Edwards Inspiris Resilia® valve for mitral replacement in an infant after mechanical valve failure

Part of: Surgery

Published online by Cambridge University Press:  03 December 2018

Radoslaw Jaworski*
Affiliation:
Department for Pediatric Cardiothoracic Surgery, Children’s Memorial Health Institute, Warsaw, Poland
Andrzej Kansy
Affiliation:
Department for Pediatric Cardiothoracic Surgery, Children’s Memorial Health Institute, Warsaw, Poland
Mariusz Birbach
Affiliation:
Department for Pediatric Cardiothoracic Surgery, Children’s Memorial Health Institute, Warsaw, Poland
Anna Brodzikowska-Pytel
Affiliation:
Department for Cardiology, Children’s Memorial Health Institute, Warsaw, Poland
Monika Kowalczyk-Domagala
Affiliation:
Department for Cardiology, Children’s Memorial Health Institute, Warsaw, Poland
Grazyna Brzezinska-Rajszys
Affiliation:
Department for Cardiology, Children’s Memorial Health Institute, Warsaw, Poland
Bohdan Maruszewski
Affiliation:
Department for Pediatric Cardiothoracic Surgery, Children’s Memorial Health Institute, Warsaw, Poland
*
Author for correspondence: R. Jaworski, MD, PhD, Department for Pediatric Cardiothoracic Surgery, Children’s Memorial Health Institute, Al. Dzieci Polskich 20, Warsaw 04-730, Poland. Tel: +48 22 815 73 46; Fax: +48 22 815 73 40; E-mail: radicis@go2.pl

Abstract

We present the surgical implantation of the Edwards Inspiris Resilia® aortic valve in mitral position for mechanical mitral valve failure in a severely ill infant after valve replacement because of anomalous origin of the left coronary artery from the pulmonary artery. The biological valve was chosen because the child could not receive oral anticoagulation and was for several months on heparin infusion. The procedure was safely performed with good haemodynamic result.

Type
Brief Report
Copyright
© Cambridge University Press 2018 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Cite this article: Jaworski R, Kansy A, Birbach M, Brodzikowska-Pytel A, Kowalczyk-Domagala M, Brzezinska-Rajszys G, Maruszewski B. (2018) Edwards Inspiris Resilia® valve for mitral replacement in an infant after mechanical valve failure. Cardiology in the Young. page 219 of 221. doi: 10.1017/S1047951118001816

References

1. Sawan, EB, Brink, J, Soquet, J, et al. The ordeal of left atrioventricular valve replacement in children under 1 year of age. Interact Cardiovasc Thorac Surg 2017; 25: 317322.Google Scholar
2. Trezzi, M, Cetrano, E, Iacobelli, R, Carotti, A. Edwards Sapien 3 valve for mitral replacement in a child after melody valve endocarditis. Ann Thorac Surg 2017; 104: e429e430.Google Scholar
3. Alexi-Meskishvili, V, Nasseri, BA, Nordmeyer, S, et al. Repair of anomalous origin of the left coronary artery from the pulmonary artery in infants and children. J Thorac Cardiovasc Surg 2011; 142: 868874.Google Scholar
4. Beierlein, W, Becker, V, Yates, R, et al. Long-term follow-up after mitral valve replacement in childhood: poor event-free survival in the young child. Eur J Cardiothorac Surg 2007; 31: 860865.10.1016/j.ejcts.2007.02.006Google Scholar
5. Abdullah, I, Ramirez, FB, McElhinney, DB, Lock, JE, del Nido, PJ, Emani, S. Modification of a stented bovine jugular vein conduit (melody valve) for surgical mitral valve replacement. Ann Thorac Surg 2012; 94: e97e98.Google Scholar
6. Athanasiou, T, Cherian, A, Ross, D. The Ross II procedure: pulmonary autograft in the mitral position. Ann Thorac Surg 2004; 78: 14891495.10.1016/j.athoracsur.2004.02.074Google Scholar
7. Haponiuk, I, Chojnicki, M, Jaworski, R, et al. Paediatric Melody® mitral valve replacement in acute endocarditis – alternative surgical-hybrid technique. Kardiol Pol 2017; 75: 845849.10.5603/KP.a2017.0092Google Scholar
8. Quiñonez, LG, Breitbart, R, Tworetsky, W, Lock, JE, Marshall, AC, Emani, SM. Stented bovine jugular vein graft (Melody valve) for surgical mitral valve replacement in infants and children. J Thorac Cardiovasc Surg 2014; 148: 14431449.10.1016/j.jtcvs.2013.10.059Google Scholar
9. Edwards Inspiris Resilia® valve manufacturer information. Available at https://www.edwards.com/gb/devices/heart-valves/resilia. Accessed July 8, 2018.Google Scholar

Jaworski et al. supplementary material

Jaworski et al. supplementary material 1

Download Jaworski et al. supplementary material(Video)
Video 3.6 MB

Jaworski et al. supplementary material

Jaworski et al. supplementary material 2

Download Jaworski et al. supplementary material(Video)
Video 2.2 MB

Jaworski et al. supplementary material

Jaworski et al. supplementary material 3

Download Jaworski et al. supplementary material(Video)
Video 2.2 MB