Hostname: page-component-65dc7cd545-54nbv Total loading time: 0.141 Render date: 2021-07-25T17:20:46.599Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true, "newUsageEvents": true }

Comparison of Commercial Microvacuum Sampling Cassettes for Settled Dust Analysis

Published online by Cambridge University Press:  14 March 2018

James R. Millette
Affiliation:
MVA, Inc.
Rights & Permissions[Opens in a new window]

Extract

Three commercially available vacuum samplers (also known as microvacuum samplers or microvacs) were examined for compliance with the Standard ASTM Methods for asbestos in settled dust. The American Society for Testing and Materials (ASTM) Standard Test Method (D5755-95) for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Concentration and the similar Method (D5756-95) for mass require that a sample be collected by vacuuming a known surface area with a standard 25 or 37 mm air sampling cassette using a plastic tube that is attached to the inlet orifice which acts as a nozzle.

Type
Research Article
Copyright
Copyright © Microscopy Society of America 1998

References

1. American Society for Testing and Materials, ASTM D5755 Method: “Standard Test Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Concentration”, 1995.

2. Zefon International, 2860 23rd Ave. N., St. Petersburg, FL 33713; [800-282-0073].

3. SKC, Inc. 863 Valley View Rd, Eighty Four, PA 15330 [800-752-8472].

4. Environmental Monitoring Systems, 164 Ashley Avenue, Charleston, SC 29403. [800-293-3003].

You have Access

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Comparison of Commercial Microvacuum Sampling Cassettes for Settled Dust Analysis
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Comparison of Commercial Microvacuum Sampling Cassettes for Settled Dust Analysis
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Comparison of Commercial Microvacuum Sampling Cassettes for Settled Dust Analysis
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *