilation, and solar gains, were already established in antiquity. The next major conceptual advances came in the 19th century with the growing understanding of thermodynamics in terms of heat transfer and thermal insulation. These led to double pane windows as early as 1865, Reference Stetson37 the exploration of moisture transport in building elements in the 1890s, and the employment of the enthalpy–humidity diagram for the description of comfort zones in 1923. The first modern buildings focused on passive solar gains were built with the “House of Tomorrow” in 1933 38 and the MIT Solar House #1 in 1939. 39 The 1960s saw the advent of computer simulations to predict thermal load and performance of buildings Reference Kusuda40 as well as the seminal work of Povl Ole Fanger for the development of a standard thermal comfort model. Reference Van Hoof41 The oil crisis in 1973 created a strong focus on building energy efficiency, taking into account air tightness, super-insulation [in the old sense of the definition as “extra thick insulation layers”, the modern one referring to insulation materials with thermal conductivity values below 0.02 W/(m K)], heat recovery ventilation, triple glazing, and passive solar technologies. The concept of a zero-energy house was explored by many prominent projects such as the “Phillips Experimental House” (1975), the DTH zero-energy house (1975), the “Lo-Cal House” (1976), and the “Leger House” (1977). Reference Ionescu, Baracu, Vlad, Necula and Badea34 Inspired by these advances, the idea of the “Passive House”—a building in which heat losses are reduced to a minimum by a highly insulated envelope—was developed in the late 1980s and implemented for the first time in the “Passive House Kranichstein” in 1991. Reference Feist and Schnieders42 Accompanying a high-performance building envelope with integrated photovoltaic panels and a seasonal energy storage, an energy-autonomous single-family house—the Self sufficient Solar House—was realized in 1992 in Freiburg. Reference Voss, Goetzberger, Bopp, Häberle, Heinzel and Lehmberg43 In 1995, “Passivhaus” became a standard in Germany for low-energy use buildings based on an air-tight, highly insulated thermal envelope in combination with mechanical heat recovery ventilation systems. Already a year earlier, a similar standard, the “Minergie” label, had been created in Switzerland.

Construction techniques

Construction types can be classified along a spectrum between monolithic and layered building elements, with hybrid construction types in between (Table 4). In the first case, the envelope or certain parts of it, for example, the walls, consist of one homogeneous material, at least on the macroscopic level. Common monolithic building materials are concrete, bricks, or solid wood. Usually, this monolithic structure accomplishes the two functions of structure and control at the same time and sometimes also the third function of aesthetics (e.g., fair-faced concrete, brick façade, or log house). In the complementary approach, the functionally layered construction, the structural and the control functions are realized as different layers, e.g., a concrete wall with a layer of insulation material on it and a separate air tightness membrane, as well as finishing layers on both sides. Between these two approaches, timber, steel, and concrete frame constructions are often hybrid constructions in which the building is neither layered nor monolithic. Here separate parts of the envelope take over structural and control functions, respectively, e.g., part of the wall is constituted of the load-bearing structure (e.g., a concrete column) and part is made of a wall material (e.g., curtain wall, bricks, concrete blocks, and a drywall). In some special cases of framing construction, though, the envelope is layered, namely, when the column is not integrated into the envelope but is further inside the building.

Table 4. Different classical and contemporary construction styles.

CLT: cross-laminated timber.

Control functions and materials

Let us now elaborate on the earlier introduced control functions of the building envelope in more detail in terms of the building elements and materials used. The transfer of heat is controlled either by the monolithic envelope or by a dedicated insulation material. Thermal transmission losses are determined not only by the insulation, i.e., the U-value of the construction, but also by how well the design avoids thermal bridges. This is especially important when superinsulating materials used as the insulation thicknesses are smaller and hence thermal bridges have the potential to be more severe because of the shorter path lengths. Depending on climate conditions and optimization parameters (e.g., economical, ecological, energy or sustainability), different insulation thicknesses are optimal to reduce heating and cooling loads and the building operation cost. Reference Wohlgemuth, von Gunten, Manz, Zeyer and Althaus44Reference Al-Homoud46 A comparison of conventional and superinsulation materials is given in the Conventional versus Superinsulation Materials section. Unlike opaque building elements, windows control both the flow of heat and of daylight, with the technology for switchable glazing emerging that limits light and/or energy transfer (see Window Technology and Solar Transmittance Control section). Furthermore, in both cold and hot climates, the flow of air through the building envelope should be minimized as cracks and leaks usually lead to unwanted heat losses or gains. Reference Sadineni, Madala and Boehm47 Also, condensation and related damages can occur when warm air impinges on a cold part of a building element. Hence, airtightness is usually included in modern building standards and norms and is implemented technically in the form of different air and vapor barrier systems. Reference Fennell and Haehnel48 Particularly in well-insulated airtight buildings, controlled ventilation systems are installed to allow for heat recovery from the expelled air to reduce the heating demand in cold climates Reference Dodoo, Gustavsson and Sathre49 and to increase the indoor air quality (IAQ). Depending on the climate and construction, e.g., roof overhang, the envelope also should be more or less waterproof, especially the roof. This is achieved by means of special coatings, renders, bituminous waterproofing, or ventilated façades or roofs of different materials (wood, ceramic, metal, rubber, etc.). Often times, façade and roof systems are not completely waterproof but are designed with a ventilation layer that allows for drying of the building materials after exposure to rain. Furthermore, the fire behavior of the different envelope materials is of crucial importance for safety in case of a fire. A discussion of the fire properties of the structural materials, which mostly fall into the category of nonflammable materials, is beyond the scope of this article. Many insulation materials on the other hand are flammable (Table 5) because they contain combustible organic compounds. Reference Jelle50 In case of a fire, two main factors need to be considered: they contribute to the combustion load and thus accelerate the fire event and often produce toxic gases during burning, Reference Stec and Hull51 which is the main cause of fire-related deaths. Finally, regarding the function of controlling who or what can enter a building, with most of today’s construction techniques, it is possible to design an envelope that offers relative safety against intrusion.

Table 5. Comparison of conventional and superinsulation materials.

*Loss of hydrophobicity above ∼300 °C.

**Estimated bulk retail pricing (2016).

Further envelope elements

Apart from conventional opaque building elements and windows, there are a number of envelope elements that passively influence indoor comfort and save energy doing so. A good overview is given in Sadineni et al., Reference Sadineni, Madala and Boehm47 describing passive solar walls, cavity walls, latent heat storage via phase change materials (PCM), ventilated roofs, cool roofs, green roofs, evaporative roof cooling, and photovoltaic roofs and façades. Passive solar or so-called Trombe walls consist of a massive South-facing wall with a glass pane in front to create a greenhouse effect and thus transfer heat into the building. In cavity walls on the other hand, the stack effect creates a vertical air flow, passively cooling the inner wall. PCMs have a high heat storage capacity and can be used for both passive cooling and heating applications, Reference Tyagi and Buddhi52 for example, in combination with a Trombe wall. Ventilated roofs have a cooling effect similar to cavity walls, reducing heat gains in warm seasons. Cool roofs serve the reduction of heat gains as well by using materials with high solar reflectance and high thermal emittance as a finishing layer to limit the amount of energy absorbed on the roof and maximize heat emissions. Reference Zinzi and Agnoli53 An alternative approach is a roof covered with plants, making use of the insulation effect of the soil-plant layer, the shading of the foliage as well as the evapo-transpiration of the leaves. Both mechanisms have been demonstrated to have a significant effect on estival heat gains. Reference Zinzi and Agnoli53Reference Santamouris55 Green roofs have the added benefit of reducing water runoff from roofs as well as providing some thermal insulation in previously uninsulated roofs. Reference Fioretti, Palla, Lanza and Principi56,Reference Castleton, Stovin, Beck and Davison57 This approach has also been successfully applied in façades, where similar cooling effects can be achieved. Reference Sheweka and Mohamed58,Reference Pérez, Rincón, Vila, González and Cabeza59 In tropical regions, a roof pond with removable insulation or wetted burlap bag covers can be used to reduce daily solar gains. Reference Sadineni, Madala and Boehm47

Thermal comfort

Besides shelter from precipitation, wind, and solar irradiation, thermal comfort is certainly one of the main reasons why humans have been creating buildings to live and work in. Since the seminal work by Fanger in the 1960s, Reference Van Hoof41 thermal comfort models have been developed and used to quantify the satisfaction the building occupants with the interior environment conditions. These models are not only used to set the relevant building envelope parameters, such as insulation, acceptable window sizes, draft, etc., in the design phase of a building, but also operational parameters of building HVAC systems during operation to achieve a high thermal comfort inside. Hence, thermal comfort models are fundamental for building design as well as energy consumption.

There are two different basic approaches to thermal comfort in buildings: the rational or heat balance and the adaptive approach, respectively. Reference Djongyang, Tchinda and Njomo60 The former is based on experiments on human comfort in climate chambers in a steady state, most prominently represented by the work of Povl Ole Fanger. It employs a seven-point thermal sensation scale to determine the “Predicted Mean Vote” index, and from that the “Predicted Percentage Dissatisfied” is calculated—i.e., how many people will be dissatisfied under a given condition, including activity level, clothing, temperature, air speed, and relative humidity. This approach is suitable for steady-state conditions and humans in near sedentary activity levels. It works well in air-conditioned spaces, but not in naturally ventilated ones. Reference Yang, Yan and Lam61 Furthermore, the PMV seems to overestimate the thermal sensation in the tropics. Reference Kwong, Adam and Sahari62 The latter (adaptive approach) on the other hand is based on field studies on people in buildings and includes changes of activity level and clothing of building occupants in response to changes in the indoor environment. Reference Yang, Yan and Lam61 Recent research in the field has focused on thermal comfort in these transient conditions, identifying a high-energy saving potential as thermal comfort zones can be set less, restrictively. Adaptive approaches are also more suitable in tropical climates, where the PMV approach can lead to overcooling. Kwong et al. Reference Kwong, Adam and Sahari62 estimated that a 2 K rise in the thermostat set point in Malaysia would lead to 2150 GW h of annual savings. A recent review of adaptive models can be found in Ref. Reference Cheng, Niu and Gao63.

Yang and co-workers reported that adaptive thermal comfort models—which, especially for naturally ventilated buildings, describe comfort better than heat balance models—have a wider range of comfort temperature and could hence save a considerable amount of energy. Reference Yang, Yan and Lam61 Holopainen et al. studied three particular adaptive thermal comfort models, the adaptive predicted mean vote, a human thermal model, and the adaptive control algorithm, finding that all of these allowed for more flexible indoor conditions and hence lower energy use compared to heat balance models. Reference Holopainen, Tuomaala, Hernandez, Häkkinen, Piira and Piippo64

Indoor air quality

A central aspect controlled by the building envelope that is not included in thermal comfort models is IAQ. Today it still seems to hold a secondary role to energy efficiency, but it is crucial to health, comfort, and productivity of building occupants. Overall, considerations of IAQ are not only relevant in countries with high technological standards but even more so in developing countries with more traditional construction and building operation approaches. In developing regions, indoor unvented burning of biomass leads to severe health effects and is still the fourth most important disease risk factor globally. Reference Lim, Vos, Flaxman, Danaei, Shibuya, Adair-Rohani, Amann, Anderson, Andrews, Aryee, Atkinson, Bacchus, Bahalim, Balakrishnan, Balmes, Barker-Collo, Baxter, Bell, Blore, Blyth, Bonner, Borges, Bourne, Boussinesq, Brauer, Brooks, Bruce, Brunekreef, Bryan-Hancock, Bucello, Buchbinder, Bull, Burnett, Byers, Calabria, Carapetis, Carnahan, Chafe, Charlson, Chen, Chen, Cheng, Child, Cohen, Colson, Cowie, Darby, Darling, Davis, Degenhardt, Dentener, Jarlais, Devries, Dherani, Ding, Dorsey, Driscoll, Edmond, Ali, Engell, Erwin, Fahimi, Falder, Farzadfar, Ferrari, Finucane, Flaxman, Fowkes, Freedman, Freeman, Gakidou, Ghosh, Giovannucci, Gmel, Graham, Grainger, Grant, Gunnell, Gutierrez, Hall, Hoek, Hogan, Hosgood, Hoy, Hu, Hubbell, Hutchings, Ibeanusi, Jacklyn, Jasrasaria, Jonas, Kan, Kanis, Kassebaum, Kawakami, Khang, Khatibzadeh, Khoo, Kok, Laden, Lalloo, Lan, Lathlean, Leasher, Leigh, Li, Lin, Lipshultz, London, Lozano, Lu, Mak, Malekzadeh, Mallinger, Marcenes, March, Marks, Martin, McGale, McGrath, Mehta, Mensah, Merriman, Micha, Michaud, Mishra, Mohd Hanafiah, Mokdad, Morawska, Mozaffarian, Murphy, Naghavi, Neal, Nelson, Nolla, Norman, Olives, Omer, Orchard, Osborne, Ostro, Page, Pandey, Parry, Passmore, Patra, Pearce, Pelizzari, Petzold, Phillips, Pope, Pope, Powles, Rao, Razavi, Rehfuess, Rehm, Ritz, Rivara, Roberts, Robinson, Rodriguez-Portales, Romieu, Room, Rosenfeld, Roy, Rushton, Salomon, Sampson, Sanchez-Riera, Sanman, Sapkota, Seedat, Shi, Shield, Shivakoti, Singh, Sleet, Smith, Smith, Stapelberg, Steenland, Stöckl, Stovner, Straif, Straney, Thurston, Tran, Van Dingenen, van Donkelaar, Veerman, Vijayakumar, Weintraub, Weissman, White, Whiteford, Wiersma, Wilkinson, Williams, Williams, Wilson, Woolf, Yip, Zielinski, Lopez, Murray, Ezzati, AlMazroa and Memish65 In developed countries, on the other hand, while radon and tobacco smoke are linked to cancer, adverse effects of volatile organic compounds (VOCs), particles, allergens, and agents of microbial origin on human health are not well understood in terms of their mechanisms. Reference Sundell66 Nevertheless, there is a high prevalence of allergies and sick building syndrome (SBS) in regions with modern, air-tight buildings. SBS denominates the acute negative effects on health and comfort connected to staying in a given building. There is strong evidence linking indoor IAQ to lung cancer, allergies, and hypersensitivity reactions. Reference Sundell66 Additionally, perceived low IAQ is associated with SBS Reference Runeson-Broberg and Norbäck67 even when controlled for other psychological factors. While it is not clear yet how VOCs, particles, and microbial matter influence health, an interventional study recently found that a reduction in particulate matter resulted in improved respiratory health. Reference Peng, Butz, Hackstadt, Williams, Diette, Breysse and Matsui68 Also, ventilation rates have a significant influence on inhabitants’ health. In their review, Sundell et al. Reference Sundell, Levin, Nazaroff, Cain, Fisk, Grimsrud, Gyntelberg, Li, Persily, Pickering, Samet, Spengler, Taylor and Weschler69 found that higher ventilation rates of up to 25 L/s per person lead to decreased inflammation, respiratory infections, asthma symptoms, and short-term sick leave. This ventilation rate is higher, though, than the required minimum of many building standards. Furthermore, dampness in buildings, increases the risk of adverse effects on the respiratory system, such as cough, wheeze, or asthma. Reference Bornehag, Blomquist, Gyntelberg, Järvholm, Malmberg, Nordvall, Nielsen, Pershagen and Sundell70

Due to the insufficient IAQ not only health is affected but also comfort and work performance. In their review, Wargocki and co-workers Reference Wargocki, Sundell, Bischof, Brundrett, Fanger, Gyntelberg, Hanssen, Harrison, Pickering, Seppänen and Wouters71 found a strong association between ventilation, comfort, and productivity in office work environments. Maddalena et al. Reference Maddalena, Mendell, Eliseeva, Chan, Sullivan, Russell, Satish and Fisk72 reported that for short exposures of four hours, perceived air quality and SBS symptoms were unaffected by ventilation rates, but reductions in ventilation rates had a significant negative effect on decision making abilities. Park and Yoon Reference Park and Yoon73 demonstrated a logarithmic increase in addition, text-typing, and memorization tasks when increasing ventilation rates from 5 to 10 and 20 L/s per person for an eight hour observation period. In a review on studies on “average handling time” in call centers, a similar logarithmic association between ventilation rates and performance was revealed, Reference Seppänen, Fisk and Lei74 leveling off at around 45 L/s per person. Even a fifth grade student’s academic achievement could be correlated to ventilation rates. Reference Haverinen-Shaughnessy, Moschandreas and Shaughnessy75 In conclusion, proper ventilation of buildings is of crucial importance. Not only energy savings but also comfort, performance, and health needs are to be considered when designing ventilation systems and settings. Smart and demand-controlled strategies, e.g., via CO2-levels, seem to offer better solutions, as these can be more energy efficient allowing for high ventilation rates and thus high IAQ when it is actually needed. Reference Lu, Lü and Viljanen76

Conventional versus superinsulation materials

With increasing demands on thermal barrier properties of modern building envelopes, thicker insulation layers are needed. In some northern European countries, this has precipitated the use of up to 50 cm thick insulation which in some rare cases leads to wall strengths approximating 1 m, closely reminiscent of a castle wall. Clearly this is no architect’s dream. This is why we need insulating materials that offer superior thermal performance, i.e., superinsulation materials with a thermal conductivity <0.020 W/(m K). Reference Koebel, Rigacci and Achard77 Note that there exists an old definition of superinsulation corresponding to thick, conventional insulation (resulting in a low total U-value and high R-value), but in this article, we shall adhere to the modern, thermal conductivity-based definition.

Historical evolution of insulation materials

Over the last few decades, thermal insulation and hence insulation materials have gained critical importance for sustainable, energy-efficient buildings. Bozsaky Reference Bozsaky35 reviewed the historical development of insulation materials and distinguished five time periods: (i) nomadic lifestyle and temporary buildings (before 7000 B.C.) where the same insulation materials were used for buildings as for clothing (animal skins, fur, and wool), (ii) preindustrial (7000 B.C. to 1870 A.D.) with durable materials (earth, wood, and bricks) or plant fibers (straw, eelgrass, and reed) as insulation materials, (iii) industrial (1870–1950) with natural insulation products (cellulose, boards from reed, cork, wood wool, and flax), advancement of bricks (ash-filled, hollow) and artificial mineral materials (asbestos, rock wool, fiber-glass, foam glass, dross, expanded clay, and perlite), (iv) plastics (1950–2000) with a variety of plastic foams (polystyrene, polyurethane, polyester, polyethylene, phenolic, and melamine based), and (v) sustainability and low-emission (since 2000) with a revival of natural materials like cellulose, cork, etc. and exploration of new high-performance materials such as vacuum panels or aerogel materials. Thus, today, building professionals have a wide selection of insulation materials at hand, with different properties and environmental impacts, allowing for the construction of highly insulated new buildings and the renovation of existing ones in a flexible fashion.

Conventional insulation materials

An overview of insulating materials and products is given in Table 5. Conventional materials feature thermal conductivities between 0.03 and 0.04 W/(m K) with the exception of polyisocyanate foams (PU, PIR and PUR), which achieve lower thermal conductivities through the use of a heavy, low thermal conductivity filler gas inside the closed-cell network, e.g., a mixture of CO2 and iso- or cyclopentane. Next to these standard products, there exists a variety of insulation materials derived from natural products, e.g., straw, reed, eelgrass, cellulose fiber-based materials, animal furs, sheep wool etc., or inorganic materials, e.g., foam glass, foamed clay, pumice etc. These materials are attractive from an embodied energy perspective but suffer from significantly higher thermal conductivities. Modern construction in first and second world countries nowadays are insulated primarily with polymer foams and glass or mineral wool (>90% market share). 78 These products are durable, low-cost commodities with the best price per performance ratio. Polymer foams (EPS, PU/PIR/PUR) are intrinsically flammable which negatively affects fire ratings, and environmental concerns have been raised for classes of flame-retardant additives. Reference Hale, La Guardia, Harvey and Mainor79 Other insulation strategies do not use a separate material for insulation but modify the properties of the load-bearing envelope materials, for example, the addition of cenospheres to concrete to decrease weight and thermal conductivity. Reference Blanco, García, Mateos and Ayala80

Superinsulation materials and products

The class of superinsulators consists primarily of fumed silica, aerogel-based materials, and vacuum insulation panels (VIP). More recently, people have also started to investigate gas-filled panels as a possible building insulation solution; however, no superinsulating products of this type are yet available commercially, partly due to the high cost of ultralow thermal conductivity filler gases such as krypton. Reference Baetens, Jelle, Gustavsen and Grynning81 VIP and aerogel-based superinsulating materials and solutions have been on the market for roughly 10–15 years. These products offer superior performance (very low thermal conductivity) but are more expensive than conventional insulation to reach the same insulation performance (U-value). Fumed silica, aerogel, and VIP are known and established niche products in the building and construction industry, but their market share is below 1% of the total market. Reference Koebel, Rigacci and Achard77 In Europe, aerogel insulation sales for building applications are estimated to lie within the 25–30M US$ range for 2016. For the same year, the global aerogel market is roughly 250M US$, which is on the order of 0.5% of global insulation markets which are estimated at 45B US$. 78 Vacuum insulation markets are of a similar magnitude with 2014 sales on the order of 380M US$ 82 of which roughly 15% of it are used in the building and construction sector. Both aerogel and VIP markets are growing rapidly at a CAGR of approximately 20%.

Superinsulation materials come in many forms: VIPs, monolithic aerogels, silica aerogel granulate, blankets, boards, and paste-like wet mix formulations such as insulating renders (Fig. 1). Most of the development on VIPs is on less expensive core materials, Reference Kwon, Jang, Jung and Song83 where the main challenge is to match thermal and service life performance of traditional fumed silica cores [Fig. 1(a)]. Reference Simmler and Brunner84 Monolithic aerogels are not yet commercially available due to high production cost, although BASF is in the process of scaling up Slentite, which may well be the first commercial polyisocyanate aerogel insulation product [Fig. 1(b)]. Aerogel granulate and blankets are today’s most viable industrial materials. Cabot aerogel is manufacturing hydrophobic, silica aerogel granulates [Fig. 1(c)], and the aerogel market leader Aspen aerogels produces blanket-type products such as Spaceloft [Fig. 1(d)]. Both product types are rarely used as-is on the construction site but are typically converted into a (semi-)finished product or solution which will then be applied or installed at the building site. Two examples of such aerogel-based products are aerogel insulation boards, e.g., Heck Aero obtained by gluing several Spaceloft blankets together, or a wet applied high-performance render which was especially developed for retrofitting old historical buildings. Reference Stahl, Brunner, Zimmermann and Koebel85 Aerogel renders are insulating render systems which contain a large volume fraction of aerogel granulates as a low thermal conductivity filler. They are sold in bags as a dry mix formulation containing mineral binders and additives, allowing facile on-site mixing with water and direct application on the façade using conventional render projection pumps. Other granulate-based composite materials such as aerogel concrete Reference Fickler, Milow, Ratke, Schnellenbach-Held and Welsch86 or glued composites are also under development.

Figure 1. (a) Cross section of a vacuum insulation panel, (b) monolithic aerogel board (courtesy of BASF), (c) silica aerogel granulate, (d) silica aerogel blanket, (e) silica aerogel board, and (f) silica aerogel render.

The use of superinsulating materials today is still very restricted in the B&C sector due to the high price, low innovation dynamics of the sector, and large number of stakeholders involved in the construction process. However it is clear that urbanization and energy policy are huge drivers for the commercialization of superinsulation materials and solutions on a broader front. To accomplish this, improved production methods combined with the economy of scale must bring down prices, innovative products which combine all advantages of superinsulation must facilitate installation and market entry, and communication efforts must educate and inform stakeholders about these new possibilities.

Window technology and solar transmittance control

Windows visually connect the building interior to the outside world and provide a functional and pleasant indoor environment. The effect of windows on the energy performance of the façade is complex: the thermal transmittance of windows, i.e., the U-values, are typically two to five times higher than for other façade elements, but the resulting heat losses are typically more than offset by solar gains, expressed by the g-value or Solar Heat Gain Coefficient of a given glazing unit. Reference Rezaei, Shannigrahi and Ramakrishna87

Heat losses (U-value)

The last six decades have seen a five to ten-fold reduction in the U-values of glazing solutions through a variety of technological cornerstone developments. The introduction of double glazing in the 1950s lead to nearly a two-fold reduction of the center of glazing U g-value from >5 to approximately 3 W/(m2 K) and marks the start of insulation glazing as a research field. Over the next forty years, the industry again made tremendous progress by introducing low-emissivity (low-E) coatings and argon as a filler gas as well as the introduction of triple glazing. The introduction of low-emissivity (low-E) coatings, which are now standard in modern insulated glazing, led to the most dramatic improvement of the glazing’s thermal properties, allowing a reduction of the radiative thermal conductance due to radiation from approximately 1.5 down to 0.1 W/(m2 K). Reference Manz88,Reference Jelle, Kalnæs and Gao89 The use of mono-atomic filler gasses with lower thermal conductivity also leads to a significant reduction in the U g-value: replacing air by argon results in a reduction of approximately 0.5 W/(m2 K), and the use of krypton or xenon can further reduce this by an additional 0.2–0.3 W/(m2 K), respectively. Reference Manz88 Based on cost and availability, argon is by far the preferred filler gas, whereas krypton is limited to high-end products only. As the center of glazing U g-values improved due to the use of low-E coatings and low-conductivity filler gases, heat losses through the edge have gained relative importance. Significant improvements have been achieved by optimizing spacer materials and design: replacing aluminum spacers for stainless steel, foam, and thermoplastic spacers and optimizing the spacer geometry results in a significant reduction of these edge effects. Reference Van Den Bergh, Hart, Jelle and Gustavsen90,Reference Jelle, Hynd, Gustavsen, Arasteh, Goudey and Hart91 Further improvements have come from optimizing the design and materials of the sash-and-frame construction in terms of thermal conductivity. Reference Gustavsen, Grynning, Arasteh, Jelle and Goudey92 Note that the degree to which the various technologies have been adopted varies wildly depending on region, country, building norms, purchasing power, climate, and environmental awareness. Europe is leading the way with respect to market uptake: advanced insulated glazing with argon filling, high-performance low-E coatings, and optimized spacer and sash-and-frame designs with U w-values for the entire window around ∼1.1 and ∼0.6 W/(m2 K) for double and triple glazing, respectively, are now the standard solution.

In addition to the above-described mainstream developments, even higher performant glazing elements are available for niche markets. The addition of a fourth layer of glazing further lowers the U-value, but such products have not made an impact in the market due to the high cost-to-benefit ratio, high weight, and increased thickness. Reference Thalfeldt, Pikas, Kurnitski and Voll93 More innovative solutions along this line are the use of thin glazing layers in quadruple glazing or polymer film multi-chamber glazing units. Reference Hood, Vincent and Booth94 Vacuum insulation glazing (VIG) approaches the problem differently and eliminates the gas phase conductance altogether but requires stringent criteria on the edge seal and the use of support pillars to keep the panes apart, resisting against the outside atmospheric pressure. Reference Collins and Simko95Reference Cuce and Cuce97 In theory, U-values down to 0.3 W/(m2 K) can be achieved with a single VIG. Vacuum glazing products have been on the market for several decades now, but in general, their performance is poor [between 0.5 and 1.1 W/(m2 K)] when measured against theoretical limitations, barely keeping up with state-of-the-art triple glazing in terms of U-value. Their commercial success will eventually rely on the thin design, although recent developments by new Chinese manufacturers Reference Simko and Collins96 claim products with U-values <0.6 W/(m2 K). It is the slim design (<10 mm) which enables retrofitting of existing frames in historical buildings by directly replacing single-paned glass by VIG, providing excellent thermal and sound insulation properties, which is highly desirable for inner-city applications. Transparent aerogel glazing can achieve U-values below 0.7 W/(m2 K) for a glazing thickness below 15 mm at the prototype level, Reference Buratti and Moretti98Reference Jensen, Schultz and Kristiansen100 but upscaling and product development using this technology are challenging at a laboratory scale and are virtually impossible at an industrial scale due to the brittleness of the aerogel. Translucent aerogel elements for daylighting applications that typically consist of a cavity filled with aerogel granulates Reference Buratti and Moretti98,Reference Reim, Körner, Manara, Korder, Arduini-Schuster, Ebert and Fricke101 have been introduced in the market, and U-values from 0.3 to 0.6 W/(m2 K) can be achieved depending on thickness, with an optical transmittance of 45–60%.

Solar gains and solar control (g-value)

Due to their transparent nature, windows’ high heat losses are offset, by solar gains and windows with a high g-value, i.e., with a high solar energy transmittance, can strongly decrease the heating demand. However, solar gain control is required to provide glare protection and avoid overheating during warm and hot periods, even though the energy reflected back to the environment may increase the heat island effect. Passive solar control measures include the use anti-reflective (low-emissivity) coatings Reference Raut, Ganesh, Nair and Ramakrishna102 and angular selective window systems that differentially reflect the sunlight depending on the incidence angle. Reference Fernandes, Lee, McNeil, Jonsson, Nouidui, Pang and Hoffmann103,Reference Gong, Kostro, Motamed and Schueler104 The traditional and most straightforward way to actively control solar gains is by external blinds and this is by far for the most implemented solution. However, external blinds are prone to wind or hail damage and their installation and maintenance cost can be substantial. From a materials science perspective, switchable glazing is a highly attractive form of active solar control. Reference Georg, Georg, Graf and Wittwer105 Here, the optical transmission and solar gain can be switched between a bleached and darkened state by changing the redox state of a thin active material layer. Depending on the stimulus, this can be a form of active solar control, e.g., electrochromic Reference Granqvist106 and gasochromic Reference Wittwer, Datz, Ell, Georg, Graf and Walze107 glazing or passive solar control, e.g., photochromic Reference Hauch, Georg, Baumgärtner, Krašovec and Orel108 and thermochromic Reference Parkin and Manning109 glazing. All of these are active areas of scientific research, but electrochromic glazing based on tungsten oxide, WO3, (Fig. 2) has been most successful in the market. Reference Granqvist106 Academic and industrial research actively pursues improved performance by changing from liquid based to solid state electrolytes and optimizing the electrochromic material film properties, e.g., by improving the sputter-deposition, sol–gel synthesis, Reference Livage and Ganguli110 and vapor deposition, Reference Lee, Deshpande, Parilla, Jones, To, Mahan and Dillon111 the quest for alternatives to WO3 such as VO2/V2O5 Reference Scherer, Li, Cunha, Scherman and Steiner112 or NiO, Reference Sialvi, Mortimer, Wilcox, Teridi, Varley, Wijayantha and Kirk113 the use of polymer electrolytes Reference Thakur, Ding, Ma, Lee and Lu114,Reference Marcilla, Alcaide, Sardon, Pomposo, Pozo-Gonzalo and Mecerreyes115 or the development of infrared selective devices. Reference Runnerstrom, Llordés, Lounis and Milliron116 Other proposed active solar gain control measures include the use of circulating suspensions of light absorbers, where active control is achieved by tuning the particle concentration, e.g., FluidGlass. Reference Stopper, Boeing and Gstoehl117 Active solar gain control systems can be operated manually, i.e., at the discretion of the building occupant, or automatically. Together with controlled ventilation, automated solar gain control is one of the key components that allows the building energy management system to dynamically respond to the user demands and weather conditions (see also “Dynamic Behavior, Building Energy Management and Smart Grids” Section).

Figure 2. Schematic cross section of WO3 based electrochromic glazing. The coloration of the electrochromic layer can be tuned by switching the redox state of the active electrochromic material layer, most typically WO3. The current is provided through a transparent conductive oxide layer (TCO). The device design is an electrochemical cell similar to a battery.

Lighting

Incandescent lighting has had a tremendous impact on the society, so much so that the image of a light bulb has become synonymous with a good idea, and Thomas Edison has become the archetypal inventor in popular culture. Indeed, incandescent lighting has been the standard technology for nearly the entire 20th century. Standard incandescent light sources have a luminous efficacy of approximately 15 lm/W. Halogen incandescent bulbs have been available since the 1950s and have now an efficacy on the order of 30 lm/W. Fluorescent lights (TL) have a much higher efficiency on the order of 25–95 lm/W. Commercially available light emitting diodes (LEDs) already achieve a higher efficacy than that of the fluorescent tubes (up to 130 lm/W) with a theoretical limit of 260–300 lm/W. Reference Pimputkar, Speck, DenBaars and Nakamura118,Reference Krames, Shchekin, Mueller-Mach, Mueller, Zhou, Harbers and Craford119 The rate of progress in this field is remarkable not only with respect to the development of more efficient LEDs but also with respect to their adoption in the market place. Their low efficacy has finally caught up with incandescent lighting, and incandescent light bulbs have even been banned for most uses by the European Union. The energy consumption due to lighting has decreased substantially over the last two decades, with, for example, a drop from 38 to 17% in the share of lighting to the overall electricity consumption of commercial buildings. 120 These savings are not only related to the above-described efficiency increase of the light sources but also to the reduced wastage, for example, by automatically switching of the lights when a space is not occupied and a better use of natural daylight through better architectural planning. Research on improved light sources, buildings and illumination automation, and architectural solutions to daylighting is ongoing, but the advances made over the last decades have already reduced the impact of lighting on the overall energy budget of buildings.

Renewable energy

Once the building envelope is brought up to a certain thermal standard, it is easier to cover the remaining energy demand from renewable sources. To become fit for the future, buildings must produce a significant fraction of their demand themselves. Solar energy is by far the most common renewable energy source for buildings through the use of solar thermal collectors, photovoltaics, and hybrid Reference Kumar and Rosen121 elements, where the market share of the latter remains comparatively small.

Solar thermal collectors

Solar thermal collector technology is a rather mature field, and solutions with various degrees of technical complexity are on the market. Reference Tian and Zhao122 Selective absorbers increase the operating temperature by having a high ratio of solar radiation absorption to thermal radiation emission. Reference Kennedy123 Building integrated modules are typically nonconcentrating collectors, with the same intercepting area as its absorbing area. Concentrating collectors, which focus the solar irradiation of a large intercepting area onto a small absorbing area using concave mirrors, can achieve much higher fluid temperatures and Carnot efficiencies but are much less common in buildings. Among the nonconcentrating collectors, flat-plate collectors, which exist for over a hundred years, are most commonly used. They consist of an absorber (e.g., a painted copper plate) which is welded to a copper pipe that acts as the heat transport vehicle. The absorber is then enclosed inside an insulated metal trough which is in turn covered by a cover glass. Evacuated tube collectors are a more recent development with first products appearing on the market after the first oil crisis in the seventies. A typical device uses a central copper pipe with absorber fins which is welded into an evacuated glass tube. The glass tube itself is typically a double-walled vessel which is also evacuated and sealed, resulting in minimized heat losses through gas conduction, the same principle which VIPs and vacuum glazing are based on. As a result of the lower heat losses, a higher working fluid temperature can be achieved. In addition, the specific geometry results in the exposure of the absorber to the sunlight for a longer period of the day. Reference Zambolin and Del Col124 Flat-plate collectors are the solution of choice for a majority of climates and user profiles as they are roughly 30–40% cheaper than tube collectors for the same installed power. Vacuum tube collectors make sense in very cold climates, although they are slow to shed a possible snow cover and for applications where a higher medium temperature is required. Very often, solar thermal collectors are combined with heat pumps and/or underground thermal energy storage systems. Reference Sanner, Karytsas, Mendrinos and Rybach125,Reference Trillat-Berdal, Souyri and Fraisse126

Building integrated photovoltaics (BIPV)

The development of new solar cell materials is a very active area of research and is out of the scope of this review. Record efficiencies for single-junction, single-crystal and multicrystalline silicon are currently around 25 and 21%, respectively, Reference Green, Emery, Hishikawa, Warta and Dunlop127 and silicon is by far the most widely used material. The performance, in terms of efficiency, of thin film cells (GaAs, CdTe, CIGS), multijunction devices (InGaP/GaAs/InGaAs) can be higher than that of silicon, but at the moment, none of these materials have made an impact in the building and construction sector. Following a continuous and dramatic reduction in cost (Moore’s law behavior), silicon solar panels have become a commodity and installation, rather than materials, now make up the vast majority of the total cost. Historically, solar panels have been added on top of an existing building envelope almost as an afterthought. In contrast to these building-adopted photovoltaics, building-integrated photovoltaics are an integral part of the building envelope, offering weather protection as well as aesthetic function. Reference Omer, Wilson and Riffat128,Reference Yang, Zheng, Lou, An and Burnett129 This double function as an energy producer and the building skin makes BIPV more cost effective because other cladding materials are no longer needed Reference Heinstein, Ballif and Perret-Aebi130Reference Shukla, Sudhakar and Baredar132 and new possibilities for the aesthetics of photovoltaics have been developed. Reference Heinstein, Ballif and Perret-Aebi130 The vast majority of photovoltaics are installed on the roof, but various solutions for the façade are available. In the summer, the amount of solar irradiation reaching the façade is lower than that of the roofs, as expected, but due to the large areas concerned, facades can contribute significantly to the solar potential of buildings, depending on climate, building geometry, and orientation. Reference Redweik, Catita and Brito133 In the winter, on the other hand, façade BIPVs can have higher output than that of PV on the roof due to the lower position of the sun. The emergence of printable PV technologies opens up renewed opportunities for building integration. Reference Tsoutsos, Farmaki and Mandalaki134

Thermal storage and sorption cooling

Thermal storage

The ability to store energy in various forms for delayed or distributed use is a topic of increasing actuality. The key parameters defining energy storage systems are the storage time period, capacity, and cost. To cover the daily fluctuations in thermal energy demand (hot water), a storage period of a few days and a relatively small capacity are sufficient. The most straightforward way to store thermal energy is in the form of sensible heat, i.e., by capitalizing on the heat capacity of a given storage medium. Hot water reservoirs or boilers are the classical example for this type of simple solution. Long-term seasonal storage of thermal energy for low-temperature (e.g., floor heating) systems is relatively costly and requires large water storage volumes when operated exclusively on a sensible heat principle. For well-insulated low-energy buildings [U wall < 0.15 W/(m2 K), triple glazing], the heating demand during the winter season in central Europe can be covered with a typical water reservoir on the order of 20–50 m3. Around the turn of the millennium, several experimental large thermal storages have been realized and tested with solar thermal collector areas up to 5000 m2 and water storage reservoirs up to 12,000 m3 in size. Reference Lottner and Mangold135 A more recent trend is to use the ground as a thermal energy store and deposit excess thermal energy into geothermal boreholes either directly or, preferably, through a conventional heat pump system. Reference Stene136,Reference Hellström137

Latent heat storage uses the enthalpy of fusion or evaporation of a storage medium and is a promising alternative to sensible heat storage, especially if the space is limited. It offers a 2–5 times higher volumetric energy storage density (Table 6) and furthermore delivers the thermal energy at a constant temperature level, i.e., at the specific phase transition temperature of the storage medium, rather than at progressively lower temperatures such as in the case of a sensible heat storage system. Both liquid and solid latent heat storage materials and systems are known. Latent, seasonal heat storage devices could offer significant potential to reduce the heating demand in colder climates with reduced space demand. Pure latent heat storage devices work at a constant composition/mass, the typical example being phase change material (PCM) storage. Reference Zalba, Marín, Cabeza and Mehling138

Table 6. Overview of common heat storage materials. Reference Zalba, Marín, Cabeza and Mehling138,Reference Kaufmann and Winnefeld139

Alternatively, thermochemical storage involves the storage and release of thermal energy in a chemical form, e.g., salt hydration or water sorption which means a sorbent or “reagent” is added thus changing the mass and composition. Such systems have received increasing attention for their potential use as space-saving, seasonal heat storage solutions. For example, a novel promising system currently under development at our institute (Empa) is a high ettringite CSA solid cement system which uses hydration/dehydration of ettringite type phases that offers up to 500 MJ/m3 storage capacity in a temperature range between 40 and 120 °C with material cost comparable to other types of high-performance concrete. Reference Kaufmann and Winnefeld139 Other types of more classical solid thermochemical energy storage systems (zeolites, silica gels, hybrid zeolite/salt systems) have also been studied for seasonal heat storage Reference Dicaire and Tezel140,Reference Hongois, Kuznik, Stevens and Roux141 with storage energy densities similar to that of the ettringite but at a higher materials cost. Even higher storage densities are possible when a dilution or sorption process is combined with the condensation of the sorbate. When using an aqueous system, for example, one can then capitalize on the latent heat of water evaporation/condensation by operating in a partial vacuum. One of the more promising systems in this category uses a concentrated sodium hydroxide solution, Reference Fumey, Weber, Gantenbein, Daguenet-Frick, Williamson and Dorer142 which stores its energy in the form of potential dilution and latent heat of water vapor condensation (added later during the discharging cycle). This latter system offers a very high theoretical storage density up to 1350 MJ/m3. Reference Mette, Kerskes and Drück143

By far, the most common use of latent heat storage materials at the single building level is the incorporation of PCMs into the building envelope. Selected application examples have been discussed in the building envelope section. In this way, thermal energy can be stored during the daytime (solar gains) and released during the night thus reducing the heating demand during wintertime. Typically the active temperature window of a PCM material is rather narrow and must be adapted to a specific building/use case scenario since it corresponds to a phase transition (melting/solidification) with a well-defined temperature level. Generally, two types of compounds are used as the active material, namely salt hydrates (potassium fluoride, calcium chloride) and “wax-like” long chain fatty acids and hydrocarbons (butyl stearate, octadecane, propyl palmitate etc.). Mixtures are often used to adjust the melting point to the specific application needs. Typical heats of fusion of PCMs are in the 150–200 kJ/kg range. Reference Khudhair and Farid144 Note that the organic, hydrocarbon-based PCMs are highly flammable which may render building integration challenging. Much of today’s research & demonstration activities are centered on encapsulation, packaging, and integration into building components and architectural elements. The development and testing of PCMs for building applications have been a topic of great research activity in the past twenty years, Reference Khudhair and Farid144Reference Jamekhorshid, Sadrameli and Farid146 but the market uptake in the built environment is still rather hesitant.

Heating systems

Despite advances in envelope performance, including the optimized use of solar gains (see above), most buildings in cold and temperate climates require active heating during winter and hot water supply around the year. For highly-insulated buildings, the energy needed to provide hot water can even become the dominant part of the overall yearly energy demand. The most common heat sources for buildings fall into one of the three categories of combustion, heat pumps, and solar thermal. Electric direct heating is very inefficient in terms of primary energy and hence will not be discussed in the following. Combustion heating systems for buildings are typically based on oil, gas, or coal as nonrenewable energy sources with wood as a renewable alternative. The most common heat pump systems for buildings are brine–water, air–water, and water–water systems. Brine–water systems are usually operated as ground-coupled heat pumps, i.e., heat is extracted from the ground and transferred to water used for heating. For that, brine is circulated either in vertical, u-shaped pipes in ground boreholes of depths between 50 and 300 m, where the ground temperature is more or less constant all year long or in horizontal pipe arrangements at a depth of about 1–4 m, where the ground temperature is dominated by solar irradiation and precipitation and hence varies with the seasons. Reference Florides and Kalogirou147 The second approach is usually more cost-effective but can only be used if sufficient space is available around the building and hence is not well suited in cities. In water–water heat pump systems, flowing water, often times ground water, is used as the heat source; whereas, in air–water systems, heat is extracted from the surrounding air. There are also hybrid systems, which combine, for example, a ground-coupled heat pump with an air heat pump or a solar collector system. Reference Trillat-Berdal, Souyri and Fraisse126,Reference Yang, Cui and Fang148 With ground-coupled heat pumps, depletion of the ground heat can occur after a few years, so a so-called thermal “regeneration” of the soil surrounding the borehole might become necessary. This can be achieved by circulating warm water from solar collectors in the borehole Reference Trillat-Berdal, Souyri and Fraisse126 or by using the borehole as a heat sink for building cooling. Reference Yang, Cui and Fang148 Finally, solar thermal systems can be used to provide hot water and heating. Depending on the solar irradiation in the winter, these systems can be either used as an additional heat source, in combination with a heat pump system, or as the main heat source in combination with seasonal heat storage.

The presented systems can be evaluated with respect to costs—installation and operation—environmental impact, availability, and compatibility with the planned or already available heat delivery system to find an optimized solution for a given building. An evaluation of the cost of the different systems is beyond this discussion because cost strongly depends on location, and future trends are hard to predict. With respect to environmental impact, fossil fuels are characterized by high net CO2 emissions; whereas, the CO2 impact is considerably lower for wood fuels. Reference Wang, Chang, Zhang, Pang and Hao149 Other emissions and their toxicological impact depend on the type of wood fuel and can be minimized by filtration to levels below those of oil combustion. Reference Kasurinen, Jalava, Tapanainen, Uski, Happo, Mäki-Paakkanen, Lamberg, Koponen, Nuutinen, Kortelainen, Jokiniemi and Hirvonen150,Reference Sippula, Hokkinen, Puustinen, Yli-Pirilä and Jokiniemi151 For heat pump systems, the environmental impact depends on the coefficient of performance (COP) and on how the electricity they consume is generated. If renewable sources of electricity are used, heat pumps have a low-environmental-impact. Solar heat systems generally have a very low environmental impact. Reference Zambrana-Vasquez, Aranda-Usón, Zabalza-Bribián, Jañez, Llera-Sastresa, Hernandez and Arrizabalaga152 While combustion heating systems are widely available, ground-coupled and water-coupled heat pump systems cannot be used in every location, and air–air heat pumps can be problematic due to noise emissions. The feasibility of solar thermal heating systems depends on the climatic conditions. Finally, the heat delivery system limits how efficiently the generated heat can be distributed. Radiators require high-flow temperatures (∼60 °C) and thus favor the use of combustion heating as heat pumps are not very effective for such high temperature differences. Floor or wall heating, on the other hand, can be operated at considerably lower temperatures (∼30 °C) and also heat pumps and solar thermal are effective in these cases.

Finally, it should be noted that the discussed heating systems can also be implemented on a larger scale as district heating—usually with corresponding increases in efficiency and reduction in emissions for combustion systems. Furthermore, in district heating plants, other combustion fuels can be used, and the waste heat of industrial processes can be utilized. Hence, district heating often offers a low-environmental-impact heat supply.

Sorption cooling

With increasing global temperatures and comfort needs, cooling and dehumidification demands are expected to rise roughly ten-fold by 2050 from today’s level, whereas the heating demand will plateau. Reference Forman, Muritala, Pardemann and Meyer153 At the same, a recent review estimates the global waste heat at “low”-temperature levels below 100 °C at 156,000 PJ Reference Eichholz and Schulz154 or roughly 27% of the global energy consumption. For waste heat at low temperatures, carnotization, e.g., the conversion into other energy forms using, for example, a steam turbine, is clearly inefficient and the tremendous pool of unused waste heat is contrasted by the lack of suitable use scenarios. “Thermally driven” sorption heat pumps are flexible and scalable (from kW to MW power) systems which allow facile valorization of waste heat or solar thermal energy and thus offer a unique way to make better use of untapped thermal energy sources. More specifically, sorption heat pumps can be used to convert currently worthless, low-grade heat into precious cooling power with a COP around 0.5–0.6, potentially massively contributing to reducing the global electricity consumption. In a second mode of operation, sorption heat pumps can upgrade waste heat from a higher to a lower temperature level to provide the warm water required for low-temperature floor heating in buildings with a COP around 1.5.

Sorption heat pumps with liquid sorbents such as alcohol-water, ammonia etc. have been widely studied. Reference Jernqvist, Abrahamsson and Aly155Reference Shelton157 More recently, solid sorbents have been investigated due to the significantly lower cycled thermal mass. Reference Meunier158,Reference Henninger, Schmidt and Henning159 In comparison with a conventional heat pump in which a mechanical compressor drives the cycle, adsorption heat pumps make use of adsorption/desorption cycles of a sorbate, most often water, onto a porous solid sorbent to provide a temperature lift. Current R&D is targeting primarily the development of more efficient sorbents with tailored hierarchical porosity as well as a heat exchanger design and fast/smart assembly techniques. Preferred materials Reference Dell and Rand160 have steep, step-like adsorption isotherms in the application-relevant pressure range relevant to maximize the amount of cycled adsorbate. Adsorption heat pumps are commercially available from a few suppliers worldwide, but significant improvements in their efficiency and space requirements are needed to allow a more widespread market penetration. Innovative manufacturers such as Sortech in Germany have recently developed the so-called hybrid compressor driven/sorption heat pump machines which offer added flexibility and extremely high efficiency under a partial cooling load.

In conclusion, thermal storage and adsorption cooling are not yet widely implemented, primarily due to the low energy cost, comparably high initial investment, and long payback times of such solutions. Nevertheless, technologies focusing on more efficient usage of waste heat such as seasonal storage and thermally driven heat pumps are expected to play an important role in energy networks at the district and energy hub scale as well as at the cradle, the producer of thermal waste heat, in the coming decade.

Electrical energy storage

In the previous section, we emphasized the ability of thermal technologies to reduce the electrical demands for heating and cooling. With the installation and production of renewable energy sources on the rise, temporal production-demand matching is recognized as the central challenge. Undisputedly, battery storage can increase the photovoltaic self-consumption in buildings. Reference Luthander, Widén, Nilsson and Palm161 Various types of electrical energy storage solutions exist which can be used from a single building (kW h) to district (MW h) to megacity (GW h) scale. Reference Deane, Gallachóir and McKeogh162 Energy storage solutions combined with energy district networks and smart grids are likely to see a massive increase in implementation in the coming decades. Amongst all the direct electrical energy storage systems, the most relevant ones for the built environment are those with an intermediate storage period on the order of hours to single days. In the following, we shall briefly sketch available technologies in the order of decreasing the storage capacity.

Highest capacity and low-cost, low-tech, easy to implement solutions are based on mechanical potential energy storage. Hydropower pump storage systems are typically massive installations in the 500–15,000 MW h capacity range which are used as large scale buffers for the electric grid and are not of specific relevance to the built environment. Reference Lund and Salgi163 Compressed air storage (CAES) employs underground caverns as reservoirs to deposit and release pressurized air which is then converted to mechanical/electrical energy through a compressor/turbine assembly. Reference Cheung, Carriveau and Ting164 Typical installations are of medium to high capacity in the low GW h range. Storage times of several hours to one day are typical and determined by the ratio of volume to total leakage of the cavern system. Until now, several CAES pilot projects have been realized. The overall storage efficiency depends on the type of gas expansion process, with the most advanced adiabatic concepts such as ADELE in Strassfurt aiming to achieve 70% overall storage efficiency. The Hydrostor project in Lake Ontario, Canada employs an alternative, novel, and rather elegant design with submerged air balloons acting as storage vessels for the compressed air, Reference Divya and Østergaard165 thus potentially expanding the range of applications of this technology which is currently limited by location and availability of high-quality natural storage caverns to large lakes and easily accessible offshore locations.

Batteries are the most promising medium for low to intermediate capacity buildings and district storage needs. Reference Dufo-López, Lujano-Rojas and Bernal-Agustín166 Perhaps the most widely used batteries are of lead–acid type given their wide availability, established low-tech technology, and a very low cost of around 100 $/kW h installed capacity. Newest generation “gel-type” and “flooded-type” lead acid batteries have significantly improved on both aspects but still are far from ideal for stationary high-volume storage given their need for regular maintenance (replenishing lost water) and poor service life (only a few hundred cycles). Reference Nykvist and Nilsson167 Nickel-cadmium batteries and the more advanced nickel metal hydride (NiMH) cells have significantly higher life span than lead acid batteries but are considerably more expensive. Modern cylindrical NiMH cells offer roughly twice the volumetric energy density (in the 250–300 W h/L range) compared to NiCd batteries. This high-energy density, combined with low maintenance, good storage efficiency, and long lifetime (3000 cycles at 100% depth of discharge), makes them ideal for stationary applications. The top-tier class of batteries is based on the Lithium-ion technology. It offers superior gravimetric and volumetric storage densities as well as excellent cycle stability. Various technologies exist, but cells employing inorganic oxide type solid state cathode materials, e.g., lithium iron phosphate (LiFePO4), lithium ion manganate (LiMn2O4, Li2MnO3), and lithium nickel manganese/cobalt oxide (LiNiMnCoO2), are generally more stable than, for example, lithium polymer (LiPo) cells and hence seem better suited for stationary storage. Just a few years ago, the cost of lithium ion batteries were still significantly higher at around 1000$/kW h capacity, but rapid advances and commercialization of electric vehicles (EVs) have driven prices down to the 300$/kW h range Reference Kim, Boysen, Newhouse, Spatocco, Chung, Burke, Bradwell, Jiang, Tomaszowska and Wang168 and insider analysts even cite 190$/kW h, which makes them competitive for stationary storage. A possible scenario pursued by Tesla Motors is the refurbishing of Li-ion cells from used EV battery packs for domestic storage needs, thus extending the life cycle of those batteries to be used in wall-mounted modules for domestic electrical storage.

High-temperature batteries typically use alkali metal anodes in liquid form. Common systems are sodium sulfur (Na/S) and sodium/nickel chloride (ZEBRA battery) systems. High-temperature batteries offer excellent efficiency (>85%), lifetime (2500–5000 cycles at 80% depth of discharge), and relatively low-cost components. At the system level, however, thermal and safety management are issues which render this technology less competitive. Although in principle a highly attractive stationary battery storage concept, the market prospects of Na/S, Li/S, and Zebra batteries are being challenged by the rapid capacity increase and drop in prices of lithium ion cells. A more recent adaptation of the thermal battery concept typically used in military applications is the so-called liquid-metal battery developed by AMBRI, an MIT spinoff. The concept is based on liquid metal electrodes and a molten salt electrolyte and was developed for medium-scale stationary storage applications. Reference Kear, Shah and Walsh169 Despite the somewhat lower energy density, the technology uses low-cost components and a design that can yield lifetimes >10,000 cycles, assuming that cell sealing and material durability issues can be solved.

The most recent addition to the battery family, redox flow batteries, are based on liquid anode and cathode materials which are converted in a dual flow cell type setup. Reference Wang, Luo, Li, Wei, Li and Yang170 Redox flow batteries offer not only relatively low energy densities but also the advantage of decoupled redox and conversion systems, thus also enabling long-term (seasonal) storage solutions. This decoupled design also results in outstanding cycling stability which makes it a promising solution for stationary applications.

Chemical electrical energy storage, for example, in the form of hydrogen or syngas (synthetic methane) is less relevant at the single building level but can add great long-term storage flexibility to energy district networks and is expected to find more widespread use in mobility applications. Reference Khaligh and Li171

Dynamic behaviour, building energy management and smart grids

Efficient operation of modern buildings is a challenge, particularly when implementing renewable energy production. The problem of building energy management is clearly multidimensional. Reference Dounis and Caraiscos172 A summary of the use of a full set of metaheuristic optimization methods for finding the optimal operation of energy systems including electric and thermal storage as well as a heat source is given in Ikeda and Ooka. Reference Ikeda and Ooka173 The occupants display a dynamic range of behaviors with strong temporal variations at diurnal, weekly, and seasonal length scales in terms of thermal comfort, light intensity, and air quality requirements. At the same time, buildings are only partially insulated from the weather outside. Furthermore, energy cost, supply, and demand are expected to fluctuate dramatically in a world of renewable energy. The goal is to find the right compromise between the conflicting demands of users’ comfort, energy consumption, and cost and CO2 emissions. The management system then implements the selected strategy in terms of the input and storage of renewable energy (thermal and electrical), solar gains, controlled ventilation, and the operation of household appliances. Smart homes are equipped with sensors that not only feed into the building energy management system but also improve the safety of, e.g., elderly occupants. Reference Chan, Estève, Escriba and Campo174 There is an extensive literature on optimization algorithms and strategies, such as whole building simulations, Reference Dorer and Weber175 model predictive control, Reference Široký, Oldewurtel, Cigler and Prívara176 evolutionary programming Reference Fong, Hanby and Chow177 and genetic algorithms, Reference Attia, Hamdy, O’Brien and Carlucci178 artificial neural networks, Reference Magnier and Haghighat179 and particle swarm optimization. Reference Wang, Zhai, Jing and Zhang180 Taking into account the weather prediction and its associated uncertainties further increases the comfort and lowers energy consumption. Reference Oldewurtel, Parisio, Jones, Gyalistras, Gwerder, Stauch, Lehmann and Morari181 Other building energy management systems include real-time variations in energy prices. Reference Missaoui, Joumaa, Ploix and Bacha182,Reference Tsui and Chan183

As buildings become energy producers as well as consumers, integrating these decentralized energy systems at the neighborhood and at the district scale enables a further reduction in energy consumption and CO2 emissions. Reference Orehounig, Evins and Dorer184 This integration requires the modification of district heating networks Reference Lauster, Teichmann, Fuchs, Streblow and Mueller185 and smart grids that can deal with decentralized electricity production, consumption, and storage, including those associated with electric vehicles. Reference Siano186 There is a strong need for standardization to ensure the compatibility of the various technical installations at both the building and the district level, and this is an area where policy can make a difference.

Energy demand of buildings

To understand the energy demand of buildings and how it can be potentially changed, it is important to consider three different aspects, namely, (i) building energy efficiency, (ii) rebound effects, and (iii) occupant behavior, which we will do in the following.

Building energy efficiency

By using renewable energy sources, such as heat pumps, photovoltaics, or solar thermal energy, even a building with a suboptimal building envelope can be run sustainably. However, given the control function of the building envelope and the possibility to incorporate passive heating or cooling elements, a well-designed envelope can greatly increase a building’s energy efficiency and its indoor thermal comfort. Pacheco and co-workers Reference Pacheco, Ordóñez and Martínez187 evaluated the best design options for a number of building parameters, including orientation, shape, envelope system, passive heating and cooling mechanisms, shading, and glazing, to optimize the energy consumption. Passive design strategies were also studied in Ref. Reference Rodriguez-Ubinas, Montero, Porteros, Vega, Navarro, Castillo-Cagigal, Matallanas and Gutiérrez188 for plus energy houses. Furthermore, the design of the building envelope can be optimized with respect to its embodied energy, for example, with respect to the ideal insulation thickness as discussed by Wolgemuth et al. Reference Wohlgemuth, von Gunten, Manz, Zeyer and Althaus44 Considering primary energy, global warming potential, and environmental impact points, the optimal insulation thickness is higher when outdoor temperatures are lower, indoor temperatures higher, the building smaller, and the environmental impact of the heat generation higher. For Switzerland, 20 cm of conventional insulation with a U-value of ∼0.15 W/(m2 K) is considered optimal for most cases. Copiello Reference Copiello189 shows that the embodied energy of building materials can be predicted by their production costs and shows how the embodied energy increases from low-energy buildings, to passive houses and self sufficient buildings, while the operating energy goes to zero at the same time. The combined energy optimum is reached for passive houses. Besides a well-designed building envelope, the proper operation of all energy relevant building services is a necessary condition for a low-energy building (see Dynamic Behavior, Building Energy Management and Smart Grids section above). Regarding this aspect, modern machine learning algorithms have found applications in building performance optimization problems.

However, high-energy saving potential lies not in the optimization of building elements and its operation alone but also in the target settings for thermal comfort. As mentioned in the Thermal Comfort section, heat balance models of thermal comfort might be too conservative for the definition of the desired parameter range of thermal comfort. That implies that the heating or cooling devices are used more than actually necessary to achieve thermal comfort of the occupants.

The rebound effect, the energy savings deficit & the energy performance gap

Energy efficiency in buildings is not sufficient, though, to reach goals on energy use and climate change containment. Undoubtedly, buildings have become much more energy efficient in the last decades, but this development has been accompanied by the so-called “rebound effect” on different levels. An increase in energy efficiency of a product or service can lead to a lower price and, with that, to an increased demand for it. The partial or complete offset of the initial energy efficiency increase by this ensuing demand increase is called a rebound effect. When the efficiency is more than offset, the effect is sometimes called the “Jevons” paradox. Greening et al. Reference Greening, Greene and Difiglio190 describe the rebound effect for different energy-related products. For the case of space-heating, the authors find it to be around 10–30%, i.e., any technological improvement will only be 70–90% effective in reducing energy consumption. Similar results are presented in a review by Sorrell and co-workers. Reference Sorrell, Dimitropoulos and Sommerville191 Regarding energy consumption in buildings, the increased consumption described by the rebound effect stem from an increase in thermal comfort and air quality, e.g., by higher inside temperatures in the winter, longer heating periods during the year, and higher ventilation rates, as well as from an increase in the living area in many countries. For example, a significant increase in living space per person has been observed in Switzerland, with an increase from 30 to 41 m2/person from 1970 to 2013 in the city of Zürich Reference Böninger192 or in Germany, with an overall 13% increase between 1996 and 2006. 193 Hence, the improvement of building thermal efficiency, i.e., by lower U-values, heat pumps, solar thermal collectors, etc., has been partially compensated by warmer and bigger flats and offices.

There are two more similar effects, described by Galvin, Reference Galvin194 that are sometimes confused with the rebound effect but which have different mechanisms. The first is the “energy savings deficit”, defined as the shortfall of energy savings as a proportion of expected energy savings of a building retrofit. Earlier, Sunikka-Blank and Galvin call it the “prebound effect”. Examining existing data of 3400 homes in Germany, the authors found that, prior to the retrofit, the energy consumption was on an average 30% less than what was calculated. Hence, the saving potential of a retrofit measure was overestimated for these buildings. The second effect related to the rebound effect is the “energy performance gap”. This denotes the ratio between the overconsumption of energy and the design consumption of a building, i.e., it shows a discrepancy between planned and real energy consumption.

User behavior

The existence of these two last effects, the energy savings deficit and the energy performance gap, points toward the last of the three aspects influencing building energy demand, namely user behavior. User behavior can radically alter the energy performance of a given building. This is shown, for example, in a California building and monitoring project, where a new settlement of near-zero-energy homes was built besides a conventional settlement. The electricity bills of the occupants of the two different settlements were compared. The evaluation showed that while the mean energy use of the near-zero-energy inhabitants was considerably lower than their neighbors’ in the conventional homes, the distribution of energy use of both groups was fairly similar: both had inhabitants that used very little energy (or sometimes even had a surplus in case of the near-zero-energy homes) and others that had bills multiple times higher. Reference Kerr and Toy195 This shows that purely architectural measures are necessary but not sufficient conditions for low energy use in buildings. Kathryn Janda gives an overview on the pivotal role of occupants in building energy use. Reference Janda196 Unfortunately, this role is often neglected and is still poorly understood. According to Janda, energy intense user behavior can be explained (i) by a lack of information about how to save energy—this is the so-called information deficit model—or (ii) by habits, practices, and norms. Focusing on the first explanation, she calls for a better education of building users. One measure can be feedback: direct user feedback, e.g., through real-time consumption monitors, can bring improvements of up to 15%, with indirect feedback, e.g., bills, being less influential with savings of up to 10%. The impact of feedback is limited, though, as many users—outside the group of building professionals—seem to not have sufficient knowledge on how to improve energy use. Hence, Janda suggests that either the existing group of building professionals, like architects and planners, or a new professional group should take up the responsibility for public education on “building literacy”, i.e., how buildings can be operated with low energy use. A complementary approach is presented by Stevenson and Leaman who propose to more thoroughly take into account user feedback for the improvement of housing from an energy perspective. Reference Stevenson and Leaman197 In either case, it is clear that the problem of high energy use and carbon dioxide emissions cannot be solved on a technological level alone but that a strong focus on building users is a complimentary necessity.

Building retrofit

As building codes become more stringent and new buildings more energy efficient, retrofitting the existing building stock has gained more prominence for the reduction of overall energy consumption. For example, in the canton of Zürich, Switzerland, in 2013, more than 70% of the existing building stock had a total yearly energy consumption of more than 100 kW h/m2 and was built before 1990, whereas many new buildings use less than 50 kW h/m2. 198 That means that further improvements of new buildings only have a marginal effect on the energy consumption of the entire building stock. Taking into account the energy savings deficit (see above), the energy savings that can be realized by retrofitting these older buildings will most likely be smaller than expected, as the actual energy use of old buildings tends to be less than the calculated values. Nevertheless, it is crucial to address the issue of old, poorly insulated buildings with outdated building technology to reduce the energy consumption of the building stock as a whole.

An overview on building retrofitting is given by Ma and co-workers. Reference Ma, Cooper, Daly and Ledo199 The authors note the very low renovation rate as well as the strong potential to increase the environmental performance of existing buildings. They illustrate the different phases of a retrofit with the concomitant retrofit activities and describe how the most suitable options for a retrofit can be selected. For that, it is crucial to take into account a retrofit of the whole building, i.e., for both the building technology and the thermal envelope. Kumbaroğlu and Madlener used Monte Carlo simulations to find the economically optimal set of retrofit measures, maximizing the net present value of the building. Reference Kumbaroğlu and Madlener200 They reported that the economic appropriateness of retrofit measures strongly depend on energy prices, indicating that these might be the most important influencing factor of renovation rates. The authors also state that volatile energy prices make postponing the retrofit measure the more profitable option. Taking into account three target parameters, namely energy consumption, retrofit cost, and thermal discomfort hours, Asadi et al. Reference Asadi, da Silva, Antunes, Dias and Glicksman201 showed that genetic algorithms combined with artificial neural networks solve the optimization problem much faster than conventional approaches. The optimization results can be used to evaluate the impact of individual retrofit measures and to facilitate decision making in a retrofit project.

Even though the optimal retrofit solution for a given building can be well understood in terms of technology, barriers to the successful planning and execution of an energy retrofit exist on several levels as described by Girod and co-workers Reference Girod, Lang and Nägele202 : (i) structural (institutional or market related), (ii) behavioral (risk, availability of information, habits), and (iii) availability (capital, products, proper installation and use of the technology). The authors identified profitability and uncertainty with respect to costs and savings, access to capital, lack of information as well as correct installation as the most important barriers. A survey of more than 400 house owners Reference Achtnicht and Madlener203 finds access to capital, profitability, and furthermore a favorable opportunity (such as the need for replacement of a heating system) as requirements for a retrofit. This shows the importance not only to consider the technical but also the financial, behavioral, and political context of building retrofits to increase retrofit rates.

Conclusion

Various aspects of the science and technology of reducing energy demands of buildings are now well understood, and new materials and solutions are continuously developed for the building envelope and systems: airtight envelopes, superinsulation materials, triple and vacuum insulation glazing with switchable g-values, low-cost solar cells and modules, building integrated photovoltaics, heat pumps, heat and electrical storage, building energy management systems, and smart grids. Equally important is the continuous reduction in cost for these energy systems, which is a driver of intense R&D. In addition to technology, user behavior affects the energy performance, sometimes to an even larger extent than the technology, and research is ongoing on how to modify this behavior. In fact, a more detailed knowledge about user behavior patterns may guide future developments on the materials and technology side. Variations in climate, economic power, building traditions and, perhaps most importantly, public perception and attitude toward climate change, have resulted in vastly different adoption rates of energy-efficient materials and technologies for different parts of our planet. Thanks to a coherent energy policy, the enforcement of strict building codes and the adoption of new materials and technologies for energy savings (building envelope), energy generation (renewables), and energy storage, the energy consumption and greenhouse gas emissions per square meter of new buildings have been reduced dramatically in many areas of Europe during the last few decades, although these gains are offset by the per capita increases in the living area. As a result, the focus within Europe is shifting toward the retrofit of the existing building stock with its poorly insulated, nonairtight building envelopes and outdated building technology. For new construction, a decent energy performance is required to obtain a building permit and research efforts now also target thermal comfort, IAQ, and user behavior, in addition to energy efficiency and energy technology alone. In contrast, different perceptions of the risks and consequences of climate change in the United States have resulted in a less coherent energy policy and less stringent building codes. As a result, the adoption of energy saving materials and technologies is lagging behind Europe and this inertia is magnified globally because of the exemplary role of the United States, particularly with second and third world countries. The growth of the middle class in the countries like China, Brazil, and India, and their increasing demand for thermal comfort, will precipitate a strong increase in cooling energy demands, unless efficient and sustainable solutions can be implemented readily and quickly.

References

REFERENCES

Parmesan, C. and Yohe, G.: A globally coherent fingerprint of climate change impacts across natural systems. Nature 421(6918), 3742 (2003).Google Scholar
Christianson, G.E.: Greenhouse; the 200-Year Story of Global Warming (Walker & Company, New York, NY, 1999).Google Scholar
Easterling, D.R., Meehl, G.A., Parmesan, C., Changnon, S.A., Karl, T.R., and Mearns, L.O.: Climate extremes: Observations, modeling, and impacts. Science 289(5487), 20682074 (2000).CrossRefGoogle ScholarPubMed
Menzel, A., Sparks, T.H., Estrella, N., Koch, E., Aasa, A., Ahas, R., Alm-Kübler, K., Bissolli, P., Braslavská, O., and Briede, A.: European phenological response to climate change matches the warming pattern. Global Change Biol. 12(10), 19691976 (2006).CrossRefGoogle Scholar
McCright, A.M. and Dunlap, R.E.: Defeating Kyoto: The conservative movement’s impact on US climate change policy. Soc. Probl. 50(3), 348373 (2003).Google Scholar
Coumou, D. and Rahmstorf, S.: A decade of weather extremes. Nat. Clim. Change 2(7), 491496 (2012).Google Scholar
Leiserowitz, A.A.: American risk perceptions: Is climate change dangerous? Risk Anal. 25(6), 14331442 (2005).Google Scholar
Lorenzoni, I. and Pidgeon, N.F.: Public views on climate change: European and USA perspectives. Clim. Change 77(1–2), 7395 (2006).Google Scholar
Haines, A., Smith, K.R., Anderson, D., Epstein, P.R., McMichael, A.J., Roberts, I., Wilkinson, P., Woodcock, J., and Woods, J.: Policies for accelerating access to clean energy, improving health, advancing development, and mitigating climate change. Lancet 370(9594), 12641281 (2007).CrossRefGoogle ScholarPubMed
Biesbroek, G.R., Swart, R.J., Carter, T.R., Cowan, C., Henrichs, T., Mela, H., Morecroft, M.D., and Rey, D.: Europe adapts to climate change: Comparing national adaptation strategies. Global Environ. Change 20(3), 440450 (2010).Google Scholar
Tompkins, E.L., Adger, W.N., Boyd, E., Nicholson-Cole, S., Weatherhead, K., and Arnell, N.: Observed adaptation to climate change: UK evidence of transition to a well-adapting society. Global Environ. Change 20(4), 627635 (2010).CrossRefGoogle Scholar
Meinshausen, M., Meinshausen, N., Hare, W., Raper, S.C., Frieler, K., Knutti, R., Frame, D.J., and Allen, M.R.: Greenhouse-gas emission targets for limiting global warming to 2 °C. Nature 458(7242), 11581162 (2009).Google Scholar
Enerdata Statistical Yearbook (2016). Available at: https://yearbook.enerdata.net/ (accessed June 21, 2017).Google Scholar
He, Y., Xu, Y., Pang, Y., Tian, H., and Wu, R.: A regulatory policy to promote renewable energy consumption in China: Review and future evolutionary path. Renew. Energy 89, 695705 (2016).Google Scholar
Jacobsson, S. and Lauber, V.: The politics and policy of energy system transformation—Explaining the German diffusion of renewable energy technology. Energy Policy 34(3), 256276 (2006).Google Scholar
Chowdhury, S., Sumita, U., Islam, A., and Bedja, I.: Importance of policy for energy system transformation: Diffusion of PV technology in Japan and Germany. Energy Policy 68, 285293 (2014).CrossRefGoogle Scholar
Lauber, V. and Jacobsson, S.: The politics and economics of constructing, contesting and restricting socio-political space for renewables–The German Renewable Energy Act. Environ. Innov. Soc. Transit. 18, 147163 (2016).Google Scholar
Ürge-Vorsatz, D., Cabeza, L.F., Serrano, S., Barreneche, C., and Petrichenko, K.: Heating and cooling energy trends and drivers in buildings. Renewable Sustainable Energy Rev. 41, 8598 (2015).Google Scholar
Roberts, S.: Effects of climate change on the built environment. Energy Policy 36(12), 45524557 (2008).CrossRefGoogle Scholar
Pongiglione, M. and Calderini, C.: Sustainable structural design: Comprehensive literature review. J. Struct. Eng. 142(12), 4016139 (2016).Google Scholar
LaFrance, M.: Technology Roadmap: Energy Efficient Building Envelopes (International Energy Agency, Paris, 2013).Google Scholar
Mirasgedis, S., Georgopoulou, E., Sarafidis, Y., Balaras, C., Gaglia, A., and Lalas, D.: CO2 emission reduction policies in the Greek residential sector: A methodological framework for their economic evaluation. Energy Convers. Manage. 45(4), 537557 (2004).Google Scholar
Martinsen, D., Markewitz, P., and Vögele, P.M.S.: Roads to Carbon Reduction in Germany (International Workshop by Energy Modelling Forum, IEA and IIASA, Laxenburg, Austria, 2003).Google Scholar
Lechtenböhmer, S., Grimm, V., Mitze, D., Thomas, S., and Wissner, M.: Target 2020: Policies and Measures to Reduce Greenhouse Gas Emissions in the EU (Wuppertal Institut für Klima, Umwelt, Energie, Wuppertal, Germany, 2005).Google Scholar
Enviros Consulting Ltd.: Review and Development of Carbon Abatement Curves for Available Technologies as Part of the Energy Efficiency Innovation Review (Enviros, Prague, 2005).Google Scholar
Jaccard, M.K.: Construction and Analysis of Sectoral, Regional and National Cost Curves of GHG Abatement of Canada (Natural Resources Canada, Vancouver, 2002).Google Scholar
Koomey, J.G., Webber, C.A., Atkinson, C.S., and Nicholls, A.: Addressing energy-related challenges for the US buildings sector: Results from the clean energy futures study. Energy Policy 29(14), 12091221 (2001).Google Scholar
National Institute for Environmental Studies Japan: GHG Emissions and Climate Change (NIES, Tsukuba, 2004).Google Scholar
ERI National Development and Reform Commission: China National Energy Strategy and Policy to 2020 (ERI, Beijing, 2004).Google Scholar
Murakami, S., Levine, M.D., Yoshino, H., Inoue, T., Ikaga, T., Shimoda, Y., Miura, S., Sera, T., Nishio, M., and Sakamoto, Y.: Energy consumption and mitigation technologies of the building sector in Japan. In 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings IAQVEC (Tohoku University Press, Sendai, Japan, 2007).Google Scholar
Izrael, Y.A., Avdjuhsin, S.I., Nazarov, I.M., Kokorin, A.O., Nakhutin, A.I., and Yakovlev, A.F.: Russian Federation Climate Change Country Study, Climate Change Action Plan (Russian Federal Service for Hydrometeorology and Environmental Monitoring, Moscow, 1999).Google Scholar
Australian Greenhouse Office: National appliances and equipment programs: When you keep measuring it, you know even more about it—Projected impacts 2005–2020 (2005). Available at: www.energyrating.gov.au/ (accessed June 21, 2017).Google Scholar
Ürge-Vorsatz, D. and Novikova, A.: Potentials and costs of carbon dioxide mitigation in the world’s buildings. Energy Policy 36(2), 642661 (2008).Google Scholar
Ionescu, C., Baracu, T., Vlad, G-E., Necula, H., and Badea, A.: The historical evolution of the energy efficient buildings. Renewable Sustainable Energy Rev. 49, 243253 (2015).Google Scholar
Bozsaky, D.: The historical development of thermal insulation materials. Period. Polytech. 41(2), 4956 (2010).Google Scholar
A’zami, A.: Badgir in traditional Iranian architecture. International Conference “Passive and Low Energy Colling for the Built Environment (Santorini, Greece, 2005).Google Scholar
Stetson, T.D.: Improvement in window-glass (1865). Available at: http://google.com/patents/US49167 (accessed November 21, 2016).Google Scholar
80 years: The House of Tomorrow: Solar house history. Available at: http://solarhousehistory.com/blog/2013/4/21/80-years (accessed November 21, 2016).Google Scholar
SOLAR 7: History • Solar1. Available at: http://web.mit.edu/solardecathlon/solar1.html (accessed November 21, 2016).Google Scholar
Kusuda, T.: Early history and future prospects of building system simulation. In Proceedings of Building Simulation, Vol. 99 (1999); pp. 315.Google Scholar
Van Hoof, J.: Forty years of Fanger’s model of thermal comfort: Comfort for all? Indoor Air 18(3), 182201 (2008).Google Scholar
Feist, W. and Schnieders, J.: Energy efficiency—A key to sustainable housing. Eur. Phys. J.: Spec. Top. 176(1), 141153 (2009).Google Scholar
Voss, K., Goetzberger, A., Bopp, G., Häberle, A., Heinzel, A., and Lehmberg, H.: The self-sufficient solar house in Freiburg—Results of 3 years of operation. Sol. Energy 58(1), 1723 (1996).Google Scholar
Wohlgemuth, D., von Gunten, D., Manz, H., Zeyer, C., and Althaus, H-J.: Ökologisch optimale Dämmdicken bei Wohngebäuden. Bauphysik 37(5), 277283 (2015).CrossRefGoogle Scholar
Kaynakli, O.: A review of the economical and optimum thermal insulation thickness for building applications. Renewable Sustainable Energy Rev. 16(1), 415425 (2012).Google Scholar
Al-Homoud, M.S.: The effectiveness of thermal insulation in different types of buildings in hot climates. J. Therm. Envelope Build. Sci. 27(3), 235247 (2004).Google Scholar
Sadineni, S.B., Madala, S., and Boehm, R.F.: Passive building energy savings: A review of building envelope components. Renewable Sustainable Energy Rev. 15(8), 36173631 (2011).Google Scholar
Fennell, H.C. and Haehnel, J.: Setting airtightness standards. ASHRAE J. 47(9), 2631 (2005).Google Scholar
Dodoo, A., Gustavsson, L., and Sathre, R.: Primary energy implications of ventilation heat recovery in residential buildings. Energy Build. 43(7), 15661572 (2011).Google Scholar
Jelle, B.P.: Traditional, state-of-the-art and future thermal building insulation materials and solutions—Properties, requirements and possibilities. Energy Build. 43(10), 25492563 (2011).Google Scholar
Stec, A.A. and Hull, T.R.: Assessment of the fire toxicity of building insulation materials. Energy Build. 43(2–3), 498506 (2011).CrossRefGoogle Scholar
Tyagi, V.V. and Buddhi, D.: PCM thermal storage in buildings: A state of art. Renewable Sustainable Energy Rev. 11(6), 11461166 (2007).Google Scholar
Zinzi, M. and Agnoli, S.: Cool and green roofs. An energy and comfort comparison between passive cooling and mitigation urban heat island techniques for residential buildings in the Mediterranean region. Energy Build. 55, 6676 (2012).Google Scholar
Liu, K. and Baskaran, B.: Thermal performance of green roofs through field evaluation. In Proceedings for the First North American Green Roof Infrastructure Conference (Green Roofs for Healthy Cities, Ontario, Canada, 2003); pp. 110.Google Scholar
Santamouris, M.: Cooling the cities—A review of reflective and green roof mitigation technologies to fight heat island and improve comfort in urban environments. Sol. Energy 103, 682703 (2014).Google Scholar
Fioretti, R., Palla, A., Lanza, L.G., and Principi, P.: Green roof energy and water related performance in the Mediterranean climate. Build. Environ. 45(8), 18901904 (2010).Google Scholar
Castleton, H.F., Stovin, V., Beck, S.B.M., and Davison, J.B.: Green roofs; building energy savings and the potential for retrofit. Energy Build. 42(10), 15821591 (2010).CrossRefGoogle Scholar
Sheweka, S.M. and Mohamed, N.M.: Green facades as a new sustainable approach towards climate change. Energy Procedia 18, 507520 (2012).Google Scholar
Pérez, G., Rincón, L., Vila, A., González, J.M., and Cabeza, L.F.: Behaviour of green facades in Mediterranean continental climate. Energy Convers. Manage. 52(4), 18611867 (2011).Google Scholar
Djongyang, N., Tchinda, R., and Njomo, D.: Thermal comfort: A review paper. Renewable Sustainable Energy Rev. 14(9), 26262640 (2010).Google Scholar
Yang, L., Yan, H., and Lam, J.C.: Thermal comfort and building energy consumption implications—A review. Appl. Energy 115, 164173 (2014).Google Scholar
Kwong, Q.J., Adam, N.M., and Sahari, B.B.: Thermal comfort assessment and potential for energy efficiency enhancement in modern tropical buildings: A review. Energy Build. 68(Part A), 547557 (2014).Google Scholar
Cheng, Y., Niu, J., and Gao, N.: Thermal comfort models: A review and numerical investigation. Build. Environ. 47, 1322 (2012).Google Scholar
Holopainen, R., Tuomaala, P., Hernandez, P., Häkkinen, T., Piira, K., and Piippo, J.: Comfort assessment in the context of sustainable buildings: Comparison of simplified and detailed human thermal sensation methods. Build. Environ. 71, 6070 (2014).Google Scholar
Lim, S.S., Vos, T., Flaxman, A.D., Danaei, G., Shibuya, K., Adair-Rohani, H., Amann, M., Anderson, H.R., Andrews, K.G., Aryee, M., Atkinson, C., Bacchus, L.J., Bahalim, A.N., Balakrishnan, K., Balmes, J., Barker-Collo, S., Baxter, A., Bell, M.L., Blore, J.D., Blyth, F., Bonner, C., Borges, G., Bourne, R., Boussinesq, M., Brauer, M., Brooks, P., Bruce, N.G., Brunekreef, B., Bryan-Hancock, C., Bucello, C., Buchbinder, R., Bull, F., Burnett, R.T., Byers, T.E., Calabria, B., Carapetis, J., Carnahan, E., Chafe, Z., Charlson, F., Chen, H., Chen, J.S., Cheng, A.T-A., Child, J.C., Cohen, A., Colson, K.E., Cowie, B.C., Darby, S., Darling, S., Davis, A., Degenhardt, L., Dentener, F., Jarlais, Des, , D.C., Devries, K., Dherani, M., Ding, E.L., Dorsey, E.R., Driscoll, T., Edmond, K., Ali, S.E., Engell, R.E., Erwin, P.J., Fahimi, S., Falder, G., Farzadfar, F., Ferrari, A., Finucane, M.M., Flaxman, S., Fowkes, F.G.R., Freedman, G., Freeman, M.K., Gakidou, E., Ghosh, S., Giovannucci, E., Gmel, G., Graham, K., Grainger, R., Grant, B., Gunnell, D., Gutierrez, H.R., Hall, W., Hoek, H.W., Hogan, A., Hosgood, H.D., Hoy, D., Hu, H., Hubbell, B.J., Hutchings, S.J., Ibeanusi, S.E., Jacklyn, G.L., Jasrasaria, R., Jonas, J.B., Kan, H., Kanis, J.A., Kassebaum, N., Kawakami, N., Khang, Y-H., Khatibzadeh, S., Khoo, J-P., Kok, C., Laden, F., Lalloo, R., Lan, Q., Lathlean, T., Leasher, J.L., Leigh, J., Li, Y., Lin, J.K., Lipshultz, S.E., London, S., Lozano, R., Lu, Y., Mak, J., Malekzadeh, R., Mallinger, L., Marcenes, W., March, L., Marks, R., Martin, R., McGale, P., McGrath, J., Mehta, S., Mensah, G.A., Merriman, T.R., Micha, R., Michaud, C., Mishra, V., Mohd Hanafiah, K., Mokdad, A.A., Morawska, L., Mozaffarian, D., Murphy, T., Naghavi, M., Neal, B., Nelson, P.K., Nolla, J.M., Norman, R., Olives, C., Omer, S.B., Orchard, J., Osborne, R., Ostro, B., Page, A., Pandey, K.D., Parry, C.D.H., Passmore, E., Patra, J., Pearce, N., Pelizzari, P.M., Petzold, M., Phillips, M.R., Pope, D., Pope, C.A., Powles, J., Rao, M., Razavi, H., Rehfuess, E.A., Rehm, J.T., Ritz, B., Rivara, F.P., Roberts, T., Robinson, C., Rodriguez-Portales, J.A., Romieu, I., Room, R., Rosenfeld, L.C., Roy, A., Rushton, L., Salomon, J.A., Sampson, U., Sanchez-Riera, L., Sanman, E., Sapkota, A., Seedat, S., Shi, P., Shield, K., Shivakoti, R., Singh, G.M., Sleet, D.A., Smith, E., Smith, K.R., Stapelberg, N.J.C., Steenland, K., Stöckl, H., Stovner, L.J., Straif, K., Straney, L., Thurston, G.D., Tran, J.H., Van Dingenen, R., van Donkelaar, A., Veerman, J.L., Vijayakumar, L., Weintraub, R., Weissman, M.M., White, R.A., Whiteford, H., Wiersma, S.T., Wilkinson, J.D., Williams, H.C., Williams, W., Wilson, N., Woolf, A.D., Yip, P., Zielinski, J.M., Lopez, A.D., Murray, C.J.L., Ezzati, M., AlMazroa, M.A., and Memish, Z.A.: A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990–2010: A systematic analysis for the global burden of disease study 2010. Lancet 380(9859), 22242260 (2012).CrossRefGoogle ScholarPubMed
Sundell, J.: On the history of indoor air quality and health. Indoor Air 14(Suppl. 7), 5158 (2004).Google Scholar
Runeson-Broberg, R. and Norbäck, D.: Sick building syndrome (SBS) and sick house syndrome (SHS) in relation to psychosocial stress at work in the Swedish workforce. Int. Arch. Occup. Environ. Health 86(8), 915922 (2013).Google Scholar
Peng, R.D., Butz, A.M., Hackstadt, A.J., Williams, D.L., Diette, G.B., Breysse, P.N., and Matsui, E.C.: Estimating the health benefit of reducing indoor air pollution in a randomized environmental intervention. J. R. Statist. Soc. A 178(2), 425443 (2015).Google Scholar
Sundell, J., Levin, H., Nazaroff, W.W., Cain, W.S., Fisk, W.J., Grimsrud, D.T., Gyntelberg, F., Li, Y., Persily, A.K., Pickering, A.C., Samet, J.M., Spengler, J.D., Taylor, S.T., and Weschler, C.J.: Ventilation rates and health: Multidisciplinary review of the scientific literature. Indoor Air 21(3), 191204 (2011).Google Scholar
Bornehag, C.G., Blomquist, G., Gyntelberg, F., Järvholm, B., Malmberg, P., Nordvall, L., Nielsen, A., Pershagen, G., and Sundell, J.: Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to “dampness” in buildings and health effects (NORDDAMP). Indoor Air 11(2), 7286 (2001).Google Scholar
Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P.O., Gyntelberg, F., Hanssen, S.O., Harrison, P., Pickering, A., Seppänen, O., and Wouters, P.: Ventilation and health in non-industrial indoor environments: Report from a European Multidisciplinary Scientific Consensus Meeting (EUROVEN). Indoor Air 12(2), 113128 (2002).Google Scholar
Maddalena, R., Mendell, M.J., Eliseeva, K., Chan, W.R., Sullivan, D.P., Russell, M., Satish, U., and Fisk, W.J.: Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making. Indoor Air 25(4), 362370 (2015).Google Scholar
Park, J.S. and Yoon, C.H.: The effects of outdoor air supply rate on work performance during 8-h work period. Indoor Air 21(4), 284290 (2011).CrossRefGoogle ScholarPubMed
Seppänen, O., Fisk, W.J., and Lei, Q.H.: Ventilation and performance in office work. Indoor Air 16(1), 2836 (2006).Google Scholar
Haverinen-Shaughnessy, U., Moschandreas, D.J., and Shaughnessy, R.J.: Association between substandard classroom ventilation rates and students’ academic achievement. Indoor Air 21(2), 121131 (2011).Google Scholar
Lu, T., , X., and Viljanen, M.: A novel and dynamic demand-controlled ventilation strategy for CO2 control and energy saving in buildings. Energy Build. 43(9), 24992508 (2011).Google Scholar
Koebel, M., Rigacci, A., and Achard, P.: Aerogel-based thermal superinsulation: An overview. J. Sol-Gel Sci. Technol. 63(3), 315339 (2012).Google Scholar
Freedonia Market Study #2434: World Insulation (Freedonia, Cleveland, 2009).Google Scholar
Hale, R.C., La Guardia, M.J., Harvey, E., and Mainor, T.M.: Potential role of fire retardant-treated polyurethane foam as a source of brominated diphenyl ethers to the US environment. Chemosphere 46(5), 729735 (2002).Google Scholar
Blanco, F., García, P., Mateos, P., and Ayala, J.: Characteristics and properties of lightweight concrete manufactured with cenospheres. Cem. Concr. Res. 30(11), 17151722 (2000).CrossRefGoogle Scholar
Baetens, R., Jelle, B.P., Gustavsen, A., and Grynning, S.: Gas-filled panels for building applications: A state-of-the-art review. Energy Build. 42(11), 19691975 (2010).Google Scholar
Lux Research Market Study #17198: Mapping Advanced Insulation Materials to Markets: Assessing Aerogel, Vacuum Insulation Panel, and Phase-Change Material Opportunities Beyond Building Applications (2015).Google Scholar
Kwon, J-S., Jang, C.H., Jung, H., and Song, T-H.: Effective thermal conductivity of various filling materials for vacuum insulation panels. Int. J. Heat Mass Transfer 52(23), 55255532 (2009).CrossRefGoogle Scholar
Simmler, H. and Brunner, S.: Vacuum insulation panels for building application: Basic properties, aging mechanisms and service life. Energy Build. 37(11), 11221131 (2005).Google Scholar
Stahl, T., Brunner, S., Zimmermann, M., and Koebel, M.: Thermally insulating aerogel based rendering materials. Patent WO 2014090790 A1, 2014.Google Scholar
Fickler, S., Milow, B., Ratke, L., Schnellenbach-Held, M., and Welsch, T.: Development of high performance aerogel concrete. Energy Procedia 78, 406411 (2015).Google Scholar
Rezaei, S.D., Shannigrahi, S., and Ramakrishna, S.: A review of conventional, advanced, and smart glazing technologies and materials for improving indoor environment. Sol. Energy Mater. Sol. Cells 159, 2651 (2017).Google Scholar
Manz, H.: On minimizing heat transport in architectural glazing. Renew. Energy 33(1), 119128 (2008).Google Scholar
Jelle, B.P., Kalnæs, S.E., and Gao, T.: Low-emissivity materials for building applications: A state-of-the-art review and future research perspectives. Energy Build. 96, 329356 (2015).Google Scholar
Van Den Bergh, S., Hart, R., Jelle, B.P., and Gustavsen, A.: Window spacers and edge seals in insulating glass units: A state-of-the-art review and future perspectives. Energy Build. 58, 263280 (2013).Google Scholar
Jelle, B.P., Hynd, A., Gustavsen, A., Arasteh, D., Goudey, H., and Hart, R.: Fenestration of today and tomorrow: A state-of-the-art review and future research opportunities. Sol. Energy Mater. Sol. Cells 96, 128 (2012).Google Scholar
Gustavsen, A., Grynning, S., Arasteh, D., Jelle, B.P., and Goudey, H.: Key elements of and material performance targets for highly insulating window frames. Energy Build. 43(10), 25832594 (2011).Google Scholar
Thalfeldt, M., Pikas, E., Kurnitski, J., and Voll, H.: Facade design principles for nearly zero energy buildings in a cold climate. Energy Build. 67, 309321 (2013).Google Scholar
Hood, T.G., Vincent, S.M., and Booth, R.: High performance, thermally insulating multipane glazing structure. U.S. Patent No. 5156894 A, 1992.Google Scholar
Collins, R.E. and Simko, T.M.: Current status of the science and technology of vacuum glazing. Sol. Energy 62(3), 189213 (1998).Google Scholar
Simko, T. and Collins, R.E.: Vacuum glazing: Development, design challenges and commercialisation. Aust. J. Mech. Eng. 12(3), 305316 (2014).Google Scholar
Cuce, E. and Cuce, P.M.: Vacuum glazing for highly insulating windows: Recent developments and future prospects. Renewable Sustainable Energy Rev. 54, 13451357 (2016).Google Scholar
Buratti, C. and Moretti, E.: Experimental performance evaluation of aerogel glazing systems. In Energy Solutions for a Sustainable World—Proceedings of the Third International Conference on Applied Energy, May 16–18, 2011-Perugia, Italy, Vol. 97 (2012); pp. 430437.Google Scholar
Schultz, J.M., Jensen, K.I., and Kristiansen, F.H.: Super insulating aerogel glazing. Sol. Energy Mater. Sol. Cells 89(2–3), 275285 (2005).Google Scholar
Jensen, K.I., Schultz, J.M., and Kristiansen, F.H.: Development of windows based on highly insulating aerogel glazings. In Aerogels 7. Proceedings of the 7th International Symposium on Aerogels 7th International Symposium on Aerogels, Vol. 350 (Alexandria, VA, 2004); pp. 351357.Google Scholar
Reim, M., Körner, W., Manara, J., Korder, S., Arduini-Schuster, M., Ebert, H-P., and Fricke, J.: Silica aerogel granulate material for thermal insulation and daylighting. CISBAT’03: Innovation in Building Envelopes and Environmental Systems 79(2), 131139 (2005).Google Scholar
Raut, H.K., Ganesh, V.A., Nair, A.S., and Ramakrishna, S.: Anti-reflective coatings: A critical, in-depth review. Energy Environ. Sci. 4(10), 37793804 (2011).Google Scholar
Fernandes, L.L., Lee, E.S., McNeil, A., Jonsson, J.C., Nouidui, T., Pang, X., and Hoffmann, S.: Angular selective window systems: Assessment of technical potential for energy savings. Energy Build. 90, 188206 (2015).CrossRefGoogle Scholar
Gong, J., Kostro, A., Motamed, A., and Schueler, A.: Potential advantages of a multifunctional complex fenestration system with embedded micro-mirrors in daylighting. Sol. Energy 139, 412425 (2016).Google Scholar
Georg, A., Georg, A., Graf, W., and Wittwer, V.: Switchable windows with tungsten oxide. Vacuum 82(7), 730735 (2008).Google Scholar
Granqvist, C.G.: Electrochromic tungsten oxide films: Review of progress 1993–1998. Sol. Energy Mater. Sol. Cells 60(3), 201262 (2000).Google Scholar
Wittwer, V., Datz, M., Ell, J., Georg, A., Graf, W., and Walze, G.: Gasochromic windows. Sol. Energy Mater. Sol. Cells 84(1), 305314 (2004).Google Scholar
Hauch, A., Georg, A., Baumgärtner, S., Krašovec, U.O., and Orel, B.: New photoelectrochromic device. Electrochim. Acta 46(13), 21312136 (2001).Google Scholar
Parkin, I.P. and Manning, T.D.: Intelligent thermochromic windows. J. Chem. Educ. 83(3), 393 (2006).Google Scholar
Livage, J. and Ganguli, D.: Sol–gel electrochromic coatings and devices: A review. Sol. Energy Mater. Sol. Cells 68(3), 365381 (2001).Google Scholar
Lee, S., Deshpande, R., Parilla, P.A., Jones, K.M., To, B., Mahan, A.H., and Dillon, A.C.: Crystalline WO3 nanoparticles for highly improved electrochromic applications. Adv. Mater. 18(6), 763766 (2006).Google Scholar
Scherer, M.R., Li, L., Cunha, P., Scherman, O.A., and Steiner, U.: Enhanced electrochromism in gyroid-structured vanadium pentoxide. Adv. Mater. 24(9), 12171221 (2012).Google Scholar
Sialvi, M.Z., Mortimer, R.J., Wilcox, G.D., Teridi, A.M., Varley, T.S., Wijayantha, K.U., and Kirk, C.A.: Electrochromic and colorimetric properties of nickel(II) oxide thin films prepared by aerosol-assisted chemical vapor deposition. ACS Appl. Mater. Interfaces 5(12), 56755682 (2013).Google Scholar
Thakur, V.K., Ding, G., Ma, J., Lee, P.S., and Lu, X.: Hybrid materials and polymer electrolytes for electrochromic device applications. Adv. Mater. 24(30), 40714096 (2012).Google Scholar
Marcilla, R., Alcaide, F., Sardon, H., Pomposo, J.A., Pozo-Gonzalo, C., and Mecerreyes, D.: Tailor-made polymer electrolytes based upon ionic liquids and their application in all-plastic electrochromic devices. Electrochem. Commun. 8(3), 482488 (2006).Google Scholar
Runnerstrom, E.L., Llordés, A., Lounis, S.D., and Milliron, D.J.: Nanostructured electrochromic smart windows: Traditional materials and NIR-selective plasmonic nanocrystals. Chem. Commun. 50(73), 1055510572 (2014).Google Scholar
Stopper, J., Boeing, F., and Gstoehl, D.: Fluid Glass Façade Elements: Energy Balance of an Office Space with a Fluid Glass Façade (Munich, Germany, 2013).Google Scholar
Pimputkar, S., Speck, J.S., DenBaars, S.P., and Nakamura, S.: Prospects for LED lighting. Nat. Photonics 3(4), 180 (2009).Google Scholar
Krames, M.R., Shchekin, O.B., Mueller-Mach, R., Mueller, G.O., Zhou, L., Harbers, G., and Craford, M.G.: Status and future of high-power light-emitting diodes for solid-state lighting. J. Disp. Technol. 3(2), 160175 (2007).Google Scholar
US Energy Information Administration: Trends in Lighting in Commercial Buildings (US EIA, Washington, 2017).Google Scholar
Kumar, R. and Rosen, M.A.: A critical review of photovoltaic–Thermal solar collectors for air heating. Appl. Energy 88(11), 36033614 (2011).CrossRefGoogle Scholar
Tian, Y. and Zhao, C-Y.: A review of solar collectors and thermal energy storage in solar thermal applications. Appl. Energy 104, 538553 (2013).Google Scholar
Kennedy, C.E.: Review of Mid-to High-Temperature Solar Selective Absorber Materials, Vol. 1617 (National Renewable Energy Laboratory, Golden, CO, USA, 2002).Google Scholar
Zambolin, E. and Del Col, D.: Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions. Sol. Energy 84(8), 13821396 (2010).Google Scholar
Sanner, B., Karytsas, C., Mendrinos, D., and Rybach, L.: Current status of ground source heat pumps and underground thermal energy storage in Europe. Geothermics 32(4), 579588 (2003).Google Scholar
Trillat-Berdal, V., Souyri, B., and Fraisse, G.: Experimental study of a ground-coupled heat pump combined with thermal solar collectors. Energy Build. 38(12), 14771484 (2006).Google Scholar
Green, M.A., Emery, K., Hishikawa, Y., Warta, W., and Dunlop, E.D.: Solar cell efficiency tables (Version 45). Prog. Photovoltaics 23(1), 19 (2015).Google Scholar
Omer, S., Wilson, R., and Riffat, S.: Monitoring results of two examples of building integrated PV (BIPV) systems in the UK. Renew. Energy 28(9), 13871399 (2003).Google Scholar
Yang, H., Zheng, G., Lou, C., An, D., and Burnett, J.: Grid-connected building-integrated photovoltaics: A Hong Kong case study. Sol. Energy 76(1), 5559 (2004).Google Scholar
Heinstein, P., Ballif, C., and Perret-Aebi, L-E.: Building integrated photovoltaics (BIPV): Review, potentials, barriers and myths. Green 3(2), 125156 (2013).Google Scholar
Petter Jelle, B., Breivik, C., and Drolsum Røkenes, H.: Building integrated photovoltaic products: A state-of-the-art review and future research opportunities. Sol. Energy Mater. Sol. Cells 100, 6996 (2012).Google Scholar
Shukla, A.K., Sudhakar, K., and Baredar, P.: A comprehensive review on design of building integrated photovoltaic system. Energy Build. 128, 99110 (2016).Google Scholar
Redweik, P., Catita, C., and Brito, M.: Solar energy potential on roofs and facades in an urban landscape. Sol. Energy 97, 332341 (2013).Google Scholar
Tsoutsos, T., Farmaki, E., and Mandalaki, M.: Solar energy for building supply. In Energy Performance of Buildings (2016); pp. 377398.Google Scholar
Lottner, V. and Mangold, D.: Status of seasonal thermal energy storage in Germany. Proc. Terrastock, 18 (University of Stuttgart, Stuttgart, Germany, 2000).Google Scholar
Stene, J.: Large-Scale Ground-Source Heat Pump Systems in Norway (IEA Annex 29 Workshop, Paris, France, 2008).Google Scholar
Hellström, G.: Large-Scale Applications of Ground-Source Heat Pumps in Sweden (IEA Heat Pump Annex 29 Workshop, Zurich, 2008).Google Scholar
Zalba, B., Marín, J.M., Cabeza, L.F., and Mehling, H.: Review on thermal energy storage with phase change: Materials, heat transfer analysis and applications. Appl. Therm. Eng. 23(3), 251283 (2003).CrossRefGoogle Scholar
Kaufmann, J. and Winnefeld, F.: Cement-based chemical energy stores. Patent WO2011147748 A1, 2011.Google Scholar
Dicaire, D. and Tezel, F.H.: Regeneration and efficiency characterization of hybrid adsorbent for thermal energy storage of excess and solar heat. Renew. Energy 36(3), 986992 (2011).Google Scholar
Hongois, S., Kuznik, F., Stevens, P., and Roux, J-J.: Development and characterisation of a new MgSO4–zeolite composite for long-term thermal energy storage. Sol. Energy Mater. Sol. Cells 95(7), 18311837 (2011).Google Scholar
Fumey, B., Weber, R., Gantenbein, P., Daguenet-Frick, X., Williamson, T., and Dorer, V.: Closed sorption heat storage based on aqueous sodium hydroxide. Energy Procedia 48, 337346 (2014).Google Scholar
Mette, B., Kerskes, H., and Drück, H.: Concepts of long-term thermochemical energy storage for solar thermal applications—Selected examples. Energy Procedia 30, 321330 (2012).Google Scholar
Khudhair, A.M. and Farid, M.M.: A review on energy conservation in building applications with thermal storage by latent heat using phase change materials. Energy Convers. Manage. 45(2), 263275 (2004).Google Scholar
Zhou, D., Zhao, C-Y., and Tian, Y.: Review on thermal energy storage with phase change materials (PCMs) in building applications. Appl. Energy 92, 593605 (2012).Google Scholar
Jamekhorshid, A., Sadrameli, S., and Farid, M.: A review of microencapsulation methods of phase change materials (PCMs) as a thermal energy storage (TES) medium. Renewable Sustainable Energy Rev. 31, 531542 (2014).Google Scholar
Florides, G. and Kalogirou, S.: Ground heat exchangers—A review of systems, models and applications. Renew. Energy 32(15), 24612478 (2007).Google Scholar
Yang, H., Cui, P., and Fang, Z.: Vertical-borehole ground-coupled heat pumps: A review of models and systems. Appl. Energy 87(1), 1627 (2010).Google Scholar
Wang, C., Chang, Y., Zhang, L., Pang, M., and Hao, Y.: A life-cycle comparison of the energy, environmental and economic impacts of coal versus wood pellets for generating heat in China. Energy 120, 374384 (2017).Google Scholar
Kasurinen, S., Jalava, P.I., Tapanainen, M., Uski, O., Happo, M.S., Mäki-Paakkanen, J., Lamberg, H., Koponen, H., Nuutinen, I., Kortelainen, M., Jokiniemi, J., and Hirvonen, M-R.: Toxicological effects of particulate emissions—A comparison of oil and wood fuels in small- and medium-scale heating systems. Atmos. Environ. 103, 321330 (2015).Google Scholar
Sippula, O., Hokkinen, J., Puustinen, H., Yli-Pirilä, P., and Jokiniemi, J.: Comparison of particle emissions from small heavy fuel oil and wood-fired boilers. Atmos. Environ. 43(32), 48554864 (2009).Google Scholar
Zambrana-Vasquez, D., Aranda-Usón, A., Zabalza-Bribián, I., Jañez, A., Llera-Sastresa, E., Hernandez, P., and Arrizabalaga, E.: Environmental assessment of domestic solar hot water systems: A case study in residential and hotel buildings. J. Cleaner Prod. 88, 2942 (2015).Google Scholar
Forman, C., Muritala, I.K., Pardemann, R., and Meyer, B.: Estimating the global waste heat potential. Renewable Sustainable Energy Rev. 57, 15681579 (2016).Google Scholar
Eichholz, H.D. and Schulz, S.: Practical recognized facts from a glass laboratory absorption heatpump for methyl-alcohol working fluid mixtures. Kälte und Klimatechnik 35, 378 (1982).Google Scholar
Jernqvist, Å., Abrahamsson, K., and Aly, G.: On the efficiencies of absorption heat transformers. Heat Recovery Syst. CHP 12(4), 323334 (1992).Google Scholar
Ziegler, F.: Recent developments and future prospects of sorption heat pump systems. Int. J. Therm. Sci. 38(3), 191208 (1999).Google Scholar
Shelton, S.V.: Resedential space conditioning with solid sorption technology. Heat Recovery Syst. CHP 13(4), 353361 (1993).Google Scholar
Meunier, F.: Solid sorption heat powered cycles for cooling and heat pumping applications. Appl. Therm. Eng. 18(9), 715729 (1998).Google Scholar
Henninger, S., Schmidt, F., and Henning, H-M.: Water adsorption characteristics of novel materials for heat transformation applications. Appl. Therm. Eng. 30(13), 16921702 (2010).Google Scholar
Dell, R.M. and Rand, D.A.J.: Energy storage—A key technology for global energy sustainability. J. Power Sources 100(1), 217 (2001).Google Scholar
Luthander, R., Widén, J., Nilsson, D., and Palm, J.: Photovoltaic self-consumption in buildings: A review. Appl. Energy 142, 8094 (2015).Google Scholar
Deane, J.P., Gallachóir, B.Ó., and McKeogh, E.: Techno-economic review of existing and new pumped hydro energy storage plant. Renewable Sustainable Energy Rev. 14(4), 12931302 (2010).CrossRefGoogle Scholar
Lund, H. and Salgi, G.: The role of compressed air energy storage (CAES) in future sustainable energy systems. Energy Convers. Manage. 50(5), 11721179 (2009).Google Scholar
Cheung, B., Carriveau, R., and Ting, D.S.: Storing energy underwater. Mech. Eng. 134(12), 38 (2012).Google Scholar
Divya, K. and Østergaard, J.: Battery energy storage technology for power systems—An overview. Electr. Power Syst. Res. 79(4), 511520 (2009).Google Scholar
Dufo-López, R., Lujano-Rojas, J.M., and Bernal-Agustín, J.L.: Comparison of different lead–acid battery lifetime prediction models for use in simulation of stand-alone photovoltaic systems. Appl. Energy 115, 242253 (2014).Google Scholar
Nykvist, B. and Nilsson, M.: Rapidly falling costs of battery packs for electric vehicles. Nat. Clim. Change 5(4), 329332 (2015).Google Scholar
Kim, H., Boysen, D.A., Newhouse, J.M., Spatocco, B.L., Chung, B., Burke, P.J., Bradwell, D.J., Jiang, K., Tomaszowska, A.A., and Wang, K.: Liquid metal batteries: Past, present, and future. Chem. Rev. 113(3), 20752099 (2012).Google Scholar
Kear, G., Shah, A.A., and Walsh, F.C.: Development of the all-vanadium redox flow battery for energy storage: A review of technological, financial and policy aspects. Int. J. Energy Res. 36(11), 11051120 (2012).Google Scholar
Wang, W., Luo, Q., Li, B., Wei, X., Li, L., and Yang, Z.: Recent progress in redox flow battery research and development. Adv. Funct. Mater. 23(8), 970986 (2013).Google Scholar
Khaligh, A. and Li, Z.: Battery, ultracapacitor, fuel cell, and hybrid energy storage systems for electric, hybrid electric, fuel cell, and plug-in hybrid electric vehicles: State of the art. IEEE Trans. Veh. Technol. 59(6), 28062814 (2010).Google Scholar
Dounis, A.I. and Caraiscos, C.: Advanced control systems engineering for energy and comfort management in a building environment—A review. Renewable Sustainable Energy Rev. 13(6–7), 12461261 (2009).Google Scholar
Ikeda, S. and Ooka, R.: Metaheuristic optimization methods for a comprehensive operating schedule of battery, thermal energy storage, and heat source in a building energy system. Appl. Energy 151, 192205 (2015).Google Scholar
Chan, M., Estève, D., Escriba, C., and Campo, E.: A review of smart homes—Present state and future challenges. Comput. Meth. Prog. Bio. 91(1), 5581 (2008).Google Scholar
Dorer, V. and Weber, A.: Energy and CO2 emissions performance assessment of residential micro-cogeneration systems with dynamic whole-building simulation programs. Energy Convers. Manage. 50(3), 648657 (2009).Google Scholar
Široký, J., Oldewurtel, F., Cigler, J., and Prívara, S.: Experimental analysis of model predictive control for an energy efficient building heating system. Appl. Energy 88(9), 30793087 (2011).Google Scholar
Fong, K.F., Hanby, V.I., and Chow, T.T.: HVAC system optimization for energy management by evolutionary programming. Energy Build. 38(3), 220231 (2006).Google Scholar
Attia, S., Hamdy, M., O’Brien, W., and Carlucci, S.: Assessing gaps and needs for integrating building performance optimization tools in net zero energy buildings design. Energy Build. 60, 110124 (2013).Google Scholar
Magnier, L. and Haghighat, F.: Multiobjective optimization of building design using TRNSYS simulations, genetic algorithm, and artificial neural network. Build. Environ. 45(3), 739746 (2010).Google Scholar
Wang, J., Zhai, Z.J., Jing, Y., and Zhang, C.: Particle swarm optimization for redundant building cooling heating and power system. Appl. Energy 87(12), 36683679 (2010).Google Scholar
Oldewurtel, F., Parisio, A., Jones, C.N., Gyalistras, D., Gwerder, M., Stauch, V., Lehmann, B., and Morari, M.: Use of model predictive control and weather forecasts for energy efficient building climate control. Energy Build. 45, 1527 (2012).Google Scholar
Missaoui, R., Joumaa, H., Ploix, S., and Bacha, S.: Managing energy smart homes according to energy prices: Analysis of a building energy management system. Energy Build. 71, 155167 (2014).Google Scholar
Tsui, K.M. and Chan, S.C.: Demand response optimization for smart home scheduling under real-time pricing. IEEE Trans. Smart Grid 3(4), 18121821 (2012).Google Scholar
Orehounig, K., Evins, R., and Dorer, V.: Integration of decentralized energy systems in neighbourhoods using the energy hub approach. Appl. Energy 154, 277289 (2015).Google Scholar
Lauster, M., Teichmann, J., Fuchs, M., Streblow, R., and Mueller, D.: Low order thermal network models for dynamic simulations of buildings on city district scale. Build. Environ. 73, 223231 (2014).Google Scholar
Siano, P.: Demand response and smart grids—A survey. Renewable Sustainable Energy Rev. 30, 461478 (2014).Google Scholar
Pacheco, R., Ordóñez, J., and Martínez, G.: Energy efficient design of building: A review. Renewable Sustainable Energy Rev. 16(6), 35593573 (2012).Google Scholar
Rodriguez-Ubinas, E., Montero, C., Porteros, M., Vega, S., Navarro, I., Castillo-Cagigal, M., Matallanas, E., and Gutiérrez, A.: Passive design strategies and performance of net energy plus houses. Energy Build. 83, 1022 (2014).Google Scholar
Copiello, S.: Economic implications of the energy issue: Evidence for a positive non-linear relation between embodied energy and construction cost. Energy Build. 123, 5970 (2016).Google Scholar
Greening, L.A., Greene, D.L., and Difiglio, C.: Energy efficiency and consumption—The rebound effect—A survey. Energy Policy 28(6–7), 389401 (2000).Google Scholar
Sorrell, S., Dimitropoulos, J., and Sommerville, M.: Empirical estimates of the direct rebound effect: A review. Energy Policy 37(4), 13561371 (2009).Google Scholar
Böninger, M.: Wie viel Wohnraum braucht der Mensch?—Stadt Zürich (2013). Available at: https://www.stadt-zuerich.ch/prd/de/index/statistik/publikationen-angebote/publikationen/webartikel/2013-03-28_Wie-viel-Wohnraum-braucht-der-Mensch.html (accessed December 5, 2016).Google Scholar
Wie private Haushalte die Umwelt nutzen—Höherer Energieverbrauch trotz Effizienzsteigerungen (Umwelt Bundesamt, 2006). Available at: https://www.destatis.de/DE/PresseService/Presse/Pressekonferenzen/2006/UGR/UBA_Hintergrundpapier.pdf?__blob=publicationFile (accessed December 5, 2016).Google Scholar
Galvin, R.: Making the “rebound effect” more useful for performance evaluation of thermal retrofits of existing homes: Defining the “energy savings deficit” and the “energy performance gap”. Energy Build. 69, 515524 (2014).Google Scholar
Kerr, R. and Toy, D.: Final Report: Occupied Home Evaluation Results (Building Industry Research Alliance (BIRA), Stockton, CA, 2007). Available at: https://www.consol.ws/services/consulting/files/reports/Final_Report_16D2_OccupiedHomeEvaluationResults.pdf (accessed December 5, 2016).Google Scholar
Janda, K.B.: Buildings don’t use energy: People do. Archit. Sci. Rev. 54(1), 1522 (2011).Google Scholar
Stevenson, F. and Leaman, A.: Evaluating housing performance in relation to human behaviour: New challenges. Build. Res. Inf. 38(5), 437441 (2010).Google Scholar
Energieplanungsbericht 2013 (AWEL, Abteilung Energie, Zürich, 2013). Available at: https://www.zh.ch/internet/de/aktuell/news/medienmitteilungen/2014/energieplanungsbericht_zeigt_erfolge_und_herausforderungen.html (accessed October 18, 2017).Google Scholar
Ma, Z., Cooper, P., Daly, D., and Ledo, L.: Existing building retrofits: Methodology and state-of-the-art. Energy Build. 55, 889902 (2012).Google Scholar
Kumbaroğlu, G. and Madlener, R.: Evaluation of economically optimal retrofit investment options for energy savings in buildings. Energy Build. 49, 327334 (2012).Google Scholar
Asadi, E., da Silva, M.G., Antunes, C.H., Dias, L., and Glicksman, L.: Multi-objective optimization for building retrofit: A model using genetic algorithm and artificial neural network and an application. Energy Build. 81, 444456 (2014).Google Scholar
Girod, B., Lang, T., and Nägele, F.: Energieeffizienz in Gebäuden: Herausforderungen und Chancen für Energieversorger und Technologiehersteller (2014). Available at: http://www.sustec.ethz.ch/content/dam/ethz/special-interest/mtec/sustainability-and-technology/PDFs/SER_Final_report.pdf (accessed December 5, 2016).Google Scholar
Achtnicht, M. and Madlener, R.: Factors influencing German house owners’ preferences on energy retrofits. Energy Policy 68, 254263 (2014).Google Scholar
Figure 0

Table 1. Climate change programs at global, regional and national levels.

Figure 1

Table 2. Primary energy consumption for the years 1995/2005/2015 based on the Enerdata Statistical Yearbook.13

Figure 2

Table 3. Currently implemented technologies and measures with the largest energy savings potential, modified from Ref. 33.

Figure 3

Table 4. Different classical and contemporary construction styles.

Figure 4

Table 5. Comparison of conventional and superinsulation materials.

Figure 5

Figure 1. (a) Cross section of a vacuum insulation panel, (b) monolithic aerogel board (courtesy of BASF), (c) silica aerogel granulate, (d) silica aerogel blanket, (e) silica aerogel board, and (f) silica aerogel render.

Figure 6

Figure 2. Schematic cross section of WO3 based electrochromic glazing. The coloration of the electrochromic layer can be tuned by switching the redox state of the active electrochromic material layer, most typically WO3. The current is provided through a transparent conductive oxide layer (TCO). The device design is an electrochemical cell similar to a battery.

Figure 7

Table 6. Overview of common heat storage materials.138,139