Hostname: page-component-7bb8b95d7b-5mhkq Total loading time: 0 Render date: 2024-09-25T23:22:41.898Z Has data issue: false hasContentIssue false

A far ultraviolet-C light technology is effective for decontamination of items in proximity to sinks and is enhanced by a far UV-C reflective surface

Published online by Cambridge University Press:  25 September 2024

Claire E. Kaple
Affiliation:
Department of Molecular Biology and Microbiology, Case Western Reserve University School of Medicine, Cleveland, OH, USA
Samir Memic
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
Martin Mathew Varghese
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
Timothy J. Hebrink
Affiliation:
3M Corporate Research Lab, 3M, St Paul, MN, USA
Curtis J. Donskey*
Affiliation:
Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, OH, USA Geriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, OH, USA
*
Corresponding author: Curtis J. Donskey; Email: Curtis.Donskey@va.gov
Rights & Permissions [Opens in a new window]

Abstract

Background:

Dispersal of gram-negative bacilli from sink drains has been implicated as a source of transmission in multiple outbreaks.

Methods:

In an acute care hospital, we assessed how often patient care supplies and other frequently touched items were within 1 meter of sink drains. We tested the efficacy of a ceiling-mounted far ultraviolet-C (UV-C) light technology for decontamination of sink bowls and surfaces near sinks with and without a wall-mounted film that reflects far UV-C light.

Results:

Of 190 sinks assessed, 55 (29%) had patient care supplies or other frequently touched items within 1 meter of the drain. The far UV-C technology reduced Pseudomonas aeruginosa, Enterobacter cloacae and Candida auris on steel disk carriers by ≥1.5 log10 colony-forming units (CFU) in 45 minutes. On inoculated real-world items, ≥1.9 log10 CFU reductions in P. aeruginosa were achieved on sites in line with the light source versus 0.4–1.8 log10 CFU reductions on shaded surfaces. The addition of the reflective surface significantly enhanced efficacy in shaded sites (P < 0.01).

Conclusions:

In a hospital setting, patient care supplies and other frequently touched items were often in proximity to sinks. The far UV-C light technology could potentially be useful for sink decontamination in high-risk areas.

Type
Original Article
Creative Commons
This is a work of the US Government and is not subject to copyright protection within the United States. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America.
Copyright
© Department of Veterans Affairs, 2024.

Introduction

Numerous outbreaks of infections due to gram-negative bacilli have been linked to sinks and other wastewater drainage sites. Reference Volling, Ahangari and Bartoszko1Reference Aranega-Bou, Cornbill, Verlander and Moore12 To reduce the risk, current hand hygiene guidelines recommend that steps be taken to reduce environmental contamination associated with sinks and sink drains. Reference Glowicz, Landon and Sickbert-Bennett13 These steps include ensuring that medications and patient care supplies are not placed on surfaces within 1 meter of sinks, and disinfection of sink bowls and faucets daily. Reference Glowicz, Landon and Sickbert-Bennett13 However, limited information is available on how often patient care items and other frequently touched surfaces are in proximity to sinks in clinical settings. Moreover, daily disinfection of sink bowls and countertops or other items near sinks might have limited efficacy if organisms accumulate rapidly between episodes of cleaning.

In response to outbreaks, a variety of interventions have been used to address colonized sinks. These include repeated application of liquid or foam disinfectants, replacement of drainage pipes and traps, installation of heater-vibrator devices for trap disinfection, installation of self-disinfecting sinks and complete removal of sinks from patient rooms. Reference Hota, Hirji and Stockton2,Reference Donskey4,Reference Kotay, Chai, Guilford, Barry and Mathers6Reference Hopman, Tostmann and Wertheim10 However, such measures can be costly, labor-intensive, and potentially damaging to drainage systems. Thus, there is a need for additional approaches to reduce the risk for transmission of gram-negative bacilli colonizing sink drains. Here, we evaluated the efficacy of a far ultraviolet-C (UV-C) light technology that could be used for continuous or intermittent decontamination of sink bowls and surfaces near sinks. Far UV-C was evaluated rather than 254-nm UV-C due to safety considerations. Far UV-C doses within threshold limit values proposed by the American Conference of Governmental Industrial Hygienists (ACGIH) and the International Commission on Non-Ionizing Radiation Protection (ICNIRP) may be safe. Reference Blatchley, Brenner and Claus14 In addition, we conducted observations to determine the frequency and type of patient care supplies and other frequently touched items located in proximity to sinks in a hospital setting.

Methods

Survey of patient care supplies and other frequently touched items placed near sinks

An observational survey was completed at the Cleveland VA Medical Center. The observations were approved by the Cleveland VA Medical Center’s Research and Development Committee as a quality improvement project exempt from institutional review board review. During a 1-month period, 2 individuals recorded whether patient care supplies or other high-touch items were within 1 meter of sink drains in a convenience sample of rooms in patient care areas. There was no interaction with patients or staff during the survey. Sinks were classified as being in outpatient clinics, medical-surgical rooms, intensive care unit (ICU) rooms, or staff work areas. Items within 1 meter of sink drains were classified as patient care supplies, portable equipment, personal items, or other items.

Description of the far UV-C light technology and sink used for testing

The protocol for use of the far UV-C technology was approved by the Research and Development and Biosafety Committees at the Louis Stokes Cleveland VA Medical Center. The far UV-C technology (Mynatek, Inc., Oakland, CA) uses 3 krypton-chloride excimer lamps that emit a primary wavelength of 222 nm with filters to block emitted wavelengths greater than 230 nm. Reference Memic, Osborne, Cadnum and Donskey15 Each of the lamps has a field of illumination of 60°. The device includes proprietary sensors that detect the presence of people within the area of far UV-C light delivery. For the purposes of this study, the device was programmed to automatically shut off all 3 far UV-C lamps whenever people were detected within the area of far UV-C delivery and to automatically resume operation 30 seconds after they moved outside the area of far UV-C exposure.

A sink in a research laboratory was used for testing. The bowl is 56.3 cm2 diameter with a depth of 46.8 cm; the countertop is 0.8 meters from the floor. For sink decontamination, the device is intended to be mounted on the ceiling above and anterior to the front of the sink and directed toward the sink bowl. For these experiments, the device was mounted on a pole in front of the sink. The device was positioned just below the ceiling 2 meters from the floor above the front of the sink and angled toward the sink bowl.

Measurement of irradiance and far UV-C dosage with and without a far UV-C reflective surface on the wall behind the sink

Prior to the experiments, a radiometer (UIT2400 Handheld Light Meter for 222 nm (Ushio America, Cypress, CA) was used to measure irradiance in µW/cm2 at the locations of steel disk placement for testing and in locations where a person would stand in front of the sink. The sensor was pointed toward the light source. The far UV-C dose in mJ/cm2 was calculated at each site for a 45-minute exposure time. Measurements were taken with and without a wall-mounted visibly transparent Far-UVC film technology designed to reflect 200–250-nm UV-C light at normal angles (obtained from 3M Company, St Paul, MN) adhered on posterboard to the wall behind the sink.

Reduction in organisms on steel disk carriers placed in proximity to a sink

We tested the efficacy of the technology against Pseudomonas aeruginosa and Enterobacter cloacae isolates recovered from sink drains at the Cleveland VA Medical Center and Candida auris Antibiotic Resistance Bank (AR) #0385. The C. auris strain was included based on evidence that Candida species often colonize sink drains. Reference Piedrahita, Cadnum, Jencson, Shaikh, Ghannoum and Donskey16 A modification of the American Society for Testing and Materials (ASTM) standard quantitative disk carrier test method (ASTM E 2197-02) was used with 5% fetal calf serum as soil load. 17 A 10 µL inoculum containing 5–6 log10 colony-forming units (CFU) of the test organisms was spread to cover 20 mm steel disks. The disks were adhered to petri dishes and placed in a sink bowl adjacent to the drain, 0.30 meters from the drain on the countertop, and 0.91 meter from the drain at the height of the countertop. The disks were exposed to far-UV for 45 minutes and processed as previously described. Reference Memic, Osborne, Cadnum and Donskey15,Reference Piedrahita, Cadnum, Jencson, Shaikh, Ghannoum and Donskey16 A 45-minute continuous exposure was chosen based on previous data demonstrating that vegetative organisms on steel disk carriers 2 or 3 meters from the devices were reduced by >3 log10 after 45 minutes. Reference Memic, Osborne, Cadnum and Donskey15 Experiments were completed in triplicate. Log10 CFU reductions were calculated in comparison to untreated controls.

Reduction in gram-negative bacilli in biofilm recovered from sink drains

Because bacterial in sink drains may be present within a biofilm matrix, we assessed the efficacy of the technology against organisms associated with sink drain biofilm. Cotton-tipped swabs were used to recover biofilm material from the proximal 2.5 cm of pipes below the strainer of 2 hospital sinks with known P. aeruginosa or E. cloacae colonization. The swabs were used to inoculate 1-cm2 areas of the sink bowl and the sink countertop. The sink was then exposed to far UV-C light for 45 minutes. Pre-moistened cotton-tipped swabs were used to sample the inoculated sites and organisms were quantified as previously described. Experiments were completed in triplicate. Log10 CFU reductions were calculated in comparison to untreated controls.

Reduction in gram-negative bacilli on real-world items with and without a far UV-C reflective surface

To assess the efficacy of the technology in reducing organisms on real-world items, 10 µL containing 6 log10 CFU of the P. aeruginosa strain in 5% fetal calf serum was inoculated onto a 1 cm2 area on items identified in the survey as often being found near sinks in outpatient clinics. These included a canister of disinfectant wipes, a package of Kerlix gauze, and a box of gloves. Each item was inoculated on the horizontal top surface, a vertical side surface at a 90° angle from the light source, and a vertical shaded surface opposite the light source. After the inoculum air dried, the items were positioned on the sink countertop and exposed to far UV-C for 45 minutes.

Testing with real-world items was completed with and without the wall-mounted visibly transparent Far-UVC film technology designed to reflect 200–250-nm UV-C light adhered on posterboard to the wall behind the sink. The tests with the reflective material were included to assess whether the technology might increase efficacy in shadowed areas not in direct line of site of the far UV-C light. Pre-moistened cotton-tipped swabs were used to sample the inoculated surfaces and organisms were quantified by plating on selective media. Reference Hajar, Mana, Cadnum and Donskey5 Experiments were completed in triplicate. Log10 CFU reductions were calculated in comparison to untreated controls. Far UV-C delivery to sites with and without the reflective wall-mounted coating was assessed using the radiometer.

Evaluation of the feature that discontinues far UV-C output during use of the sink

To assess the feature that discontinues output when the sensors detect people within the area of far UV-C light delivery, research personnel performed hand washing 20 times and visually monitored far UV-C output (ie, the lamps emit visible light when operating). We assessed when the lamps turned off, if they remained off during hand washing, and when they turned back on after exiting the area in front of the sink. To determine the potential for individuals standing near the sink to be exposed to far UV-C when the device was on, the radiometer was used to measure irradiance at multiple locations in the room outside the area where the lamps would detect a person and automatically turn off.

Data analysis

Welch’s unequal variances t-test was used to compare reductions in P. aeruginosa in shaded locations on real-world items with versus without the reflective surfaces.

Results

Table 1 shows the results of the observational survey. Of 190 total sinks assessed, 55 (29%) had patient care supplies or other frequently touched items within 1 meter of the drain. The overall percentage of sinks with items within 1 meter of the drain was similar for sinks in outpatient clinics, medical-surgical rooms, ICU rooms, and staff work areas (25% to 34%). Figure 1 provides pictures of sinks with items present within 1 meter of the drain.

Table 1. Frequency and types of patient care supplies and other frequently touched items within 1 meter of the drain for sinks in an acute care hospital

Note. Data are shown as number (%). ICU: intensive care unit.

a other items included trash cans, towels and bedding, chairs, cannisters of disinfectant wipes, glove boxes, and tissues

Figure 1. Pictures of sinks with items present within 1 meter of the drain.

Figure 2 shows the irradiance readings and far UV-C dosages for 45 minutes of exposure at sites of steel disk placement and in locations where a person would stand in front of the sink during hand washing. The addition of the reflective wall surface increased the far UV-C irradiance measured in all the test sites on the counter and at 0.91 m from the drain. No far UV-C light was detected in locations lateral to and behind the device in locations where hand washing would occur without the reflective surface, whereas low levels of far UV-C were detected in these locations when the reflective surface was present.

Figure 2. Irradiance measurements and dosages of far ultraviolet-C light with a 45-minute exposure without (A) and with (B) a wall-mounted transparent film technology designed to reflect 200–250-nm UV-C light.

The far UV-C technology reduced P. aeruginosa, E. cloacae, and C. auris on the steel disk carriers in each of the test locations by ≥1.5 log10 CFU with a 45-minute exposure (Figure 3). For biofilm-associated P. aeruginosa or E. cloacae transferred from colonized sink drains, a 45-minute exposure to far UV-C light reduced recovery by ≥1.8 log10 CFU. On real-world test items, ≥1.9 log10 CFU reductions in P. aeruginosa were achieved in the sites on top of the test items that were in direct line of site of the far UV-C light source, but by 0.4 to 1.8 log10 CFU in the shaded sites (Figure 4); with the addition of the reflective surface, there was a significant increase in the reduction in P. aeruginosa in the shaded sites (P < 0.01).

Figure 3. Efficacy of a far ultraviolet-C (UV-C) light technology against Pseudomonas aeruginosa, Enterobacter cloacae, and Candida auris on steel disk carriers in 3 test locations with a 45-minute exposure. Error bars show standard error.

Figure 4. Efficacy of a far ultraviolet-C (UV-C) light technology with a 45-minute exposure against Pseudomonas aeruginosa inoculated onto real-world test items placed on a sink countertop with and without a wall-mounted transparent film technology designed to reflect 200–250-nm UV-C light. The items were inoculated on the horizontal top surface, a vertical side surface at a 90° angle from the light source, and a vertical shaded surface opposite the light source. Error bars show standard error.

During 20 episodes of hand washing, the device consistently turned off immediately when personnel entered the area in front of the sink where far UV-C was detectable. The device remained off during hand washing and turned back on 30 seconds after individuals moved away from the front of the sink. With the device on, no measurable levels of far UV-C light were detected in locations in the room outside of the area where the device detects people and automatically turns off.

Discussion

In response to outbreaks linked to sinks, a variety of interventions have been used to reduce the burden of colonization and removal of sinks from patient rooms has been considered in some situations. Reference Hota, Hirji and Stockton2,Reference Donskey4,Reference Kotay, Chai, Guilford, Barry and Mathers6Reference Hopman, Tostmann and Wertheim10 There is a need to evaluate new approaches as such interventions can be costly, labor-intensive, and difficult to sustain. In the current study, we demonstrated that a far UV-C light technology was effective in reducing gram-negative bacteria and C. auris on steel disk carriers placed in a sink bowl or on surfaces within 1 meter of the drain. On real-world items, the technology was effective in reducing P. aeruginosa in sites directly exposed to far UV-C light, but less effective on shaded surfaces. The addition of a reflective surface on the wall behind the sink substantially enhanced far UV-C delivery to the shaded surfaces with significant improvement in reductions in P. aeruginosa. These results suggest that the far UV-C light technology could be considered as an adjunct to manual cleaning and disinfection to reduce the risk for transmission of pathogens from sinks in high-risk areas. Reference Glowicz, Landon and Sickbert-Bennett13

One implication of our findings is that there is a need for healthcare facilities to assess the frequency and type of patient care supplies and other high-touch items located in proximity to sinks. Such assessments are particularly needed in ICUs and areas providing care for immunocompromised patients. Reference Volling, Ahangari and Bartoszko1,Reference Glowicz, Landon and Sickbert-Bennett13 Although most outbreaks related to colonized sinks have involved ICUs and other inpatient settings, there is a risk for transmission from contaminated sinks in outpatient settings providing care for immunocompromised patients. For example, an outbreak of Pantoea agglomerans bloodstream infections in an oncology clinic was linked to a colonized pharmacy sink. Reference Yablon, Dantes and Tsai18

There is a growing body of evidence that far UV-C doses within proposed threshold limit values may be safe. Reference Blatchley, Brenner and Claus14,Reference Hessling, Haag, Sieber and Vatter19Reference Görlitz, Justen and Rochette24 However, additional real-world studies are needed in occupied areas. Our findings demonstrate that the application tested here would result in minimal far UV-C exposure. The device consistently turned off and stayed off while people used the sink for hand washing. With the device directed toward the sink, no far UV-C irradiance was detected outside of the area immediately in front of the sink when the reflective material was not present. With the reflective material present, a low level of far UV-C light was detected outside the area where the device detects people and turns off. However, it is anticipated that this level of exposure would be well below the 8-hour threshold limit values proposed for far UV-C exposure (161 mJ/cm2 for eyes and 479 mJ/cm2 for skin). Reference Blatchley, Brenner and Claus14

Our study has some limitations. The observational evaluation of items in proximity to sinks was conducted in one facility and a convenience sample of sinks was assessed. The efficacy testing was conducted in a laboratory setting and with a high organism inoculum and only a 45-minute exposure. Additional studies are needed in real-world settings that are likely to include a lower organism burden and longer far UV-C exposure times; Hajar et al. Reference Hajar, Mana, Cadnum and Donskey5 recovered a median of 2 bacterial colonies (range, 1 to 80) from countertops after hand washing. We did not perform air sampling to assess for aerosolized pathogens or examine the impact of far UV-C on aerosolized organisms. Finally, we did not assess ozone production by the far UV-C technology. It is recommended that those using far UV-C technologies ask the manufacturers to provide information on the potential for their devices to generate ozone, and requirements for adequate ventilation to prevent ozone accumulation. Reference Blatchley, Brenner and Claus14

Conclusion

Patient care items and other frequently touched items were often in proximity to sinks in our healthcare facility. There is a need for assessments in other facilities and for development of strategies to reduce the presence of such items near sinks. In the setting of outbreaks linked to sinks, a ceiling-mounted far UV-C light technology could be useful in reducing the risk for transmission of organisms colonizing sink drains. Given that far UV-C delivery is substantially reduced in shaded areas, the addition of a far UV-C light reflective material should be considered if the technology is used.

Acknowledgments

We thank Mynatek, Inc. for providing the far-UV-C device used for testing and 3M Company for providing the patent pending visibly transparent far UV-C reflective film.

Financial support

Supported by the Department of Veterans Affairs.

Competing of interest

C.J.D has received research grants from Clorox and Pfizer. T.J.H is an employee of 3M and has pending patents for the visibly transparent far UV-C reflective film. All other authors report no conflicts of interest relevant to this article.

Footnotes

*

These authors contributed equally.

References

Volling, C, Ahangari, N, Bartoszko, JJ, et al. Are sink drainage systems a reservoir for hospital-acquired gammaproteobacteria colonization and infection? A systematic review. Open Forum Infect Dis 2020;8:ofaa590.CrossRefGoogle Scholar
Hota, S, Hirji, Z, Stockton, K, et al. Outbreak of multidrug-resistant Pseudomonas aeruginosa colonization and infection secondary to imperfect intensive care unit room design. Infect Control Hosp Epidemiol 2009;30:2533.CrossRefGoogle ScholarPubMed
Regev-Yochay, G, Margalit, I, Smollan, G, et al. Sink-traps are a major source for carbapenemase-producing Enterobacteriaceae transmission. Infect Control Hosp Epidemiol 2024;45:284291.CrossRefGoogle Scholar
Donskey, CJ. Update on potential interventions to reduce the risk for transmission of health care-associated pathogens from floors and sinks. Am J Infect Control 2023;51:A120A125.CrossRefGoogle ScholarPubMed
Hajar, Z, Mana, TSC, Cadnum, JL, Donskey, CJ. Dispersal of gram-negative bacilli from contaminated sink drains to cover gowns and hands during hand washing. Infect Control Hosp Epidemiol 2019;40:460462.CrossRefGoogle ScholarPubMed
Kotay, S, Chai, W, Guilford, W, Barry, K, Mathers, AJ. Spread from the sink to the patient: in situ study using green fluorescent protein (GFP) expressing-Escherichia coli to model bacterial dispersion from hand washing sink trap reservoirs. Appl Environ Microbiol 2017;83:e0332716.CrossRefGoogle Scholar
Gideskog, M, Falkeborn, T, Welander, J, Melhus, Å. Source control of Gram-negative bacteria using self-disinfecting sinks in a Swedish burn centre. Microorganisms 2023;11:965.CrossRefGoogle Scholar
Cahill, ME, Jaworski, M, Harcy, V, et al. Cluster of carbapenemase-producing carbapenem-resistant Pseudomonas aeruginosa among patients in an adult intensive care unit:– Idaho, 2021–2022. MMWR Morb Mortal Wkly Rep 2023;72:844846.CrossRefGoogle Scholar
Pejkovska, M, Ricciuto, D, Sultana, A, et al. Epidemiology of healthcare-associated Pseudomonas aeruginosa in intensive care units: are sink drains to blame? J Hosp Infect 2024;148:7786.Google Scholar
Hopman, J, Tostmann, A, Wertheim, H, et al. Reduced rate of intensive care unit acquired gram-negative bacilli after removal of sinks and introduction of ‘water-free’ patient care. Antimicrob Resist Infect Control 2017;6:59.CrossRefGoogle ScholarPubMed
Garvey, MI, Williams, N, Gardiner, A, et al. The sink splash zone. J Hosp Infect 2023;135:154156.CrossRefGoogle ScholarPubMed
Aranega-Bou, P, Cornbill, C, Verlander, NQ, Moore, G. A splash-reducing clinical handwash basin reduces droplet-mediated dispersal from a sink contaminated with Gram-negative bacteria in a laboratory model system. J Hosp Infect 2021;114:171174.CrossRefGoogle Scholar
Glowicz, JB, Landon, E, Sickbert-Bennett, EE, et al. SHEA/IDSA/APIC Practice recommendation: strategies to prevent healthcare-associated infections through hand hygiene: 2022 Update. Infect Control Hosp Epidemiol 2023;44:355376.CrossRefGoogle ScholarPubMed
Blatchley, ER III, Brenner, DJ, Claus, H, et al. Far UV-C radiation: an emerging tool for pandemic control. Crit Rev Env Sci Technol 2022;53:733753. doi: 10.1080/10643389.2022.2084315.CrossRefGoogle Scholar
Memic, S, Osborne, AO, Cadnum, JL, Donskey, CJ. Efficacy of a far-ultraviolet-C light technology for continuous decontamination of air and surfaces. Infect Control Hosp Epidemiol 2024;45:132134.CrossRefGoogle ScholarPubMed
Piedrahita, CT, Cadnum, JL, Jencson, AL, Shaikh, AA, Ghannoum, MA, Donskey, CJ. Environmental surfaces in healthcare facilities are a potential source for transmission of Candida auris and other Candida species. Infect Control Hosp Epidemiol 2017;38:11071109.CrossRefGoogle ScholarPubMed
ASTM International, Designation E2197. Standard quantitative disk carrier test method for determining bactericidal, virucidal, fungicidal, mycobactericidal, and sporicidal activities of chemicals. West Conshohocken, PA: ASTM International; 2011.Google Scholar
Yablon, BR, Dantes, R, Tsai, V, et al. Outbreak of Pantoea agglomerans bloodstream infections at an oncology clinic-Illinois, 2012–2013. Infect Control Hosp Epidemiol 2017;38:314319.CrossRefGoogle ScholarPubMed
Hessling, M, Haag, R, Sieber, N, Vatter, P. The impact of far-UVC radiation (200–230 nm) on pathogens, cells, skin, and eyes - a collection and analysis of a hundred years of data. GMS Hyg Infect Control 2021;16:Doc07.Google Scholar
Welch, D, Aquino de Muro, M, Buonanno, M, Brenner, DJ. Wavelength-dependent DNA photodamage in a 3-D human skin model over the far-UVC and germicidal UVC wavelength ranges from 215 to 255 nm. Photochem Photobiol 2022;98:11671171.CrossRefGoogle Scholar
Sugihara, K, Kaidzu, S, Sasaki, M, et al. One-year ocular safety observation of workers and estimations of microorganism inactivation efficacy in the room irradiated with 222-nm far ultraviolet-C lamps. Photochem Photobiol 2023;99:967974.CrossRefGoogle ScholarPubMed
Fukui, T, Niikura, T, Oda, T, et al. Exploratory clinical trial on the safety and bactericidal effect of 222-nm ultraviolet C irradiation in healthy humans. PLoS One 2020;15:e0235948.CrossRefGoogle ScholarPubMed
Kousha, O, O’Mahoney, P, Hammond, R, Wood, K, Eadie, E. 222 nm Far-UVC from filtered krypton-chloride excimer lamps does not cause eye irritation when deployed in a simulated office environment. Photochem Photobiol 2024;100:137145.CrossRefGoogle ScholarPubMed
Görlitz, M, Justen, L, Rochette, PJ, et al. Assessing the safety of new germicidal far-UVC technologies. Photochem Photobiol 2024;100:501520.CrossRefGoogle ScholarPubMed
Figure 0

Table 1. Frequency and types of patient care supplies and other frequently touched items within 1 meter of the drain for sinks in an acute care hospital

Figure 1

Figure 1. Pictures of sinks with items present within 1 meter of the drain.

Figure 2

Figure 2. Irradiance measurements and dosages of far ultraviolet-C light with a 45-minute exposure without (A) and with (B) a wall-mounted transparent film technology designed to reflect 200–250-nm UV-C light.

Figure 3

Figure 3. Efficacy of a far ultraviolet-C (UV-C) light technology against Pseudomonas aeruginosa, Enterobacter cloacae, and Candida auris on steel disk carriers in 3 test locations with a 45-minute exposure. Error bars show standard error.

Figure 4

Figure 4. Efficacy of a far ultraviolet-C (UV-C) light technology with a 45-minute exposure against Pseudomonas aeruginosa inoculated onto real-world test items placed on a sink countertop with and without a wall-mounted transparent film technology designed to reflect 200–250-nm UV-C light. The items were inoculated on the horizontal top surface, a vertical side surface at a 90° angle from the light source, and a vertical shaded surface opposite the light source. Error bars show standard error.