Hostname: page-component-8448b6f56d-c4f8m Total loading time: 0 Render date: 2024-04-23T10:47:43.001Z Has data issue: false hasContentIssue false

Surface mechanical properties of C implanted Ni

Published online by Cambridge University Press:  31 January 2011

M. Nastasi
Affiliation:
Los Alamos National Laboratory, Materials Science and Technology Division, Los Alamos, New Mexico 87545
J. -P. Hirvonen
Affiliation:
Department of Physics, University of Helsinki, Helsinki, Finland
T. R. Jervis
Affiliation:
Los Alamos National Laboratory, Materials Science and Technology Division, Los Alamos, New Mexico 87545
G. M. Pharr
Affiliation:
Department of Materials Science, Rice University, Houston, Texas 77251
W. C. Oliver
Affiliation:
Metals and Ceramic Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Get access

Abstract

Nickel foils, 165 μm thick, have been carbon implanted at 300 K with 2, 3, and 4.2 × 1017 C ions/cm2 and implanted with a two-step implantation of 2.1 × 1017 C/cm2 at 300 K followed by 2.1 × 1017 C/cm2 at 77 K. All implantations performed at 300 K result in the formation of the metastablc phase Ni3C while the two-step implantation produces an amorphous Ni/C alloy. Surface mechanical property studies showed that both the surface hardness and wear properties are correlated with chemistry (carbon dose), and that the friction coefficient is additionally dependent on the surface microstructure. It was found that both the wear rate and coefficient of friction were reduced as the volume fracion of Ni3C increased. At the highest dose implanted 4.2 × 1017 C/cm7, the coefficient of friction was found to be lower for the sample implanted half at 300 K and half at 77 K and possessing an amorphous structure compared to the sample implanted entirely at 300 K and possessing a crystalline Ni3C structure. Increases in the surface hardness were also observed with increasing carbon content, with the greatest hardness observed in samples implanted to a total dose of 4.2 × 1017 C/cm2. The hardness at this dose was not dependent on the implant conditions or the metastable phase formed.

Type
Articles
Copyright
Copyright © Materials Research Society 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Ion Beam Modification of Materials, edited by Ullrich, B. M. (North-Holland, Amsterdam, 1985).Google Scholar
2Poate, J. M. and Cullis, A. G., in Ion Implantation, edited by Hirvonen, J. K. (Academic, New York, 1980), p. 85.CrossRefGoogle Scholar
3Johnson, W. L., Cheng, Y-T., Rossum, M. Van, and Nicolet, M-A., Nucl. Instrum. Meth. B7/8, 657 (1875).Google Scholar
4Herman, H., Nucl. Instrum. Meth. 182/183, 887 (1981).CrossRefGoogle Scholar
5Hartley, N. E. W., Ref. 1, p. 321.Google Scholar
6Hirvonen, J. K. and Clayton, C. R., in Surface Modification and Alloying by Laser, Ion, and Electron Beams, edited by Poate, J. M., Foti, G., and Jacobson, D. C. (Plenum, New York, 1983), p. 323.CrossRefGoogle Scholar
7Follstsaedt, D. M., Knapp, J. A., Pope, L. E., Yost, F. G., and Picraux, S. T., Appl. Phys. Lett. 45, 529 (1984).CrossRefGoogle Scholar
8Carosella, C. A., Singer, I. L., Bowers, R. C., and Gossett, C. R., in Ion Implantation Metallurgy, edited by Preece, C. M. and Hirvonen, J. K. (AIME, Warrendale, PA, 1980), p. 103.Google Scholar
9Singer, I. L. and Barlak, T. M., Appl. Phys. Lett. 43, 457 (1983).CrossRefGoogle Scholar
10Follstsaedt, D. M., Yost, F. G., and Pope, L. E., in Ion Implantation and Ion Beam Processing of Materials, edited by Hubler, G. K., Clayton, C. R., Holland, O. W., and White, C. W. (North-Holland, New York, 1984), p. 655.Google Scholar
11Moine, P., Popoola, O., and Villain, J. P., Scr. Metall. 20, 305 (1986).CrossRefGoogle Scholar
12Takadoum, J., Pivin, J. C., Pollock, H. M., Ross, J. D. J., and Bernas, H., Nucl. Instrum. Meth. B18, 153 (1987).Google Scholar
13Ziegler, J. F., Biersack, J. P., and Littmark, U., The Stopping and Range of Ions in Solids (Pergamon, New York, 1984), Vol. 1.Google Scholar
14Oliver, W. C., Hutchings, R., and Pethica, J. B., ASTM Spec. Tech. Pub. 889, 90 (1986).Google Scholar
15Oliver, W. C. and Pethica, J. B. (unpublished research).Google Scholar
16Doerner, M. F. and Nix, W. D., J. Mater. Res. 1, 601 (1986).CrossRefGoogle Scholar
17Biersack, J. P. and Haggmark, L. G., Nucl. Instrum. Meth. 174, 257 (1980).CrossRefGoogle Scholar