Hostname: page-component-788cddb947-xdx58 Total loading time: 0 Render date: 2024-10-12T16:09:26.594Z Has data issue: false hasContentIssue false

Long-term Corrosion of Zircaloy-4 and Zircaloy-2 by Continuous Hydrogen Measurement under Repository Condition

Published online by Cambridge University Press:  23 January 2013

Tsutomu Nishimura
Affiliation:
Kobe Steel, Ltd., 4-7-2 Iwaya-Nakamachi, Nada-ku, Kobe 657-0845, Japan
Tsuyoshi Tateishi
Affiliation:
Kobelco Research Institute, Inc., 1-5-5 Takatsukadai, Nishi-ku, Kobe 657-2271, Japan
Get access

Abstract

Corrosion behavior is a key issue for the waste disposal of irradiated metals, such as hulls and endpieces, and is considered to be a leaching source of radionuclides including C-14. However, little information about Zircaloy corrosion in anticorrosive conditions has been provided.

In the present study, long-term corrosion tests of Zircaloy-4 and Zircaloy-2 were performed in assumed disposal conditions (dilute NaOH solution, pH 12.5, 303 K) by using the gas flow system for 1500 days. The corrosion rate, which was determined by measuring gaseous hydrogen and the hydrogen absorbed in Zircaloy, decreased with immersion time and was lower than the value of 2×10−2 μm/y used in performance assessment (1500-day values: 5.84×10−3 and 5.66×10−3 μm/y for Zircaloy-4, 1000-day values: 8.81×10−3 μm/y for Zircaloy-2). The difference in corrosion behavior between Zircaloy 4 and Zircaloy-2 was negligible. The average values of the hydrogen absorption ratios for Zircaloy-4 and Zircaloy-2 during corrosion were 91% and 94%, respectively.

The hydrogen generation kinetics of both gas evolution and absorption into metal can be shown by a parabolic curve. This result indicates that the diffusion process controls the Zircaloy corrosion in the early corrosion stage of the present study, and that the thickness of the oxide film in this stage is limited to approximately 25 nm and may therefore be in the form of dense tetragonal zirconia.

Type
Articles
Copyright
Copyright © Materials Research Society 2013 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Federation of Electric Power Companies (FEPC) and Japan Atomic Energy Agency (JAEA), Second Progress Report on Research and Development for TRU Waste Disposal in Japan (2007).Google Scholar
Hillner, E., Corrosion of Zirconium-Base Alloys–An Overview, Zirconium in the Nuclear Industry, 3rd Int. Symp., ASTM STP 633, 211235 (1977).Google Scholar
Hillner, E. et al. ., Long-term Corrosion of Zircaloy Before and After Irradiation, J. Nucl. Mater. 278, 334 (2000).CrossRefGoogle Scholar
Sakuragi, T. et al. ., Corrosion Rates of Zircaloy 4 by Hydrogen Measurement under High pH, Low Oxygen and Low Temperature Conditions, Mater. Res. Soc. Symp. Proc. 1475, 311 (2012).CrossRefGoogle Scholar
Godlewski, J. et al. ., Raman Spectroscopy Study of the Tetragonal-to-Monoclinic Transition in Zirconium Oxide Scales and Determination of Overall Oxygen Diffusion by Nuclear Microanalysis of O18, Zirconium in the Nuclear Industry, 9th Int. Symp., ASTM STP 1132, 416436 (1991).Google Scholar
IAEA, Waterside Corrosion of Zirconium Alloys in Nuclear Power Plants, IAEA-TECDOC-996 (1998).Google Scholar
Sawabe, T. et al. ., Microstructure of Oxide Layers Formed on Zirconium Alloy by Air Oxidation, Uniform Corrosion and Fresh-Green Surface Modification, J. Nucl. Mater. 419, 310319 (2011).CrossRefGoogle Scholar