Hostname: page-component-78c5997874-dh8gc Total loading time: 0 Render date: 2024-11-17T21:22:25.946Z Has data issue: false hasContentIssue false

Image Simulation of Small Pt Particles and its Application to Lattice Spacing Measurements in Catalysts

Published online by Cambridge University Press:  02 July 2020

S.-C. Y. Tsen
Affiliation:
Center for Solid State Science, Arizona State University, Tempe, AZ85287-1704
P. A. Crazier
Affiliation:
Center for Solid State Science, Arizona State University, Tempe, AZ85287-1704
C. López Cartes
Affiliation:
Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Inorgánica, Universidad de Cádiz, Cádiz, Spain
J. Liu
Affiliation:
Monsanto Company, 800 N. Lindbergh Blvd, U1E, St Louis, MO63167
J.J. Calvino
Affiliation:
Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Inorgánica, Universidad de Cádiz, Cádiz, Spain
Get access

Extract

The technique of high resolution imaging is important for characterizing the structure of small metal particle catalysts and nanophase materials. For bimetallic systems, it is possible to use local lattice parameter measurements to identify alloy compositions in ensembles of nanometer sized metal particles [1]. However, determining alloy composition is challenging because changes in lattice parameters of only a few percent must be reliably detected. We have performed measurements of the apparent d(111) fringe spacing on both simulated and experimental HREM images from Pt particles in the size range 15 - 35 Å. A series of initial image simulations of Pt cubeoctahedrons with 17 Å (201 atoms) and 34 Å (1289 atoms) in diameter have been studied in order to understand the effect of different parameters on the accuracy of lattice spacing. The clusters were built using the Rhodius program developed by Botana et al [2]. Starting with a bulk crystal we create cubeoctahedra by applying successive cuts along either the (111) or (100) direction. A supercell size of 50Å was selected and the particles were oriented at or close to the [110]. Images were calculated by the multi-slice techniques using both the CERIUS and EMS applications. The supercell was divided into 20 slices and the following parameters were used in the calculation Eo = 400 kV, Cs = 1mm, Δf= -320 Å, focal spread = 80 Å, convergence = 0.5 mrad and atomic vibration = 0.35Å.

Type
High Resolution Electron Microscopy
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.deRuijter, W. J., Sharma, R., McCartney, M.R. and Smith, D.J. (1995) Ultramicroscopy, 57,409CrossRefGoogle Scholar
2.Botana, et al, Electron Microscopy 2B (1994) 1085Google Scholar
3.Malm, J.-O. and O'Keefe, M.A. (1997) Ultramicroscopy, 68, 1323CrossRefGoogle Scholar
4. Funding was provided by Monsanto and the Industrial Associates Program of Arizona State University (ASU) and the project was performed in the Center for HREM at ASU.Google Scholar