Ultraviolet-C (UV-C) monitoring made simple: Colorimetric indicators to assess delivery of UV-C light by room decontamination devices
Published online by Cambridge University Press: 16 April 2021
Abstract
To evaluate the use of colorimetric indicators for monitoring ultraviolet-C (UV-C) light delivery to sites in patient rooms.
In laboratory testing, we examined the correlation between changes in color of 2 commercial colorimetric indicators and log10 reductions in methicillin-resistant Staphylococcus aureus (MRSA) and Clostridioides difficile spores with exposure to increasing doses of UV-C from a low-pressure mercury room decontamination device. In patient rooms, 1 of the colorimetric indicators was used to assess UV-C dose delivery to 27 sites in the room.
In laboratory testing, the manufacturer’s reference colors for MRSA and C. difficile reduction corresponded with doses of ∼10,000 and 46,000 µJ/cm2; these doses resulted in >3 log10 reductions in MRSA and C. difficile spores, respectively. In patient rooms, the colorimetric indicators demonstrated suboptimal delivery of UV-C dosing to shadowed areas, which was improved by providing cycles on each side of the patient bed rather than in a single position and altering device placement. Increasing duration of exposure increased the number of sites achieving adequate dosing to kill C. difficile spores.
Commercial colorimetric indicators provide rapid and easy-to-interpret information on the UV-C dose delivered to sites in patient rooms. The indicators may be useful for training environmental services personnel and optimizing the effectiveness of UV-C room decontamination devices.
- Type
- Original Article
- Information
- Copyright
- © The Author(s), 2021. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
References
- 6
- Cited by