Hostname: page-component-568f69f84b-8fhp6 Total loading time: 0.146 Render date: 2021-09-19T02:34:44.806Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true, "newUsageEvents": true }

3-Mercaptopropionic Acid modified Porous Silicon Substrate used in Hyperammonemia

Published online by Cambridge University Press:  01 February 2011

Dong-hwa Yun
Affiliation:
macrochem@korea.ac.kr, Korea University, Chemical & Biological Engineering, Anam-dong Seongbuk-Gu, Seoul, 136-701, Korea, Republic of, 82-2-3290-3722
Jun-Hyoung Chang
Affiliation:
scout38@korea.ac.kr, Korea University, Chemical & Biological Engineering, Anam-dong Seongbuk-Gu, Seoul, 136-701, Korea, Republic of
Woo-Jin Lee
Affiliation:
woji0922@nate.com, Korea University, Chemical & Biological Engineering, Anam-dong Seongbuk-Gu, Seoul, 136-701, Korea, Republic of
Suk-In Hong
Affiliation:
sihong@korea.ac.kr, Korea University, Chemical & Biological Engineering, Anam-dong Seongbuk-Gu, Seoul, 136-701, Korea, Republic of
Get access

Abstract

Amperometric urea sensor is more suitable than optical and potentiometric urea sensor to diagnose hyperammonemia. However, because sensitivity in low concentration decreases remarkably, despite amperometric urea sensor has been studied for a long time it has not been applied for clinical diagnosis. In this paper, a new structure for an amperometric urea sensor was fabricated by MEMS, electrochemical etching, and electrostatic covalent binding techniques. Until now most amperometric urea sensors have had a membrane fixed on top of the transducer. That method often leads to malfunction of the sensor, arising from problems such as inadequate membrane adhesion, insufficient mechanical stability, and low sensitivity. To solve these kinds of problems, urease (Urs) was immobilized by electrostatic covalent binding method on the porous silicon (PSi) substrate coated self-assembled monolayer (SAM). Electrostatic covalent binding method was used to keep anisotropic orientation of urease on SAM.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Senillou, A., Jaffrezic-Renault, A., Martelet, C. and Cosnier, S., Talanta 50, 219 (1999).CrossRefGoogle Scholar
2. Koncki, R., Radomska, A. and Glab, S., Talanta 52, 13 (2002).CrossRefGoogle Scholar
3. Milardovic, S., Kruhak, I. and Grabaric, B. S., Laboratory Robotics and Automation 11, 266 (1999).3.0.CO;2-D>CrossRefGoogle Scholar
4. Lobanov, O. V., Dubrovsky, T. B., Savitsky, A. P., Akindinov, D. E., Alexeev, I. V. and Savransky, V. V., Thin Solid Films 259, 85 (1995).CrossRefGoogle Scholar
5. Malitesta, C., F. Palmisano and Torsi, L., Analytical Chemistry 62, 2735 (1990).CrossRefGoogle Scholar
6. Campanella, L., Mazzei, F., Sammartino, M. P. and Tommassetti, M., Bioelectrochemistry and Bioenergetics 23, 195 (1990).CrossRefGoogle Scholar
7. Ho, W. O., Krause, S., McNeil, C. J., Pritchard, J. A., Armstrong, R. D., Athey, D. and Rawson, K., Analytical Chemistry 71, 1940 (1999).CrossRefGoogle Scholar
8. Hirose, S., Hayashi, M., Tamura, N., Kamidate, T., Karube, I. and Suzuki, S., Analytica Chimica Acta 151, 377 (1983).CrossRefGoogle Scholar
9. Osaka, T., Komaba, S., Fujino, Y., Matsuda, T. and Satoh, I., Journal of the Electrochemical Society 146(2), 615 (1999).CrossRefGoogle Scholar
10. Singhal, R., Gambhir, A., Pandey, M. K., Annapoorni, S. and Malhotra, B. D., Biosensor and Bioelectronics 17, 697 (2002).CrossRefGoogle Scholar
11. Mascini, M., Iannello, M. and Palleschi, G., Analytica Chimica Acta 146, 135 (1983).CrossRefGoogle Scholar
12. Kenji, Y., Yusuke, F., Tetsuya, O. and Ikuo, S., Sensors and Actuators B 76, 152 (2001).Google Scholar
13. Kallury, K. M. R., Lee, W. E. and Thompson, M., Analytical Chemistry 64(9), 1062 (1992).CrossRefGoogle Scholar
14. Wirde, M. and Gelius, U., Langmuir 15(19), 6370 (1999).CrossRefGoogle Scholar

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

3-Mercaptopropionic Acid modified Porous Silicon Substrate used in Hyperammonemia
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

3-Mercaptopropionic Acid modified Porous Silicon Substrate used in Hyperammonemia
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

3-Mercaptopropionic Acid modified Porous Silicon Substrate used in Hyperammonemia
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *