Abstract

A customized-built high-temperature tensile creep setup is introduced. Dog-bone shaped miniaturized specimens made from Nimonic-75 were tested as reference materials at temperatures of 850 and 1000 °C under constant load to verify the setup’s accuracy. The results were compared to tensile creep tests with conventional (standard size) specimens at identical experimental conditions. The shape of the creep curves obtained in the miniaturized specimens exhibits a pronounced minimum creep rate, thus, being seemingly different from the ones obtained for the bulk samples which reveal a clear steady-state regime. This is partly due to the continuous increase of stress under constant load testing conditions and very likely affected by the much higher surface to volume ratio of the miniaturized specimens leading to the premature onset of tertiary creep. Still, a good agreement was obtained between the two specimen sizes with respect to the dependence of the steady-state (standard size) and minimum (miniaturized size) strain rate on applied stress at various temperatures leading to also comparable activation energies of the creep.

Type
Articles
Copyright
Copyright © Materials Research Society 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Contributing Editor: Mathias Göken

References

REFERENCES

Gianola, D.S. and Eberl, C.: Micro-and nanoscale tensile testing of materials. JOM 61(3), 24 (2009).CrossRefGoogle Scholar
Hemker, K.J. and Sharpe, W.N.: Microscale characterization of mechanical properties. Annu. Rev. Mater. Res. 37(1), 93 (2007).CrossRefGoogle Scholar
Zupan, M., Hayden, M.J., Boehlert, C.J., and Hemker, K.J.: Development of high-temperature microsample testing. Exp. Mech. 41(3), 242 (2001).CrossRefGoogle Scholar
Karanjgaokar, N.J., Oh, C-S., and Chasiotis, I.: Microscale experiments at elevated temperatures evaluated with digital image correlation. Exp. Mech. 51(4), 609 (2011).CrossRefGoogle Scholar
Peter, D., Otto, F., Depka, T., Nörtershäuser, P., and Eggeler, G.: High temperature test rig for inert atmosphere miniature specimen creep testing. Materialwiss. Werkstofftech. 42(6), 493 (2011).CrossRefGoogle Scholar
Mälzer, G., Hayes, R.W., Mack, T., and Eggeler, G.: Miniature specimen assessment of creep of the single-crystal superalloy LEK 94 in the 1000 °C temperature range. Metall. Mater. Trans. A 38(2), 314 (2007).CrossRefGoogle Scholar
Leisen, D., Rusanov, R., Rohlfing, F., Fuchs, T., Eberl, C., Riesch-Oppermann, H., and Kraft, O.: Mechanical characterization between room temperature and 1000 °C of SiC free-standing thin films by a novel high-temperature micro-tensile setup. Rev. Sci. Instrum. 86(5), 055104 (2015).CrossRefGoogle ScholarPubMed
Grossmann, B.V., Biermann, H., and Mughrabi, H.: Measurement of service-induced internal elastic strains in a single-crystal nickel-based turbine blade with convergent-beam electron diffraction. Philos. Mag. A 80(8), 1743 (2000).CrossRefGoogle Scholar
Albiez, J., Sprenger, I., Seemüller, C., Weygand, D., Heilmaier, M., and Böhlke, T.: Physically motivated model for creep of directionally solidified eutectics evaluated for the intermetallic NiAl–9Mo. Acta Mater. 110, 377 (2016).CrossRefGoogle Scholar
Heilmaier, M.: Modellkompatible Beschreibung des Kriech-und Zeitstandverhaltens oxiddispersionsgehärteter Nickelbasissuperlegierungen (model-based description of the creep deformation and fracture behavior of oxide-dispersion strengthened nickel-base superalloys). Ph.D. thesis, VDI-Verlag, Düsseldorf, 1993.Google Scholar
Heilmaier, M. and Reppich, B.: Creep lifetime prediction of oxide-dispersion-strengthened nickel-base superalloys: A micromechanically based approach. Metall. Mater. Trans. A 27(12), 3861 (1996).CrossRefGoogle Scholar
Nganbe, M. and Heilmaier, M.: High temperature strength and failure of the Ni-base superalloy PM 3030. Int. J. Plast. 25, 822 (2009).CrossRefGoogle Scholar
Eberl, C., Thompson, R., Gianola, D.S., and Bundschuh, S.: Digital image correlation and tracking (Matlab Central File ID:12413, The Mathworks, Inc., Natick, MA, 2006).Google Scholar
Eberl, C., Gianola, D.S., and Hemker, K.J.: Mechanical characterization of coatings using microbeam bending and digital image correlation techniques. Exp. Mech. 50(1), 85 (2010).CrossRefGoogle Scholar
Chu, T.C., Ranson, W.F., Sutton, M.A., and Peter, W.H.: Applications of digital-image-correlation techniques to experimental mechanics. Exp. Mech. 25(3), 232 (1985).CrossRefGoogle Scholar
Lecompte, D., Smits, A., Bossuyt, S., Sol, H., Vantomme, J., Van Hemelrijck, D., and Habraken, A.M.: Quality assessment of speckle patterns for digital image correlation. Opt. Lasers Eng. 44(11), 1132 (2006).CrossRefGoogle Scholar
Pan, B., Xie, H., Wang, Z., Qian, K., and Wang, Z.: Study on subset size selection in digital image correlation for speckle patterns. Opt. Express 16(10), 7037 (2008).CrossRefGoogle Scholar
Sutton, M.A., Yan, J.H., Tiwari, V., Schreier, H.W., and Orteu, J.J.: The effect of out-of-plane motion on 2D and 3D digital image correlation measurements. Opt. Lasers Eng. 46(10), 746 (2008).CrossRefGoogle Scholar
Frost, H.J. and Ashby, M.F.: Deformation Mechanism Maps (Pergamon Press, Oxford, 1982).Google Scholar
Krieg, F., Mosbacher, M., Fried, M., Affeldt, E., and Glatzel, U.: Creep and oxidation behaviour of coated and uncoated thin walled single crystal samples of the alloy PWA1484. In Superalloys 2016: Proc. 13th Inter. Symp. Superalloys, Hardy, M., Huron, E., Glatzel, U., Griffin, B., Lewis, B., Rae, C., Seetharaman, V., and Tin, S., eds. (Wiley-TMS, Hoboken, New Jersey, 2016); p. 773.CrossRefGoogle Scholar
Bensch, M., Fleischmann, E., Konrad, C.H., Fried, M., Rae, C.M.F., and Glatzel, U.: Secondary creep of thin-walled specimens affected by oxidation. In Superalloys 2012: Proc. 12th Inter. Symp. Superalloys, Huron, E.S., Reed, R.C., Hardy, M.C., Mills, M.J., Montero, R.E., Portella, P.D., and Telesman, J., eds. (Wiley-TMS, Hoboken, New Jersey, 2012); p. 387.Google Scholar
Gibbons, T.B.: Creep properties of Nimonic 90 in thin section. Met. Technol. 8(1), 472 (1981).CrossRefGoogle Scholar
Seetharaman, V. and Cetel, A.D.: Thickness debit in creep properties of PWA 1484. In Superalloys 2004: Proc. 10th Inter. Symp. Superalloys, Green, K.A., Pollock, T.M., and Harada, H., eds. (Wiley-TMS, Warrendale, Pennsylvania, 2004); p. 207.CrossRefGoogle Scholar
Wen, Z.X., Pei, H.Q., Li, D.F., Yue, Z.F., and Gao, J.Y.: Thickness influence on the creep response of DD6 Ni-based single-crystal superalloy. High Temp. Mater. Processes 35(9), 871 (2016).CrossRefGoogle Scholar