Hostname: page-component-848d4c4894-2pzkn Total loading time: 0 Render date: 2024-05-08T06:58:04.499Z Has data issue: false hasContentIssue false

Evaluation of Infection Resistance of Biological Implants through CMP based Micro-Patterning

Published online by Cambridge University Press:  03 September 2012

G. Bahar Basim
Affiliation:
Department of Mechanical Engineering, Ozyegin University, Istanbul, 34794, Turkey.
Zeynep Ozdemir
Affiliation:
Department of Mechanical Engineering, Ozyegin University, Istanbul, 34794, Turkey.
Ayse Karagoz
Affiliation:
Department of Mechanical Engineering, Ozyegin University, Istanbul, 34794, Turkey.
Get access

Abstract

Biomaterials are widely used for dental implants, orthopedic devices, cardiac pacemakers and catheters. One of the main concerns on using bio-implants is the risk of infection on the materials used. In this study, our aim is to quantify the effect of controlled surface roughness on the infection resistance of the titanium based bio-materials which are commonly used for orthopedic devices and dental implants. To modify the surface roughness of the surfaces in a controlled manner, Chemical Mechanical Polishing (CMP) technique, which is extensively used in semiconductor industry for the planarization of the interlayer dielectrics and metals, is utilized. To determine the infection resistance of the created films with varying surface roughness, bacteria growth response was studied on titanium plates after CMP.

Type
Articles
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Shirkhanzadeh, M., Azadegan, M., Liu, G. Q., Mater. Lett., 24 (1995) 712.10.1016/0167-577X(95)00059-3Google Scholar
2. Shibata, K, Kamegai, A. Titanium in dentistry: Biocompatibility of titanium. Quintessence, Tokyo, 1988, pp.35-41.Google Scholar
3. Miyakawa, O, Okawa, S, Kobayashi, M, Uematsu, K., Dent in Japan 34 (1998) F90–96.Google Scholar
4. Akhter, R, Okawa, S, Nakano, S, Kobayashi, M, Miyakawa, Dent Mater J 19 (2000) 10–21.10.4012/dmj.19.10Google Scholar
5. Kaufman, F.B., Thomson, D.B. Broadie, R.E., Jaso, M.A., Guthrie, W.L., Pearson, M.B., Small, M.B., Journal of the Electrochemical Society, 138,(1991) 3460.Google Scholar
6. Chathapuram, V.S., Du, T., Sundaram, K.B., Desai, V., Microelectronic Engineering 65 (2003) 478488.10.1016/S0167-9317(03)00177-1Google Scholar
7. Variola, F. Yi, J-H, Richert, L., Wuest, J.D., Rosei, F. Nanci, A., Biomaterials, 29 (2008) 12851298.10.1016/j.biomaterials.2007.11.040Google Scholar
8. Jouanny, I., Labdi, S., Aubert, P., Buscema, C., Aciejak, O., Berger, M-H., Guipont, V., Jeandin, M., Thin Solid Films, 518 (2010) 32123217.10.1016/j.tsf.2009.09.046Google Scholar
9. Kurella, A., Dahotre, N.B., Journal of Biomaterials Applications, 20 (2005) 450.10.1177/0885328205052974Google Scholar
10. Martinez, E., Engel, E., Planell, J.A., Samiteier, J., Annals of Anatomy, 191 (2009) 126135.10.1016/j.aanat.2008.05.006Google Scholar