Hostname: page-component-79b67bcb76-x7pwn Total loading time: 0.177 Render date: 2021-05-14T01:55:25.163Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true }

Article contents

High-Current 14C Measurements on an HVE 1MV AMS System

Published online by Cambridge University Press:  09 February 2016

Matthias Klein
Affiliation:
High Voltage Engineering Europa B.V., PO Box 99, 3800 AB Amersfoort, the Netherlands. Email: info@highvolteng.com
A Gottdang
Affiliation:
High Voltage Engineering Europa B.V., PO Box 99, 3800 AB Amersfoort, the Netherlands. Email: info@highvolteng.com
D J W Mous
Affiliation:
High Voltage Engineering Europa B.V., PO Box 99, 3800 AB Amersfoort, the Netherlands. Email: info@highvolteng.com
Corresponding
E-mail address:

Abstract

High radiocarbon sample throughput is an increasingly important requirement of accelerator mass spectrometry (AMS) systems, which in turn requires high source output. To accomplish this, HVE AMS systems use a model SO-110B ion source, which can run at outputs of more than 200 μA 12C. It is known that high source output may compromise precision. To quantify this effect, we have tested an HVE 1MV AMS system for the influence of medium (100 μA) and high (200 μA) source outputs on the precision. These early measurements indicate for a 200 μA 12C source output, equivalent to a ≃1 kHz 14C count rate for Ox II samples, a 13C/12C precision of 1% and a 14C/12C precision of 3% can be obtained.

Type
Articles
Copyright
Copyright © 2013 by the Arizona Board of Regents on behalf of the University of Arizona 

Access options

Get access to the full version of this content by using one of the access options below.

References

Fallon, SJ, Guilderson, TP, Brown, TA. 2007. CAMS/LLNL ion source efficiency revisited. Nuclear Instruments and Methods in Physics Research B 259(1):106–10.CrossRefGoogle Scholar
Freeman, SPHT, Cook, GT, Dougans, AB, Naysmith, P, Wilcken, KM, Xu, S. 2010. Improved SSAMS performance. Nuclear Instruments and Methods in Physics Research B 268(7–8):715–7.CrossRefGoogle Scholar
Klein, M, Mous, DJW, Gottdang, A. 2004. Fast and accurate sequential injection AMS with gated Faraday cup current measurement. Radiocarbon 46(1):7782.CrossRefGoogle Scholar
Klein, M, Mous, DJW, Gottdang, A. 2006. A compact 1MV multi-element AMS system. Nuclear Instruments and Methods in Physics Research B 249(1–2):764–7.CrossRefGoogle Scholar
Klein, M, Staveren, HJ, Mous, DJW, Gottdang, A. 2007. Performance of the compact HVE 1 MV multi-element AMS system. Nuclear Instruments and Methods in Physics Research B 259(1):184–7.CrossRefGoogle Scholar
Roberts, ML, Burton, JR, Elder, KL, Longworth, BE, McIntyre, CP, von Reden, KF, Han, BX, Rosenheim, BE, Jenkins, WJ, Galutschek, E, McNichol, AP. 2010. A high-performance 14C accelerator mass spectrometer. Radiocarbon 52(2):228–35.CrossRefGoogle Scholar

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

High-Current 14C Measurements on an HVE 1MV AMS System
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

High-Current 14C Measurements on an HVE 1MV AMS System
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

High-Current 14C Measurements on an HVE 1MV AMS System
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *