Hostname: page-component-7c8c6479df-ws8qp Total loading time: 0 Render date: 2024-03-19T09:20:36.265Z Has data issue: false hasContentIssue false

The Use of Portable Oxygen Concentrators in Low-Resource Settings: A Systematic Review

Published online by Cambridge University Press:  02 March 2022

Craig D. Nowadly*
Affiliation:
Department of Emergency Medicine, Brooke Army Medical Center, Fort Sam Houston, TexasUSA
Daniel J. Portillo
Affiliation:
Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TexasUSA
Maxwell L. Davis
Affiliation:
Department of Respiratory Therapy, Keesler Air Force Base, Biloxi, Mississippi, USA
R. Lyle Hood
Affiliation:
Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TexasUSA Department of Emergency Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TexasUSA
Robert A. De Lorenzo
Affiliation:
Department of Emergency Medicine, The University of Texas Health Science Center at San Antonio, San Antonio, TexasUSA
*
Correspondence: Craig D. Nowadly, MD Department of Emergency Medicine 3551 Roger Brooke Dr Fort Sam Houston, Texas 78234 USA E-mail: craig.d.nowadly.mil@mail.mil

Abstract

Introduction:

Portable oxygen concentrators (POCs) are medical devices that use physical means to separate oxygen from the atmosphere to produce concentrated, medical-grade gas. Providing oxygen to low-resources environments, such as austere locations, military combat zones, rural Emergency Medical Services (EMS), and during disasters, becomes expensive and logistically intensive. Recent advances in separation technology have promoted the development of POC systems ruggedized for austere use. This review provides a comprehensive summary of the available data regarding POCs in these challenge environments.

Methods:

PubMed, Google Scholar, and the Defense Technical Information Center were searched from inception to November 2021. Articles addressing the use of POCs in low-resource settings were selected. Three authors were independently involved in the search, review, and synthesis of the articles. Evidence was graded using Oxford Centre for Evidence-Based Medicine guidelines.

Results:

The initial search identified 349 articles, of which 40 articles were included in the review. A total of 724 study subjects were associated with the included articles. There were no Level I systematic reviews or randomized controlled trials.

Discussion:

Generally, POCs are a low-cost, light-weight tool that may fill gaps in austere, military, veterinary, EMS, and disaster medicine. They are cost-effective in low-resource areas, such as rural and high-altitude hospitals in developing nations, despite relatively high capital costs associated with initial equipment purchase. Implementation of POC in low-resource locations is limited primarily on access to electricity but can otherwise operate for thousands of hours without maintenance. They provide a unique advantage in combat operations as there is no risk of explosive if oxygen tanks are struck by high-velocity projectiles. Despite their deployment throughout the battlespace, there were no manuscripts identified during the review involving the efficacy of POCs for combat casualties or clinical outcomes in combat. Veterinary medicine and animal studies have provided the most robust data on the physiological effectiveness of POCs. The success of POCs during the coronavirus disease 2019 (COVID-19) pandemic highlights the potential for POCs during future mass-casualty events. There is emerging technology available that combines a larger oxygen concentrator with a compressor system capable of refilling small oxygen cylinders, which could transform the delivery of oxygen in austere environments if ruggedized and miniaturized. Future clinical research is needed to quantify the clinical efficacy of POCs in low-resource settings.

Type
Systematic Review
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of the World Association for Disaster and Emergency Medicine

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Gómez-Chaparro, M, García-Sanz-Calcedo, J, Armenta Márquez, L. Analytical determination of medical gases consumption and their impact on hospital sustainability. Sustainability. 2018;10(8):2948.10.3390/su10082948CrossRefGoogle Scholar
World Health Organization. Model List of Essential Medicines, 22nd Ed. 2021. https://www.who.int/publications-detail-redirect/WHO-MHP-HPS-EML-2021.02. Accessed November 4, 2021.Google Scholar
Srivastava, U. Anesthesia gas supply: gas cylinders. Indian J Anaesth. 2013;57(5):500506.10.4103/0019-5049.120147CrossRefGoogle ScholarPubMed
Costantino, F, Gravio, GD, Tronci, M. “Simulation Model of the Logistic Distribution in a Medical Oxygen Supply Chain.” In: Proceedings of the 19th European Conference on Modelling and Simulation. Riga, Latvia; 2005:175-183.Google Scholar
Dobson, MB. Oxygen concentrators and cylinders. Int J Tuberc Lung Dis. 2001;5(6):520523.Google ScholarPubMed
Rybak, M, Huffman, LC, Nahouraii, R, et al. Ultraportable oxygen concentrator use in US Army special operations forward area surgery: a proof of concept in multiple environments. Mil Med. 2017;182(1):e1649e1652.10.7205/MILMED-D-16-00100CrossRefGoogle Scholar
Chatburn, RL, Williams, TJ. Performance comparison of 4 portable oxygen concentrators. Respiratory Care. 2010;55(4):433442.Google ScholarPubMed
World Health Organization. Technical specifications for oxygen concentrators. 2015. https://www.who.int/publications-detail-redirect/9789241509886. Accessed November 4, 2021.Google Scholar
Moher, D, Shamseer, L, Clarke, M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Systematic Reviews. 2015;4(1):1.10.1186/2046-4053-4-1CrossRefGoogle ScholarPubMed
OCEBM Levels of Evidence Working Group. Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence. http://www.cebm.net/index.aspx?o=5653. Accessed November 4, 2021.Google Scholar
Arnold, M. US Army Oxygen Generation System Development. US Army Medical Department; 2010. https://apps.dtic.mil/sti/citations/ADA581789. Accessed November 4, 2021.Google Scholar
Pollock, NW, Natoli, MJ. Chemical oxygen generation: evaluation of the Green Dot Systems, Inc portable, non-pressurized emOx device. Wilderness Environ Med. 2010;21(3):244249.10.1016/j.wem.2010.04.008CrossRefGoogle Scholar
Litch, JA, Bishop, RA. Oxygen concentrators for the delivery of supplemental oxygen in remote high-altitude areas. Wilderness Environ Med. 2000;11(3):189191.10.1580/1080-6032(2000)011[0189:OCFTDO]2.3.CO;2CrossRefGoogle ScholarPubMed
La Vincente, SF, Peel, D, Carai, S, et al. The functioning of oxygen concentrators in resource-limited settings: a situation assessment in two countries. Int J Tuberc Lung Dis. 2011;15(5):693699.10.5588/ijtld.10.0544CrossRefGoogle ScholarPubMed
Zhou, S, Chatburn, RL. Effect of the anatomic reservoir on low-flow oxygen delivery via nasal cannula: constant flow versus pulse flow with portable oxygen concentrator. Respir Care. 2014;59(8):11991209.10.4187/respcare.02878CrossRefGoogle ScholarPubMed
Gangidine, MM, Blakeman, TC, Branson, RD, Johannigman, JA. System design verification for closed loop control of oxygenation with concentrator integration. Mil Med. 2016;181(5 Suppl):177183.10.7205/MILMED-D-15-00150CrossRefGoogle ScholarPubMed
Chen, JZ, Katz, IM, Pichelin, M, et al. In vitro-in silico comparison of pulsed oxygen delivery from portable oxygen concentrators versus continuous flow oxygen delivery. Respir Care. 2019;64(2):117129.10.4187/respcare.06359CrossRefGoogle ScholarPubMed
Blakeman, TC, Rodriquez, D, Gerlach, TW, et al. Oxygen requirement to reverse altitude-induced hypoxemia with continuous flow and pulsed dose oxygen. Aerosp Med Hum Perform. 2015;86(4):351356.10.3357/AMHP.4184.2015CrossRefGoogle ScholarPubMed
Bunel, V, Shoukri, A, Choin, F, et al. Bench evaluation of four portable oxygen concentrators under different conditions representing altitudes of 2438, 4200, and 8000 m. High Alt Med Biol. 2016;17(4):370374.10.1089/ham.2016.0056CrossRefGoogle ScholarPubMed
Blakeman, TC, Rodriquez, D, Britton, TJ, et al. Evaluation of oxygen concentrators and chemical oxygen generators at altitude and temperature extremes. Mil Med. 2016;181(5 Suppl):160168.10.7205/MILMED-D-15-00130CrossRefGoogle ScholarPubMed
Sakaue, H, Suto, T, Kimura, M, et al. Oxygen inhalation using an oxygen concentrator in a low-pressure environment outside of a hospital. Am J Emerg Med. 2008;26(9):981984.10.1016/j.ajem.2007.12.009CrossRefGoogle Scholar
Blakeman, C, Dario Rodriquez, J, Branson, R. Bench evaluation of oxygen delivery using portable ventilators paired with portable oxygen concentrators. Respir Care. 2019;64(Suppl 10).Google Scholar
Dobson, MB. Oxygen concentrators for the smaller hospital--a review. Trop Doct. 1992;22(2):5658.10.1177/004947559202200204CrossRefGoogle ScholarPubMed
Enarson, P, La Vincente, S, Gie, R, et al. Implementation of an oxygen concentrator system in district hospital pediatric wards throughout Malawi. Bull World Health Organ. 2008;86(5):344348.10.2471/BLT.07.048017CrossRefGoogle ScholarPubMed
Qazi, S, Aboubaker, S, MacLean, R, et al. Ending preventable child deaths from pneumonia and diarrhea by 2025. Development of the integrated Global Action Plan for the Prevention and Control of Pneumonia and Diarrhea. Arch Dis Child. 2015;100(Suppl 1):S23-28.10.1136/archdischild-2013-305429CrossRefGoogle Scholar
Dobson, M, Peel, D, Khallaf, N. Field trial of oxygen concentrators in upper Egypt. Lancet. 1996;347(9015):15971599.10.1016/S0140-6736(96)91080-6CrossRefGoogle ScholarPubMed
Dobson, MB. Oxygen concentrators offer cost savings for developing countries. A study based on Papua New Guinea. Anaesthesia. 1991;46(3):217219.10.1111/j.1365-2044.1991.tb09413.xCrossRefGoogle ScholarPubMed
Howie, SRC, Hill, S, Ebonyi, A, et al. Meeting oxygen needs in Africa: an options analysis from the Gambia. Bull World Health Organ. 2009;87(10):763771.CrossRefGoogle ScholarPubMed
McCormick, BA, Eltringham, RJ. Anaesthesia equipment for resource-poor environments. Anaesthesia. 2007;62(Suppl 1):5460.CrossRefGoogle ScholarPubMed
Ritz, RH, Previtera, JE. Oxygen supplies during a mass casualty situation. Respir Care. 2008;53(2):215224; discussion 224-225.Google ScholarPubMed
Shrestha, BM, Singh, BB, Gautam, MP, Chand, MB. The oxygen concentrator is a suitable alternative to oxygen cylinders in Nepal. Can J Anaesth. 2002;49(1):812.10.1007/BF03020412CrossRefGoogle ScholarPubMed
Mokuolu, OA, Ajayi, OA. Use of an oxygen concentrator in a Nigerian neonatal unit: economic implications and reliability. Ann Trop Paediatr. 2002;22(3):209212.10.1179/027249302125001499CrossRefGoogle Scholar
Ahmed, T, Bautista, U, Hasib, A, et al. Oxygen Concentrators for Neonates in Low Resource Environments. December 2020. http://deepblue.lib.umich.edu/handle/2027.42/164437. Accessed November 4, 2021.Google Scholar
Pedersen, J, Nyrop, M. Anesthetic equipment for a developing country. Br J Anaesth. 1991;66(2):264270.CrossRefGoogle Scholar
Duke, T, Peel, D, Graham, S, et al. Oxygen concentrators: a practical guide for clinicians and technicians in developing countries. Ann Trop Paediatr. 2010;30(2):87101.10.1179/146532810X12637745452356CrossRefGoogle ScholarPubMed
Peel, D, Howie, SRC. Oxygen concentrators for use in tropical countries: a survey. J Clin Engineer. 2009;34(4):205209.10.1097/JCE.0b013e3181bb1329CrossRefGoogle Scholar
Cungi, PJ, Mathais, Q, D’Aranda, E, et al. Oxygen needs in austere environment: French military health service experience. medRXiv. 2020.10.1101/2020.04.06.20055780CrossRefGoogle Scholar
Johannigman, JA. Maintaining the continuum of en route care. Crit Care Med. 2008;36(7 Suppl):S377382.10.1097/CCM.0b013e31817e31e1CrossRefGoogle ScholarPubMed
Bouak, F. Oxygen Therapy: Description and Advances in Oxygen Delivery Systems. Turkey: CAN Publishing; 2004.Google Scholar
Defense Health Agency. Oxygen Generation for Deployed Army Casualty Care: DoD 2021.1 SBIR Solicitation. December 2020. https://www.sbir.gov/node/1841641. Accessed November 6, 2021.Google Scholar
Carter, JA, Baskett, PJ, The, Simpson PJ. “Permox” oxygen concentrator. Its mode of action, performance and potential application. Anaesthesia. 1985;40(6):560565.CrossRefGoogle ScholarPubMed
Rodriquez, D, Blakeman, TC, Dorlac, W, et al. Maximizing oxygen delivery during mechanical ventilation with a portable oxygen concentrator. J Trauma. 2010;69(Suppl 1):S8793.Google ScholarPubMed
Gustafson, JD, Yang, S, Blakeman, TC, et al. Pulsed dosed delivery of oxygen in mechanically ventilated pigs with acute lung injury. J Trauma Acute Care Surg. 2013;75(5):775779.10.1097/TA.0b013e3182a9252eCrossRefGoogle ScholarPubMed
Bordes, J, d’Aranda, E, Savoie, PH, et al. FiO2 delivered by a turbine portable ventilator with an oxygen concentrator in an Austere environment. J Emerg Med. 2014;47(3):306312.10.1016/j.jemermed.2014.04.033CrossRefGoogle Scholar
d’Aranda, E, Bordes, J, Bourgeois, B, et al. Fraction of inspired oxygen delivered by Elisée 350 turbine transport ventilator with a portable oxygen concentrator in an austere environment. J Spec Oper Med. 2016;16(3):3035.Google Scholar
Cardinale, M, Cungi, PJ, Bordes, J, et al. Maintaining a high inspired oxygen fraction with the Elisée 350 turbine transport ventilator connected to two portable oxygen concentrators in an austere environment. J Trauma Acute Care Surg. 2020;89(3):e59e63.10.1097/TA.0000000000002792CrossRefGoogle Scholar
Masroor, R, Iqbal, A, Buland, K, Kazi, WA. Use of a portable oxygen concentrator and its effect on the overall functionality of a remote field medical unit at 3650 meters elevation. Anaesthesia Pain Intensive Care. 2013;17(1):4550.Google Scholar
Nguyen, C, Montcriol, A, Janvier, F, et al. Critical COVID-19 patient evacuation on an amphibious assault ship: feasibility and safety. A case series. BMJ Mil Health. 2021;167(4):224228.10.1136/bmjmilitary-2020-001520CrossRefGoogle Scholar
Department of Defense. DoD Dictionary of Military and Associated Terms: Joint Publication 1-02. November 2010. https://irp.fas.org/doddir/dod/jp1_02.pdf. Accessed November 4, 2021.Google Scholar
Coutu, P, Caulkett, N, Pang, D, Boysen, S. Efficacy of a portable oxygen concentrator with pulsed delivery for treatment of hypoxemia during equine field anesthesia. Vet Anaesth Analg. 2015;42(5):518526.10.1111/vaa.12246CrossRefGoogle ScholarPubMed
Burn, J, Caulkett, NA, Gunn, M, et al. Evaluation of a portable oxygen concentrator to provide fresh gas flow to dogs undergoing anesthesia. Can Vet J. 2016;57(6):614618.Google ScholarPubMed
Fahlman, A, Caulkett, N, Arnemo, JM, et al. Efficacy of a portable oxygen concentrator with pulsed delivery for treatment of hypoxemia during anesthesia of wildlife. J Zoo Wildl Med. 2012;43(1):6776.10.1638/2011-0064.1CrossRefGoogle ScholarPubMed
Fischer, R, Wanka, ER, Einhaeupl, F, et al. Comparison of portable oxygen concentrators in a simulated airplane environment. Respir Med. 2013;107(1):147149.10.1016/j.rmed.2012.10.001CrossRefGoogle Scholar
Chapman, M, Tagore, A, Ariyaprakai, N, et al. Critical Considerations for Fixed-Wing Air Medical Transports. JEMS. March 2019. https://www.jems.com/patient-care/critical-considerations-for-fixed-wing-air-medical-transports/. Accessed November 6, 2021.Google Scholar
Williams, PR. Characterization and feasibility of a portable oxygen concentrator for use with a mass casualty ventilator. December 2013. https://scholarworks.boisestate.edu/cgi/viewcontent.cgi?article=1729&context=td. Accessed November 6, 2021.Google Scholar
Usher, AD. Medical oxygen crisis: a belated COVID-19 response. Lancet. 2021;397(10277):868869.10.1016/S0140-6736(21)00561-4CrossRefGoogle ScholarPubMed
World Health Organization. COVID 19 and the oxygen bottleneck. Bull World Health Organ. 2020;98(9):586587.CrossRefGoogle Scholar
Cheah, PK, Steven, EM, Ng, KK, et al. The use of dual oxygen concentrator system for mechanical ventilation during COVID-19 pandemic in Sabah, Malaysia. Int J Emerg Med. 2021;14(1):30.10.1186/s12245-021-00354-9CrossRefGoogle ScholarPubMed
Invacare. Homefill Oxygen System Product Description. http://www.invacare.com/doc_files/10-160rev0413.pdf. Accessed November 6, 2021.Google Scholar
Copeland, G, Zilevicius, D, Bedolla, C, et al. Review of commercially available supraglottic airway devices for prehospital combat casualty care. Mil Med. 2022. Epub ahead of print.10.1093/milmed/usac021CrossRefGoogle ScholarPubMed
Berard, D, Navarro, JD, Bascos, G, et al. Novel expandable architected breathing tube for improving airway securement in emergency care. Mech Behav Biomed Mater. 2021;114:104211.10.1016/j.jmbbm.2020.104211CrossRefGoogle ScholarPubMed
Akhter, F, Schoppe, A, Navarro, O, et al. Characterization of a novel emergency suction device for combat medics and civilian first responders. J Med Device. 2019;13(4):041004.10.1115/1.4043738CrossRefGoogle Scholar
Portillo, D, Bayliss, L, Rivas, S, et al. Characterizing and tuning perfusion parameters within an innovative, versatile oxygenating perfusion system. Ann Biomed Eng. 2021;49(12):31543164.10.1007/s10439-021-02843-7CrossRefGoogle ScholarPubMed
Supplementary material: PDF

Nowadly et al. supplementary material

Nowadly et al. supplementary material

Download Nowadly et al. supplementary material(PDF)
PDF 293.5 KB