Hostname: page-component-848d4c4894-ttngx Total loading time: 0 Render date: 2024-05-13T12:32:35.027Z Has data issue: false hasContentIssue false

Arterial and end-tidal carbon dioxide pressure differences during laparoscopic colorectal surgery

Published online by Cambridge University Press:  01 January 2008

Y.-S. Kim*
Affiliation:
Department of AnesthesiologySt Vincent HospitalCollege of MedicineThe Catholic University of KoreaSeoul, South Korea
*
Correspondence to: Yong-Shin Kim, Department of Anesthesiology, St Vincent Hospital, College of Medicine, The Catholic University of Korea, #93 Ji-Dong, Paldal-Gu, Suwon 442-723, South Korea. E-mail: aneskim@catholic.ac.kr; Tel: +82 31 249 7214/7274; Fax: +82 31 258 4212

Abstract

Type
Correspondence
Copyright
Copyright © European Society of Anaesthesiology 2007

EDITOR:

Because laparoscopy with carbon dioxide (CO2) pneumoperitoneum increases CO2 loading by transperitoneal absorption and decreases both thoracic compliance and functional residual capacity (FRC), arterial (PaCO2) and end-tidal (PetCO2) carbon dioxide can increase during laparoscopy. These can be affected by the duration of pneumoperitoneum and body position. PetCO2 is widely used as an indicator of PaCO2 and hence adequacy of ventilation during laparoscopic surgery. However, careful consideration should be taken of the gradient between PaCO2 and PetCO2 (P(a−et)CO2) because PetCO2 may not reflect PaCO2 because of ventilation perfusion mismatching. P(a−et)CO2 either remains unchanged or may increase during laparoscopy, with an exaggerated response in the presence of cardiopulmonary disease [Reference Wittgen, Andrus and Fitzgerald1].

In previous studies, P(a−et)CO2 during laparoscopic surgery has been reported for short or intermediate durations of surgery [Reference Wittgen, Andrus and Fitzgerald1,Reference Bhavani-Shankar, Steinbrook, Brooks and Datta2], but not for prolonged durations of surgery. Laparoscopic colorectal surgery takes at least 5 h, and positioning in both Trendelenburg and reverse-Trendelenburg is required. The purpose of this study was to assess the effect of CO2 pneumoperitoneum on the P(a−et)CO2 gradient during prolonged pneumoperitoneum for laparoscopic colorectal surgery.

Sixteen healthy patients (12 males; 4 females), ASA physical status I (10 patients) or II (6 patients), scheduled for laparoscopic colorectal surgery were studied. The study was approved by the hospital Ethics Committee and written and informed consent was obtained from each patient. Patients with cardiopulmonary abnormality were excluded.

Patients received lidocaine 1 mg kg−1, propofol 2–2.5 mg kg−1 and rocuronium 0.8 mg kg−1 for induction of anaesthesia. After tracheal intubation, anaesthesia was maintained with 50% nitrous oxide and enflurane in oxygen with rocuronium for muscle relaxation.

A Drager capnograph (Drager Medical System, Danvers, MA, USA) was used to monitor the PetCO2. Mechanical ventilation was used with a tidal volume of 8–10 ml kg−1 and a rate of 10–14 breaths min−1 to maintain PetCO2 at a stable value between 30 and 40 mmHg during the procedure (inspiratory time : expiratory time ratio 1 : 2). After induction of general anaesthesia, a 22-G arterial cannula was introduced into the left radial artery after modified Allen’s test. A baseline (preinsufflation) arterial blood sample was taken for arterial CO2 tension measurement. Peritoneal insufflation of CO2 was then commenced and arterial blood samples repeated at 10, 60 and 120 min after CO2 insufflation, and 10 min after the termination of insufflation. During surgery, the PetCO2 was monitored continuously. During the laparoscopic procedure, the intra-abdominal pressure was automatically maintained at 12 mmHg by a CO2 insufflator (Stryker Endoscopy; Roissy Ch. de Gaulle, France). Arterial blood gas analysis was performed using a Nova blood gas analyser (Nova Biomedical, Waltham, MA, USA) after calibration. All patients were placed in a 20° Trendelenburg position with left tilt and then changed to 20° reverse-Trendelenburg position with left tilt during the surgery. Repeated measures ANOVA and t-test were used as appropriate for analysis; P < 0.01 was considered significant.

There were three cases of laparoscopic transanal protosigmoidectomy and 13 cases of laparoscopic low anterior resection. The mean ± SD age of the patients was 51 ± 12 yr, duration of anaesthesia 357 ± 127 min and the first insufflation period 152 ± 70 min. There were significant increases in the mean PetCO2 and PaCO2 during CO2 pneumoperitoneum as compared with before pneumoperitoneum (P < 0.01, Table 1). The P(a−et)CO2 increased significantly with time (P < 0.01, Table 1).

Table 1 Changes in arterial and end-tidal CO2 tension.

Data are expressed as mean ± SD.

*P < 0.01 as compared with preinsufflation value.

CO2 gas is most commonly used in laparoscopic surgery because it is soluble in blood, well diffused into organ tissues, has less risk of gas embolism and has no risk of an explosion. It may cause hypercarbia and respiratory acidosis due to the absorption of CO2 [Reference Fitzgerald, Andrus, Baudendistel, Dahms and Kaminski3]. In healthy patients, however, excess CO2 can be easily washed out by alveolar ventilation, resulting in only mild hypercarbia and an increased etCO2 tension. These studies were reported in relatively short duration of surgery, e.g. laparoscopic cholecystectomy. In our study, the PetCO2 was maintained in the normal range by increasing the minute volume. However, the mean values of PetCO2 during pneumoperitoneum were significantly higher than the PetCO2 before insufflation.

The PaCO2 during pneumoperitoneum, also, was significantly higher than PaCO2 before insufflation. Taura and colleagues [Reference Taura, Lopez and Lacy4] reported the results of arterial blood gas analysis in patients during laparoscopic sigmoidectomy. The mean operation time was 4 h and the PaCO2 at 90 min after insufflation, 5 min before termination of insufflation and at 60 min postoperatively were higher than the baseline.

The P(a−et)CO2 is dependent on many factors including the relative distribution of ventilation and perfusion within the lung, changes in FRC and changes in CO2 production (VCO2). Trendelenburg positioning together with peritoneal insufflation of CO2 during laparoscopy reduces the FRC and increases the VCO2. In addition, there may be a change in the V/Q distribution due to basal lung compression and redistribution of hydrostatic forces. Thus, P(a−et)CO2 may be expected to change. On the contrary, increased FRC may offset decreased pulmonary ventilation due to pneumoperitoneum during reverse-Trendelenburg positioning.

In our study, the P(a−et)CO2 significantly increased during pneumoperitoneum and was highest at 120 min after pneumoperitoneum, as compared with before pneumoperitoneum.

Our results were different from those of Tanaka and colleagues [Reference Tanaka, Satoh, Torii and Suzuki5] who reported that the P(a−et)CO2 increased significantly during pneumoperitoneum during laparoscopic colorectal surgery, but did not increase further even if CO2 insufflation was longer than 60 min. The intra-abdominal pressure was maintained at 7–10 mmHg in their studies whereas in our study it was 12 mmHg. The higher pressure in our study might have been the cause of different results between two studies. In conclusion, during laparoscopic colorectal surgery with prolonged CO2 pneumoperitoneum, PaCO2 should be checked intermittently to confirm adequate ventilation.

References

1.Wittgen, CM, Andrus, CH, Fitzgerald, SD et al. . Analysis of the hemodynamic and ventilatory effects of laparoscopic cholecystectomy. Arch Surg 1991; 126: 9971001.CrossRefGoogle ScholarPubMed
2.Bhavani-Shankar, K, Steinbrook, RA, Brooks, DC, Datta, S. Arterial to end-tidal carbon dioxide pressure difference during laparoscopic surgery in pregnancy. Anesthesiology 2000; 93: 370373.Google Scholar
3.Fitzgerald, SD, Andrus, CH, Baudendistel, LJ, Dahms, TE, Kaminski, DL. Hypercarbia during carbon dioxide pneumoperitoneum. Am J Surg 1992; 163: 186190.CrossRefGoogle ScholarPubMed
4.Taura, P, Lopez, A, Lacy, AM et al. . Prolonged pneumoperitoneum at 15 mmHg causes lactic acidosis. Surg Endosc 1998; 12: 198201.CrossRefGoogle ScholarPubMed
5.Tanaka, T, Satoh, K, Torii, Y, Suzuki, M. Arterial to end-tidal carbon dioxide tension difference during laparoscopic colorectal surgery. Masui 2006; 55: 988991.Google ScholarPubMed
Figure 0

Table 1 Changes in arterial and end-tidal CO2 tension.