Hostname: page-component-848d4c4894-4rdrl Total loading time: 0 Render date: 2024-06-24T01:39:22.230Z Has data issue: false hasContentIssue false

Measurement of small tissue volumes using Holden's apparatus

Published online by Cambridge University Press:  29 June 2007

J. D. T. Mason*
Affiliation:
Department of Otorhinolaryngology, Leicester Royal Infirmary, Leicester.
S. S. Hehar
Affiliation:
Departments of Otorhinolaryngology, University Hospital, Nottingham.
M. Holden
Affiliation:
Department of Medical Physics, University Hospital, Nottingham.
N. S. Jones
Affiliation:
Departments of Otorhinolaryngology, University Hospital, Nottingham.
*
Mr J. D. T. Mason, Department of Otorhinolaryngology, Leicester Royal Infirmary, Leicester LE1 5WW. Fax: 01162 586082

Abstract

A reproducible method for the estimation of volumes of small tissue samples was needed to allow comparison of the biological activity of tissue explants and to relate symptom improvement to procedures such as adenoidectomy or polypectomy. Holdens apparatus, which utilizes fluid displacement between two chambers, was compared to displacement in a 20 ml syringe. Two observers made four readings each on 20 tissue samples (range 0.37 to 4.70 ml) using both methods for comparison.

A two-way analysis of variance for replicated data gave an F ratio of 0.6885 (df 19; p>0.8) for Holden's apparatus, and an F ratio of 1.4307 (df 19; p>0.1) for the 20 ml syringe. The standard error of the mean for repeated readings on the same sample by an observer was 0.001 ml for Holden's apparatus and 0.014 ml for the syringe method. For accurate estimation of small tissue volumes within 0.01 ml we recommend Holden's apparatus.

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Aherne, W. A., Dunhill, M. S. (1982) Morphometry. Ch. 2 (The estimation of whole organ volume), Edward Arnold, London, pp 1112.Google Scholar
Mason, J. D. T., Smith, S. J., Jones, N. S., Majumdar, B., Read, R. C. (1994) An in vitro model measuring tryptase release from nasal mucosa in response to allergen challenge. Clinical Otolaryngology 19: 407409.Google Scholar
O'Flynn, P. (1993) Acoustic rhinometry: validation of volume changes following intranasal polypectomy. Clinical Otolaryngology 18: 423425.Google Scholar