Hostname: page-component-564cf476b6-mb7zs Total loading time: 0.186 Render date: 2021-06-18T22:52:54.161Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true }

Improvements of a-Si:H/CsI(TI) X-RAY Detectors for Radiation Monitoring

Published online by Cambridge University Press:  21 February 2011

C. Manfredotti
Affiliation:
Experimental Physics Dept., University of Torino, Via Giuria 1, Torino, Ind Consorzio INFM, Italy
E. Vittone
Affiliation:
Experimental Physics Dept., University of Torino, Via Giuria 1, Torino, Ind Consorzio INFM, Italy
M. Turnaturi
Affiliation:
IRCI, Borgaro Torinese (TO), Italy
Get access

Abstract

Photosensitive a-Si:H p-i-n diodes, working in photovoltaic mode, have been coupled to CsI(T1) scintillators for dosimetry applications to X-ray monitoring in the energy range from 50 keV up to 15 MeV. A “mesa” approach for p-i-n diodes has been adopted both in order to better define the geometry and to obtain very low dark current. In order to optimize the geometry, a computer program has been created which simulates light generation in the scintillator, the collection by the detector and the photovoltaic current obtained as a function of exposure rate.

Measurements have been carried out in the X-rays energy ranges 50-240 keV, at 6MeV and at 15 MeV. Detectors are linear in response and shows a good sensitivity, with the capability of measuring dose rates as low as 60 mR/h.

The agreement between experimental data and simulation outputs can be considered good.

Type
Research Article
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below.

References

[1] Manfredotti, C., in Winter European Course on Amorphous Silicon, edited by Spear, W.E. and Manfredotti, C., (Folgaria, Italy, 1988).Google Scholar
[2] Antonuk, L.E., Boudry, T., Huong, W., Sham, D.L. Mc, Morton, E.J., Yorkston, J., Lange, M., Street, R.A., Med. Phys. 19, 1455 (1992)CrossRefGoogle Scholar
[3] Fujeda, I., Cho, G., Gee, J.D.T., Jung, T., Kaplan, S.N., Perez-Mendez, V., Wildermith, D., Street, R.A., IEEE Symp. Nucl. Sci., Washington 1990 Google Scholar
[4] Antonuk, L.E., Yorkston, J., Huang, W., Boundry, J., Morton, E.J., Longo, M.J., Street, R.A., Proc. Mat. Research Soc. Symposium, S. Francisco 1992 Google Scholar
[5] Manfredotti, C., Faccio, F., Fizzotti, F., Marchisio, R., Nucl. Instr. Meth. in Phys. Research. A322, 483 (1992)CrossRefGoogle Scholar
[6] Pochet, T. Dubeau, J. Equer, B. Karar, A., Hamel, L.A., Joum. of Appl. Phys. 68,1340 (1990)CrossRefGoogle Scholar
[7] Amato, G., Benedetto, G., Boarino, L. Spagnolo, R., Solid State Comm. 72,172 (1991)Google Scholar
[8] Tsuo, Y.S., Xu, Y., Baker, D.W., Deb, S.K., Mat. Research Soc. Proc. Symposium, Spring Meeting, Anaheim (1991)Google Scholar

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Improvements of a-Si:H/CsI(TI) X-RAY Detectors for Radiation Monitoring
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Improvements of a-Si:H/CsI(TI) X-RAY Detectors for Radiation Monitoring
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Improvements of a-Si:H/CsI(TI) X-RAY Detectors for Radiation Monitoring
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *