Hostname: page-component-76fb5796d-zzh7m Total loading time: 0 Render date: 2024-04-25T07:37:37.481Z Has data issue: false hasContentIssue false

Development of Fatigue Pre-Cracking Method into Micro-Sized Specimens for Measuring Fracture Toughness

Published online by Cambridge University Press:  11 February 2011

K. Takashima
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, 226–8503, Japan
S. Koyama
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, 226–8503, Japan
K. Nakai
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, 226–8503, Japan
Y. Higo
Affiliation:
Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, 226–8503, Japan
Get access

Abstract

In our previous investigations [1, 2], we have demonstrated that the introduction of fatigue pre-crack ahead of a notch is required to measure reliable fracture toughness values even for micro-sized specimens. However, it is rather difficult to introduce a fatigue pre-crack into a micro-sized specimen as once a fatigue crack starts to grow then the fatigue fracture occurs within one thousand cycles and this makes it extremely difficult to control fatigue crack length. Therefore, a new fatigue pre-cracking method is required for measuring fracture toughness. In this investigation, a new fatigue pre-cracking method has been proposed for micro-sized specimens and fracture toughness tests were carried out for the micro-sized specimens with fatigue pre-crack. Micro-cantilever beam type specimens with dimensions of 10 × 10 × 50 μm3 were prepared from an electroless deposited Ni-P amorphous alloy thin film and notches were introduced by focused ion beam machining. Fatigue pre-cracks were introduced ahead of the notches by far-field cyclic compression method using a mechanical testing machine for micro-sized specimens (MFT2000). Fracture tests were also carried out using the testing machine. Fatigue pre-cracks with length of 0.2 μm were confirmed on the fracture surfaces ahead of the notches in the far-field cyclically compressed specimens. This indicates that the fatigue pre-cracking method developed in this investigation is promising for measuring accurate fracture toughness for micro-sized specimens for MEMS applications.

Type
Research Article
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Ichikawa, Y., Maekawa, S., Takashima, K., Shimojo, M., Higo, Y. and Swain, M. V., in Materials Science of Microelectromechanical Systems (MEMS) Devices II, edited by de Boer, M. P., Heuer, A. H., Jacobs, S. J. and Peeters, E., (Mater. Res. Soc. Proc. 605, Pittsburgh, PA, 2000), pp. 273278.Google Scholar
2. Takashima, K., Shimojo, M., Higo, Y. and Swain, M. V., ASTM STP-1413, 72 (2001).Google Scholar
3. Li, X. and Bhushan, B., Thin Solid Films, 315, 214 (1998).Google Scholar
4. Ding, J., Meng, Y. and Wen, S., Thin Solid Films, 371, 178 (2000).Google Scholar
5. Ballarini, R., Mullen, R. L., Yin, Y., Kahn, H., Stemmer, S. and Heuer, A. H., J. Mater. Res., 12, 915 (1997).Google Scholar
6. Kahn, H., Tayebi, N., Ballarini, R., Mullen, R. L. and Heuer, A. H., Sensor and Actuators A: Physical, 82, 274 (2000).Google Scholar
7. Takashima, K., Higo, Y., Sugiura, S. and Shimojo, M., Mater. Trans. 42, 68 (2001).Google Scholar
8. Takashima, K., Shimojo, M., Higo, Y. and Swain, M. V., ASTM STP-1413, 52 (2001).Google Scholar
9. Suresh, S. and Brockenbrough, J. R., Acta Metall., 36, 1455 (1988).Google Scholar
10. Suresh, S., Eng. Fract. Mech., 21, 453 (1985).Google Scholar
11. Higo, Y., Takashima, K., Shimojo, M., Sugiura, S., Pfister, B. and Swain, M. V., in Materials Science of Microelectromechanical Systems (MEMS) Devices II, edited by de Boer, M. P., Heuer, A. H., Jacobs, S. J. and Peeters, E., (Mater. Res. Soc. Proc. 605, Pittsburgh, PA, 2000), pp. 241246.Google Scholar
12. Okamura, H., Introduction to Linear Fracture Mechanics (Baifukan, Tokyo, 1976) p. 218 (in Japanese).Google Scholar