Hostname: page-component-8448b6f56d-sxzjt Total loading time: 0 Render date: 2024-04-19T20:04:25.691Z Has data issue: false hasContentIssue false

Duodenoscope-Associated Outbreak of a Carbapenem Resistant Enterobacteriaceae

Published online by Cambridge University Press:  02 November 2020

Sung Ran Kim
Affiliation:
Korea University Guro Hospital
Joon Young Song
Affiliation:
Division of Infectious Diseases, Department of Internal Medicine, Korea University Medical College
Min Hee Cho
Affiliation:
Infection Control Unit, Korea University Guro Hospital
Ji Yeon Song
Affiliation:
Infection Control Unit, Korea University Guro Hospital
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: We describe and evaluate our outbreak of carbapenem-resistant K. pneumoniae transmitted by contaminated duodenoscopes during endoscopic retrograde cholangiopancreatography (ERCP) procedures. Methods: An outbreak investigation was performed when Klebsiella pneumoniae carbapenemase-producing K. pneumoniae (KPC-KP) were identified from bile specimens of 4 patients. The investigation included medical record review, practice audits, and surveillance cultures of duodenoscopes and environmental sites. If available, clinical specimens were obtained from patients who had undergone ERCP in the previous 3 months. Carbapenem-resistant Enterobacteriaceae (CRE) screening cultures were performed to identify additional patients until no CRE cases were detected during 2 consecutive weeks. Pulsed-field gel electrophoresis (PFGE) of KPC-KP isolates was implemented. Results: In total, 12 cases were identified with exposure to duodenoscope from February 2019 through April 2019, including 6 cases with infections and 6 asymptomatic carriers. Case-control analysis showed that 2 specific duodenoscopes would be associated with the KPC-KP outbreak. Duodenoscope reprocessing procedures did not deviate from manufacturer recommendations for reprocessing. After ethylene oxide (EO) gas sterilization, the outbreak was terminated. Conclusions: Meticulous cleaning protocol and enhanced surveillance are necessary to prevent outbreaks of CRE. Notably, enhanced cleaning measures, such as sterilization for duodenoscopes, would be required after procedures with KPC-KP carriers.

Funding: None

Disclosures: None

Type
Poster Presentations
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.