Hostname: page-component-78c5997874-lj6df Total loading time: 0 Render date: 2024-11-18T17:20:36.718Z Has data issue: false hasContentIssue false

Stent implantation to ductus arteriosus in a patient with interrupted aortic arch guided by CT image overlay

Published online by Cambridge University Press:  06 March 2017

Sebastian Goreczny*
Affiliation:
Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, Lodz, Poland
Pawel Dryzek
Affiliation:
Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, Lodz, Poland
Tomasz Moszura
Affiliation:
Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, Lodz, Poland
*
Correspondence to: S. Goreczny, MD, PhD, Department of Cardiology, Polish Mother’s Memorial Hospital, Research Institute, Rzgowska Street 281/289, 93-347 Lodz, Poland. Tel: +48 42 271 14 78; Fax: +48 42 271 14 70; E-mail: sebastiangoreczny@yahoo.pl

Abstract

A 15-day-old premature patient with ventricular septal defect and interrupted aortic arch type B underwent “hybrid” initial treatment consisting of bilateral pulmonary artery banding followed by stenting of the ductus arteriosus. A pre-registered CT scan was re-purposed with a new three-dimensional image fusion software (VesselNavigator) to create a roadmap for stent delivery.

Type
Brief Report
Copyright
© Cambridge University Press 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Goreczny, S, Qureshi, S, Rosenthal, E, et al. Self-expanding stent implantation in arterial duct during hybrid palliation of hypoplastic left heart syndrome: midterm experience with a specially designed stent. EuroIntervention 2015; 10: 13181325.CrossRefGoogle ScholarPubMed
2. Moszura, T, Dryzek, P, Goreczny, S, et al. A 10-year single-centre experience in percutaneous interventions for multi-stage treatment of hypoplastic left heart syndrome. Cardiol Young 2014; 24: 5463.CrossRefGoogle ScholarPubMed
3. Goreczny, S, Morgan, GJ, Dryzek, P. Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size. Cardiol Young 2016; 26: 605608.CrossRefGoogle ScholarPubMed
4. Goreczny, S, Dryzek, P, Moszura, T. Novel 3-dimensional image fusion software for live guidance of percutaneous pulmonary valve implantation. Circ Cardiovasc Interv 2016; 9: e003711.CrossRefGoogle ScholarPubMed
5. Stangenberg, L, Shuja, F, Carelsen, B, et al. A novel tool for three-dimensional roadmapping reduces radiation exposure and contrast agent dose in complex endovascular interventions. J Vasc Surg 2015; 62: 448455.Google Scholar

Goreczny supplementary material

Video 1

Download Goreczny supplementary material(Video)
Video 15.6 MB