Hostname: page-component-76fb5796d-9pm4c Total loading time: 0 Render date: 2024-04-26T02:53:40.042Z Has data issue: false hasContentIssue false

The Role of Fundamental Material Parameters for the Fluorine Effect in the Oxidation Protection of Titanium Aluminides

Published online by Cambridge University Press:  01 February 2011

Hans-Eberhard Zschau
Affiliation:
zschau@dechema.de, DECHEMA e. V., Karl-Winnacker-Institut, Frankfurt am Main, Germany
Michael Schütze
Affiliation:
schuetze@dechema.de, DECHEMA e. V., Karl-Winnacker-Institut, Frankfurt am Main, Germany
Get access

Abstract

To improve the insufficient oxidation resistance of Titanium Aluminides at temperatures above 750°C the fluorine effect offers an innovative way. The focus of this paper is to define the fundamental material variables for the fluorine effect related to the macroscopic behaviour (oxidation resistance) and its long time stability. The thermodynamic model predicted the fluorine effect for the TiAl within a corridor of total fluorine amount in terms of partial pressures. To realize the fluorine effect the required F-concentration [in at.-%] within the near surface region had to be found. Using fluorine ion implantation several fluences within 5e15 and 5e17 F cm-2 were implanted with an energy of 20 keV. The implantation depth profiles were calculated by using the Monte Carlo simulation code T-DYN and verified experimentally by using the non-destructive PIGE - technique (Proton Induced Gamma-ray Emission). After oxidation tests at 800°C – 1000°C a value of 2e17 F cm-2 / 20 keV was determined as an optimal implantation parameter set. Following these results the maximal fluorine concentration was identified to be a fundamental material variable for starting the alumina formation with a required fluorine amount of about 40-45 at.-%. However this maximum fluorine concentration showed a rapid decrease to values less than 5 at.-% only after a few hours of oxidation (900°C and 1000°C) followed by a slow decrease. Therefore the maximum fluorine concentration Cmax – now located at the metal/oxide – interface – was identified to be a fundamental parameter for the long time stability. An exponential decay function containing a constant term of about 1 at.-% was found to describe the time behaviour of Cmax for isothermal and cyclic oxidation (900°C, 1000°C). Because the alumina scale on the surface acts as a diffusion barrier for fluorine, the stability of Cmax is strongly influenced by the F-diffusion into the metal. From the F-depth profiles the diffusion coefficient of fluorine into the TiAl at 900°C was determined as a fundamental parameter for the long-term stability of Cmax showing a value of 1.56e-15cm2/s.

Type
Research Article
Copyright
Copyright © Materials Research Society 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Rahmel, A., Quadakkers, W. J., Schütze, M., Mat. and Corr. 46, 271 (1995).Google Scholar
2. Kumagai, M., Shibue, K., Mok-Soon, K., Makoto, Y., Intermetallics, 4, 557 (1996).Google Scholar
3. Schütze, M., Hald, M., Mat. Sci. Eng., A239–240, 847 (1997).Google Scholar
4. Donchev, A., Gleeson, B., Schütze, M., Intermetallics 11, 387 (2003).Google Scholar
5. Schumacher, G., Dettenwanger, F., Schütze, M., Hornauer, U., Richter, E., Wieser, E., Möller, W., Intermetallics, 7, 1113 (1999).Google Scholar
6. Schumacher, G., Lang, C., Schütze, M., Hornauer, U., Richter, E., Wieser, E., Möller, W., Mat. and Corr., 50, 162 (1999).Google Scholar
7. Hornauer, U., Richter, E., Wieser, E., Möller, W., Schumacher, G., Lang, C., Schütze, M., Nucl. Instr. & Meth. in Phys. Res., B 148, 858 (1999).Google Scholar
8. Zschau, H.-E., Gauthier, V., Schütze, M., Baumann, H., Bethge, K., Proc. International Symposium Turbomat, June 17–19, 2002, Bonn, Ed. Kaysser, W., 210 (2002).Google Scholar
9. Zschau, H.-E., Gauthier, V., Schumacher, G., Dettenwanger, F., Schütze, M., Baumann, H., Bethge, K., Graham, M., OXID. MET., 59, 183 (2003).Google Scholar
10. Zschau, H.-E., Schütze, M., Baumann, H. and Bethge, K., Nucl. Instr. & Meth. in Phys. Res., B 240, 137 (2005).Google Scholar
11. Zschau, H.-E., Schütze, M., Baumann, H. and Bethge, K., Mat. Sc. For. 461–464, 505 (2004).Google Scholar
12. Ziegler, J., Biersack, J., Littmark, U., The stopping and range of ions in solids, Version 95, 1995, Pergamon Press, New York.Google Scholar
13. Tesmer, J. R., Nastasi, M. (Eds.), Handbook of Modern Ion Beam Materials Analysis, Materials Research Society, Pittsburgh 1995, PA, USAGoogle Scholar
14. Biersack, J., Nucl. Instr. & Meth. in Phys. Res. B 153, 398 (1999).Google Scholar
15. Zschau, H.-E., Schütze, M., Baumann, H. and Bethge, K., Nucl. Instr. & Meth. in Phys. Res., B 257, 383 (2007).Google Scholar
16. Zschau, H.-E., Neve, S., Masset, P. J., Schütze, M., Baumann, H., Bethge, K., Submitted to Nucl. Instr. & Meth. in Phys. Res.Google Scholar